170 likes | 197 Views
Expand the lifespan of your batteries: lead sulfate is removed by the electrical high-frequency pulsation process of the battery reconditioner. Rejuvenate your battery!
E N D
Battery Regeneration Revival Battery Clinic++ Solution
1) Do you want to save your battery life ? 2) Do you want to save your money ? 3) Do you want to save our earth ? 4) Do you want to save our next generation ? 5) Do you want to go green ?
Introduction As many as 70% to 80% of lead-acid batteries are replaced prematurely due to the sulphation that occurs on lead plates regardless of maintenance. Sulphation is an electrochemical reaction that occurs when a battery is discharged. During normal use or in storage, a battery’s sulfuric acid is active between the plates. This reaction creates energy in the form of electric current. It also transforms the acid’s chemical composition that is in contact with the lead plates, forming a solid residue (lead sulfate). This continual sulfate accumulation accelerates the weakening process and finally “suffocates” the battery.
EFFECTS OF SULPHATION Sulphated Plate Sulphation reduces the electrolyte concentration – Thus the cell voltage is also reduced. As sulphation increases, the internal resistance increases – Added heat generation produces a marked rise in temperature. These higher temperature further accelerates in dry- out processes – culminates in the early failure of a battery. Cont….
General lack of capacity (deliverable power). An increase in battery temperature while charging or discharging. A strong odor of hydrogen gas while charging or discharging. An excessive use of water and a rapid rise in battery voltage while charging (stops the charger).
HOW TO REDUCE SULPHATION ?... HOW TO REDUCE SULPHATION ?... Following recommended battery maintenance procedures may keep your batteries operational for the typical 5 to 7 years of standard battery life. The earlier you treat a battery, the better. The battery will maintain its health and will have an even longer service life. The newer the battery, the more likely you can double, triple or even quadruple its expected service life. Note – the battery must be functional. Physically damaged batteries or batteries with dead cells cannot be treated with our process. Battery regeneration is a procedure that returns a sulfated battery to its original and normal condition. REVIVAL Battery Clinic ++ regenerates sulphated batteries utilizing an electro-chemical sulphation reversion process.
How REVIVAL Battery Clinic ++ REVIVAL Battery Clinic ++ works ?... Sulphation of the internal plates rises resistance in the battery making it impossible to work to its full potential. Our REVIVAL Battery Clinic ++ Regenerator successfully reverse the sulphation process, converting lead sulphate crystals back into active matters by applying a very high frequency pulse in several steps. This process restores battery capacity, giving you the ability to still use old and sulphated batteries and extend the life of your energy assets. REVIVAL Battery Clinic ++ cleans and maintains battery plates and separators by dissolving lead sulfate crystals. During the de-sulphation treatment, the sulphate residue melts slowly and progressively returning to the battery’s acid.
REVIVAL Battery Clinic ++ restores the battery plate composition and improves performance allowing the battery to operate at its optimum capacity, often well beyond its original specifications. REVIVAL Battery Clinic ++ “Regenerator" uses cutting edge technology to send a specially controlled pulsing DC current into the battery. The current pulses convert battery-killing sulphate crystals back to liquid molecules in the electrolyte. The battery stays in top condition and its lifespan is dramatically extended.
WHY REVIVAL Battery Clinic ++ WHY REVIVAL Battery Clinic ++ ?... ?... Reduces the capital and operational expenditure. Improves battery performance and efficiency. Reduces charging time and increases working time between charging. Increase in the workers productivity. Reduction of electric consumption. Increase of Life Expectancy shifts from an average of 4 to 8 years, ensuring the battery capacity > 70% during the 8 years. Most professional piece of technology available in today's market to service batteries: multi voltage, multi chemistry, Discharging, charging, bad cell detection, software, reports.... Process from finish to start maximum 30-40 hours and a fully detailed report in pdf, word or excelon the results.
REVIVAL Battery Clinic ++ has become the dedicated brand name of Revival Engineers specialized in battery regeneration with many happy and returning customers. Our REVIVAL Battery Clinic ++ is specifically designed to analyze and regenerate all types of lead acid batteries; we have very nice references in different industry sectors. Regeneration is very popular and becomes a real asset management tool because 80 percent of the batteries breaking down and losing capacity are sulphated and can be restored with the right treatment. Our REVIVAL Battery Clinic ++ can also be used for annual maintenance which strongly extends the lifespan of the batteries. With our Repulse technology we can do what others cannot provide: to prove the results after regeneration.
The Process REVIVAL Battery Clinic ++ equipment is a combo of a regenerator and discharger . The voltage, current, time and temperature are all monitored throughout the whole process and the data can be transferred wireless to your computer. With this data, a full report on the battery’s condition can be made with our software. The regeneration process should be started with a fully charged battery. Our REVIVAL Battery Clinic ++ regenerates the battery in several steps. Starting with a discharge, followed by regeneration, equalization, another discharge and ending with another regeneration mode.
After the whole process the data of Discharge 1 and 4 can be compared, making it easy to see the difference in capacity and internal resistance of the battery before and after. (Please take a look at the added file called “Results Regeneration” for more info on how to analyze the results). We even go one step further. If combined with our optional Battery Monitoring System, we are capable of detecting which cell in your battery bank is the one causing the battery to run down too fast. The BMS system permits to monitor the voltage of each individual cell every three minutes during charge and discharge. This is giving you the ability to make a full analysis of the battery up to cell level. The measurements are stored fully automatic, which means the regenerator and BMS work autonomously and do not have to be supervised while regenerating a battery.
Before After
Regenerating batteries keeps them out of the landfill… So our planet stays greener!