1 / 32

A Second Look at Striping

A Second Look at Striping. Stan Kidder 5 Oct 2012. Methodology. VIIRS SDR radiances were examined on two dates, 9 April 2012 and 29 September 2012 Examined the middle 37% of the elements (which are not subject to bow-tie deletions)

josef
Download Presentation

A Second Look at Striping

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A Second Look at Striping Stan Kidder 5 Oct 2012

  2. Methodology • VIIRS SDR radiances were examined on two dates, 9 April 2012 and 29 September 2012 • Examined the middle 37% of the elements (which are not subject to bow-tie deletions) • Examined 22 granules (1056 scans) on 9 April and 25 granules (1200 scans) on 29 September near CONUS and near 1330 local time • For each band, the mean radiance for each scan line minus the overall mean radiance was divided by an estimate of noise for each band. This is called the Normalized Deviation.

  3. Noise (Estimated from measured SNR or NEDT)

  4. Range (max – min)of Normalized Deviations

  5. M6 Range of Normalized Deviations Black = saturation?

  6. M13 Odd- and even-line striping Range of Normalized Deviations Range of data may mask striping in this image

  7. M10 Range of Normalized Deviations

  8. M3 Range of Normalized Deviations

  9. M7 Range of Normalized Deviations

  10. M1 Range of Normalized Deviations

  11. M2 Range of Normalized Deviations

  12. M8 Range of Normalized Deviations

  13. M4 Range of Normalized Deviations

  14. M5 Range of Normalized Deviations

  15. M12 Odd- and even-line striping Range of Normalized Deviations

  16. I3 Range of Normalized Deviations

  17. I1 Range of Normalized Deviations

  18. I2 Range of Normalized Deviations

  19. M15 Odd- and even-line striping Range of Normalized Deviations

  20. M16 Range of Normalized Deviations

  21. I4 Odd- and even-line striping Range of Normalized Deviations

  22. M14 Range of Normalized Deviations

  23. M11 Range of Normalized Deviations

  24. I5 Odd- and even-line striping Range of Normalized Deviations

  25. M9 Range of Normalized Deviations

  26. Conclusions (1/2) • Results are similar in April and September cases. • The M6 striping is smaller in September than it was in April, but is still very large. Also, there appear to be saturation issues. • Some channels seem to have odd- and even-line striping. • Some of the differences between September and April may be caused by real scene effects.

  27. Conclusions (2/2) • Comparing with noise is interesting and useful, but whether or not one can see striping depends on the magnitude of striping in comparison with the range of data in a scene. It is difficult to see any evidence of striping in the M13 image, for example, even though statistically M13 has the second largest striping (compared to noise).

  28. From previous study Backup Slides

  29. I1  0.64mm Very small deviation from Block Mean Radiance No noticeable striping Highly Enhanced Image

  30. M6 – 0.747 m Very Large Striping Unenhanced Image

  31. M13 – 4.05 m Moderate deviations from Block Mean Radiance, but hard to find striping

  32. M10 – 1.61 m Moderate deviations—some striping visible in unenhanced image

More Related