Dupline introduction

Dupline introduction. Dupline introduction. Hierarchy structure for “Industrial Automation”. Net. Plant. Plant. Computer. Prod. Level. Prod. Comp. Process Level. PC's, SCADA. PLC's. Device Level. Dupline. Component Level. Counters, Timers, Drives.

juliet
Download Presentation

Dupline introduction

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Dupline introduction

  2. Dupline introduction Hierarchy structure for “Industrial Automation” Net Plant Plant Computer Prod. Level Prod. Comp. Process Level PC's, SCADA PLC's Device Level Dupline Component Level Counters, Timers, Drives Sensors, Switches, Relays, Valves, Motors

  3. A1 A2 A4 A3 A2 Transceiver A4 A1 A3 A1 A4 A3 A3 A2 Channel Generator FMK 8 Channel Generator Transceiver A1 A2 A4 Dupline introduction How the system operates

  4. Cabling Master Generator Carlo Gavazzi Sender C1 C2 Dupline introduction

  5. Netz Master Generator Carlo Gavazzi Sender C1 C2 A1 A1 A1 A5 A5 A5 Receiver Carlo Gavazzi A1 A5 Dupline introduction x-numbers of push buttons can control one or more outputs

  6. Netz A1 A5 Receiver Carlo Gavazzi A1 A5 Master Generator Carlo Gavazzi Sender C1 Receiver Carlo Gavazzi A1 A5 C2 A1 A5 Receiver Carlo Gavazzi Dupline introduction One or more push buttons can control x-numbers of outputs

  7. Programing of smart-house

  8. V 8.2 2.2 t Synk. 128 pulser 8 ms 128 x 1 ms 136 ms Dupline introduktion Puls Train

  9. Carlo Gavazzi Master Generator Sender 8.2 8.2 2.2 2.2 Function 0 0 t t CONFIGURATION .75 ms .5 ms .5 ms .25 ms Input Output Split I/O Dupline introduktion

  10. B3 B1 B4 B2 Receiver Carlo Gavazzi Master Generator Carlo Gavazzi Sender C1 B2 B1 B4 B3 C2

  11. 16 groups with 8 channels in each Groups : A to P ( A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P) Channels : 1 to 8 (1, 2, 3, 4, 5, 6, 7, 8) I/O addresses: A1, A2, ... C5, ... P8 Dupline introduktion Addressing

  12. Windows configuration

  13. Dupline CARLO GAVAZZI ASIC Progammer GAP 1605 1 2 3 4 5 6 7 8 In/Out A B C D E F G H Group I J K L M N O P Channel 1 2 3 4 5 6 7 8 Read/On Prog 8 adresser

  14. Reading 2) READ IN DISPLAY Dupline CARLO GAVAZZI ASIC Progammer GAP 1605 In/Out 1 1 2 3 4 5 6 7 8 In/Out Group C A B C D E F G H Group I J K L M N O P Channel Channel 2 1 2 3 4 5 6 7 8 Read/On Prog 1) Turns ON Input or output 1 is addressed to C2

  15. New address Dupline CARLO GAVAZZI ASIC Progammer GAP 1605 1 2 3 4 5 6 7 8 2) Select IN/OUT In/Out A B C D E F G H 3) Select Group Group I J K L M N O P 4) Select Channel Channel 1 2 3 4 5 6 7 8 Read/On Prog 1) Turn ON 5) Press “Prog”

  16. 8 addresses Dupline CARLO GAVAZZI ASIC Progammer GAP 1605 1 2 3 4 5 6 7 8 In/Out A B C D E F G H Group I J K L M N O P Channel 1 2 3 4 5 6 7 8 Read/On Prog

  17. Programing of OPUS/FUGA New addresses Dupline CARLO GAVAZZI ASIC Progammer 5) Go to next in/output (continue from 2) GAP 1605 1 2 3 4 5 6 7 8 2) Select In/Output In/Out A B C D E F G H 3) Select group Group I J K L M N O P Channel 4) Select channal 1 2 3 4 5 6 7 8 Read/On Prog 1) Turn ON 6) Push “Prog” (Programming of the addresses can wait until the last in/output address have been selected)

  18. Dupline CARLO GAVAZZI ASIC Progammer GAP 1605 1 2 3 4 5 6 7 8 In/Out 1 2 3 4 5 6 7 8 /Out A B C D E F G H Group OPUS I J K L M N O P Channel 1 2 3 4 5 6 7 8 FUGA Read/On Prog 1 2 3 4 5 6 7 8 In/ 5) Go to next in/output (continue from 2) 2) Select In/Output 3) Select group 4) Select channal 1) Turn ON IN/OUT placement of OPUS/FUGA 6) Push “Prog” (Programming of the addresses can wait until the last in/output address have been selected)

  19. Dupline test unit GTU 8

  20. MODE: DIGITAL 1 GROUP 1 3 7 8 Display of the status of a chosen channel group Dupline Test Unit GTU 8 Show the channel status A 1 - 3 - -- - 8 Enter Mode Select Channel group 7 8 Activates the channel ON 4 5 6 2 3 1

  21. El-installations principper Fra parallel fortrådning til

  22. Installation med kabel • Fordele • Billigt og hurtigt installationsprincip • Bus i hele installationen • Største forsyningskapacitet af busforsynede komponenter • Ulemper • Vanskelig montage af bus i tryk 1,5 • Stærk- og svagstrøm fremføres sammen • Vanskelig at udvide med ekstra ledninger 25

  23. Installation med kabel, bus i separat svagstrømskabel • Fordele • Billigt og hurtigt installationsprincip • Nem montage af tryk 0,5 • Adskilt stærk- og svagstrøm • Ulemper • Ikke bus i hele installationen • Lille forsyningskapacitet (ved brug af lille kvadrat) • Vanskelig at udvide med ekstra ledninger 26

  24. Fordele Bus i 0,5 giver synlig forskel på ledningerne Bus i hele installationen Nem montage af tryk 0,5 Nem udvidelse af installationen Stor forsyningskapacitet af busforsynede komponenter Rørinstallation med PVL-ledning • Ulemper • Prisen på installationen • Stærk- og svagstrøm fremføres sammen 27

  25. Dupline Smart-house princip

  26. Dupline Smart-house princip

  27. 100 % Decentralt koncept

More Related