Prediction of Corneal Permeability

Prediction of Corneal Permeability. David Kim Allergan Inc. SoCalBSI California State University, Los Angeles. Objective. Develop a model to predict corneal permeability based on literature compounds. Introduction. Ocular drug delivery mechanism (through cornea and/or conjunctiva)

kalil
Download Presentation

Prediction of Corneal Permeability

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Prediction of Corneal Permeability David Kim Allergan Inc. SoCalBSI California State University, Los Angeles

  2. Objective • Develop a model to predict corneal permeability based on literature compounds

  3. Introduction • Ocular drug delivery mechanism (through cornea and/or conjunctiva) • Focus of the project is the corneal route

  4. Three major cell layers of the Cornea

  5. Why predict corneal permeability? • Allergan, Inc. develops drugs which are administered through the eye • A drug is only effective if it can reach its target tissue • Can save company time and money in determining if the drug can pass through the cornea before the drug is synthesized

  6. Introduction • Few models have been developed to predict corneal permeability • Congeneric model (one class of compounds) • Non-congeneric model (mutiple class of compounds) • Develop non-congeneric model focused on drug-like compounds

  7. Literature • Compound names • logPC and logD • structure of compounds Generate descriptor values Filter descriptors (intuitively) Find optimal training and testing set percentage Run Partial Least Squares modeling Statistical analysis Pick best model Final Model Remove descriptor with the lowest importance Rebuild model

  8. Log PC = log of the Permeability Coefficient (cm/s) Partition Coefficient: Log D = log of the Distribution Coefficient (pH 7.65) Yoshida, F., Topliss, J.G., J. Pharm. Sci. 85, 819-823 (1996)

  9. Yoshida, F., Topliss, J.G., J. Pharm. Sci. 85, 819-823 (1996)

  10. Compounds in Literature • Went through published literature • Filtered compounds to look only for drug like compounds • Came up with 30 compounds and their measured permeability • Next step in our model building process is to produce descriptors for each of our compounds

  11. Descriptors • Molecular weight or volume • Degree of ionization • Aqueous solubility • Hydrogen-bonding • Log D • Polar surface area (PSA) • pKa • Solvent accessible surface area

  12. Schrödinger Software • Named after Erwin Schrödinger –Nobel prize winner for the Schrödinger equation which deals with quantum mechanics • Suite of various programs dealing with computational chemistry • Two programs used: • Maestro – calculate descriptor values • Canvas – generate model

  13. Maestro Program

  14. Maestro Program • Can generate 77 descriptors • Can manually input descriptors (eg. log D) • Filtered descriptors which do not deal with permeability (intuitively) to reduce noise • Came up with 30 descriptors to use • Export the 30 compounds and its 30 descriptors to Canvas

  15. Canvas Program

  16. Canvas Program • Partial Least Squares (PLS) modeling • Can specify what descriptors to use to build the model • Can specify the compounds used for training and testing the model • Model assessment: corresponding statistics of the model

  17. Statistics • Training Set • Standard deviation (SD) – low • Coefficient of determination (R2) – high close to 1 • Coefficient of determination, cross validation (R2-CV) – high close to 1 • Stability – close to 1 • F-statistic (overall significance of the model) – high • P-value (probability that correlation happened by chance) – low <0.01

  18. Statistics • Testing Set • Root Mean Squared Error (RMSE) – low • Q2 – high close to 1 • Pearson correlation coefficient (r-Pearson) – high close to 1 • Important for the assessment of what percentage of the compounds we want to use for the training set • Important for the assessment of our model as we start to remove unnecessary descriptors

  19. Finding the ideal training set percentage • Ran PLS modeling specifying various percentages to use for the training set • 40%, 50%, 60%, 70%, 80% • Looked at the statistics of each of the models built • Found that using 80% of the compounds for the training set was ideal • 30 compounds found in literature • 24 in training set and 6 in the testing set

  20. bx coefficient • After the PLS model is built, it gives the bx coefficient for each descriptor in order to predict permeability • The bx coefficient is the weight that the model puts on the descriptor after the descriptor values have been scaled Example: log PC = 0.348(scaled MW) –0.221(scaled log D) -0.002(scaled log P)……

  21. Removal of descriptors • Started with 30 descriptors and built a model • Identified the descriptor with the lowest bx coefficient and removed it • Rebuilt model with 29 descriptors • Repeat…. while keeping track of the statistics • Want to keep track of statistics to know when to stop Example: log PC = 0.348(scaled MW) –0.221(scaled log D) -0.002(scaled log P)………….(30) log PC = 0.392(scaled MW) –0.183(scaled log D)……………………………….………….(29)

  22. Training Statistics Test Statistics

  23. Remaining 8 Descriptors • CIQPlogS – conformation independent predicted aqueous solubility • QPlogS - predicted aqueous solubility • FOSA – hydrophobic component of the total solvent accessible surface area • PISA -  (carbon and attached hydrogen) component of the total solvent accessible surface area

  24. Remaining 8 Descriptors • QPlogKp - predicted skin permeability • QPlogBB – predicted blood/brain partition coefficient • donorHB - Estimated number of hydrogen bonds that would be donated by the solute to water molecules in an aqueous solution • log D – Distribution coefficient

  25. Permeability Model Function log PC = -0.1371(scaledCIQPlogS ) - 0.1383(scaledFOSA) + 0.1792(scaledPISA) + 0.1558(scaledQPlogBB) + 0.2815(scaledQPlogKp) - 0.1451(scaledQPlogS) - 0.2242(scaleddonorHB) + 0.2646(scaledlogD) SD = 0.460791 R2 = 0.814213 F = 46.0162 (p < 0.0000001)

  26. Predicted vs Observed Permeability

  27. Conclusion • Successfully created a model to predict the corneal permeability of compounds • Showed that the Schrödinger software generates significant descriptors to build a permeability model

  28. Potential Future Work • Apply the model to external training set to asses its predictability power • Build a more refined model with more compounds • Find other descriptors other than the ones generated by Maestro and use them in the model building

  29. Acknowledgments • Dr. Ping Du • Dr. Chungping Yu • Pushpa Chandrasekar • Noeris Salem • Allergan • SoCalBSI