Conclusions and empirical data from the first large scale public field trial of building mounted micro-wind turbines. Helen Brown. +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK. 19 th March 2009. Warwick Wind Trials. Agenda. Objectives and background
E N D
Conclusions and empirical data from the first large scale public field trial of building mounted micro-wind turbines Helen Brown +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Agenda • Objectives and background • Methods and scope • Data analysis • Wind speeds • Scaling factors • Energy • Power curves • Conclusions +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Objectives and backgroundWhy did we do this? Encraft is a low carbon technology consultancy established to accelerate the creation of an accessible mass market for microgeneration technologies in the UK consultancy – software and design tools – project engineering Over 500 projects since 2003 Independent and impartial Informed customers are the key +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Objectives and backgroundFunders • Turbine owners • Formal sponsors • Supporters • Data customers Sponsors Supporters +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Methods and scopeSites +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Methods and scopeTurbines Ampair 600 Air Dolphin Z1000 StealthGen D400 Windsave WS1200 Swift +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Methods and scopeInstrumentation • PEET Kit • Meteo Anemometer • Novus Logbox DA • Iskrameco ME162 Watt meter • BRE Kit • NRG Anemometer • Pace Scientific XR5-SE • Iskrameco ME162 Watt meter +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisFundamentals The fundamental question from a customer perspective is... How accurately can we predict output from building mounted micro-wind turbines? +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisFundamentals +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisWind speeds +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisWind speeds • Measured average wind speed is >40% lower than NOABL prediction at 16 sites • Weibull shape factor is less than 1.6 at 18 sites +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisScaling factors • MIS 3003 – scaling for annual average wind speed • Encraft scheme – scaling for wind speed and “k” +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisFundamentals +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisEnergy Lillington Road (domestic property in built up area) Turbine: Ampair 600 +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisEnergy Birds Hill (domestic property in built up area) Turbine: Eclectic StealthGen D400 +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisPower curves West Staddon (domestic property in rural area) Turbine: Windsave WS1200 +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisPower curves Eden Court 2 (isolated, high rise block of flats) Turbine: Ampair 600 +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Data analysisEnergy • Average energy exported per day per turbine • 628 Wh (only including times when turbines were switched on) • 214 Wh (including times when turbines were broken or switched off for maintenance) • Average energy consumed per day per turbine • 80 Wh +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
Conclusions • Great care should be taken in selecting suitable sites for building-mounted turbines. • Scaling factors for NOABL and the Weibull shape factor may improve wind speed predictions although more work is required in this area. • Our data shows the (now recognised) need for an industry standard that normalises the way in which manufacturers’ power curves are produced and this data should be published. +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials
www.warwickwindtrials.org.uk +441926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK 19th March 2009 Warwick Wind Trials