César Domingo Pardo GSI Helmholtzzentrum für Schwerionenforschung GmbH

Status of AGATA@GSI and Expected Performance. César Domingo Pardo GSI Helmholtzzentrum für Schwerionenforschung GmbH. AGATA ISTANBUL WORKSHOP 5.5.2010. Outline. Summary of the Meeting on AGATA@GSI setup (30.4.2010)

keanu
Download Presentation

César Domingo Pardo GSI Helmholtzzentrum für Schwerionenforschung GmbH

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status of AGATA@GSI and Expected Performance César Domingo Pardo GSI Helmholtzzentrum für Schwerionenforschung GmbH AGATA ISTANBUL WORKSHOP 5.5.2010

  2. Outline • Summary of the Meeting on AGATA@GSI setup (30.4.2010) • AGATA Geometry for experiments at GSI FRS (PRESPEC) • Performance in terms of efficiency and resolution • Angular dependence of the g-ray efficiency for several distances • Relativistic dependence of the efficiency on b • Performance vs. number of double and/or triple cluster available • Efficiency performance for pure E2 transitions • MC Simulation of a Fragmentation experiment • MC Simulation of the line-shape for DSAM analysis • First steps towards implementation of background in the simulations • Outlook • Conclusion

  3. Summary on the AGATA@GSI Meeting on set-up, detectors and mechanics, 30.4.2010 Set-up at the FRS final focal plane (S4): RIB beam

  4. Summary on the AGATA@GSI Meeting on set-up, detectors and mechanics, 30.4.2010 Set-up at the FRS final focal plane (S4): Chamber RIB beam Sec. Target + DSSD + Plastic TOF Start

  5. Summary on the AGATA@GSI Meeting on set-up, detectors and mechanics, 30.4.2010 Set-up at the FRS final focal plane (S4): Chamber RIB beam Liquid Hydrogen Target

  6. Summary on the AGATA@GSI Meeting on set-up, detectors and mechanics, 30.4.2010 Set-up at the FRS final focal plane (S4): Chamber RIB beam Plunger + DSSD + Plastic TOF Start

  7. Summary on the AGATA@GSI Meeting on set-up, detectors and mechanics, 30.4.2010 Set-up at the FRS final focal plane (S4): Chamber RIB beam Sec. Target + DSSD + Plastic TOF Start

  8. Summary on the AGATA@GSI Meeting on set-up, detectors and mechanics, 30.4.2010 Set-up at the FRS final focal plane (S4): Chamber RIB beam LYCCA Products Sec. Target + DSSD + Plastic TOF Start

  9. Summary on the AGATA@GSI Meeting on set-up, detectors and mechanics, 30.4.2010 Set-up at the FRS final focal plane (S4): AGATA Chamber RIB beam LYCCA Products Sec. Target + DSSD + Plastic TOF Start

  10. Summary on the AGATA@GSI Meeting on set-up, detectors and mechanics, 30.4.2010 Set-up at the FRS final focal plane (S4): AGATA Chamber RIB beam LYCCA Products +/- 15 cm Sec. Target + DSSD + Plastic TOF Start

  11. Summary on the AGATA@GSI Meeting on set-up, detectors and mechanics, 30.4.2010 Set-up at the FRS final focal plane (S4): HECTOR AGATA Chamber RIB beam LYCCA Products Sec. Target + DSSD + Plastic TOF Start

  12. Summary on the AGATA@GSI Meeting on set-up, detectors and mechanics, 30.4.2010 Set-up at the FRS final focal plane (S4): HECTOR AGATA Chamber RIB beam LYCCA Products Sec. Target + DSSD + Plastic TOF Start

  13. AGATA S2' = 10 ATC + 5 Double Cluster Detectors Geometry cases • S2 + 5 Double Cluster detectors closing part of the central hole (15-16cm?). Remains shell with 5 crystals hole + pentagon hole AGATA S2' Geometry AGATA S2 Geometry = + 10 triple Cluster + 5double Cluster

  14. AGATA S2' = 10 ATC + 5 Double Cluster Detectors Geometry cases • S2 + 5 Double Cluster detectors closing part of the central hole (15-16cm?). Remains shell with 5 crystals hole + pentagon hole Beam pipe diameter = 9 - 12 cm

  15. AGATA S2' = 10 ATC + 5 Double Cluster Detectors beam

  16. AGATA S2' = 10 ATC + 5 Double Cluster Detectors beam Blue crystals are at diameter = 17 cm Room for a chamber 46cm diameter

  17. AGATA S2' = 10 ATC + 5 Double Cluster Detectors • S2’ Geometry + Spherical Chamber 46 cm

  18. Outline • AGATA Geometry for experiments at GSI FRS (PRESPEC) • Performance in terms of efficiency and resolution • Angular dependence of the g-ray efficiency for several distances • Relativistic dependence of the efficiency on b • Performance vs. number of double and/or triple cluster available • Efficiency performance for pure E2 transitions • MC Simulation of a Fragmentation experiment • MC Simulation of the line-shape for DSAM analysis • First steps towards implementation of background in the simulations • Outlook • Conclusion

  19. Performance comparison: general aspects • Systematic study of efficiency and resolution vs. distance for all geometries • “Reference physics case”: (GEANT4 AGATA code from E.Farnea et al.) Eg,o = 1 MeV, recoil nucleus at b = 0.43 (E = 100 MeV/u), Mg = 1 Systematic study several distances sec. target – detector Detector Target Beam distance distance GSI FRS Spatial Beam Profile FWHMx = 6 cm FWHMy = 4 cm Active target DSSSD

  20. S-Geometries Performance comparison: Efficiency S1 S1 S2’ S3 S2’ S3’ S2 S2 S3’ S1 S3 S2’ S3 S3’ S2

  21. S-Geometries Performance comparison: Resolution S1 S1 S3 S3’ S2’ S2 S2’ S2 r = 5 mm (fwhm) S3’ S1 S3 S3’ S3 S2 S2’ r = 2 mm (fwhm)

  22. Shell Geometries performance comparison: Summary S1 r = 5 mm S2’ S2 -Eff. (%) -Sensitivity (Rising Units) S3’ -Eff. (%) FWHM (keV) r = 2 mm S3

  23. AGATA S2' Performance Summary Geometry cases • S2 + 5 Double Cluster detectors closing part of the central hole (15-16cm?). Remains shell with 5 crystals hole + pentagon hole Beam pipe diameter = 12 cm g-EFFICIENCY gg-EFFICIENCY RESOLUTION

  24. Outline • AGATA Geometry for experiments at GSI FRS (PRESPEC) • Performance in terms of efficiency and resolution • Angular dependence of the g-ray efficiency for several distances • Relativistic dependence of the efficiency on b • Performance vs. number of double and/or triple cluster available • Efficiency performance for pure E2 transitions • MC Simulation of a Fragmentation experiment • MC Simulation of the line-shape for DSAM analysis • First steps towards implementation of background in the simulations • Outlook • Conclusion

  25. AGATA S2' @ GSI: angular dependence of the efficiency

  26. Outline • AGATA Geometry for experiments at GSI FRS (PRESPEC) • Performance in terms of efficiency and resolution • Angular dependence of the g-ray efficiency for several distances • Relativistic dependence of the efficiency on b • Performance vs. number of double and/or triple cluster available • Efficiency performance for pure E2 transitions • MC Simulation of a Fragmentation experiment • MC Simulation of the line-shape for DSAM analysis • First steps towards implementation of background in the simulations • Outlook • Conclusion

  27. AGATA S2' @ GSI: relativistic dependence of the efficiency b = 0.43 b = 0

  28. Outline • AGATA Geometry for experiments at GSI FRS (PRESPEC) • Performance in terms of efficiency and resolution • Angular dependence of the g-ray efficiency for several distances • Relativistic dependence of the efficiency on b • Performance vs. number of double and/or triple cluster available • Efficiency performance for pure E2 transitions • MC Simulation of a Fragmentation experiment • MC Simulation of the line-shape for DSAM analysis • First steps towards implementation of background in the simulations • Outlook • Conclusion

  29. AGATA S2' @ GSI: efficiency vs. # triple (double) clusters S2’ Configuration = 10 ATC + 5 ADC ATC (Agata Triple Cluster) ADC (Agata Double Cluster)

  30. AGATA S2' @ GSI: efficiency vs. # triple (double) clusters S2’ Configuration = 10 ATC + 5 ADC ATC (Agata Triple Cluster) ADC (Agata Double Cluster)

  31. AGATA S2' @ GSI: efficiency vs. # triple (double) clusters S2’ Configuration = 10 ATC + 5 ADC ATC (Agata Triple Cluster) ADC (Agata Double Cluster)

  32. AGATA S2' @ GSI: efficiency vs. # triple (double) clusters S2’ Configuration = 10 ATC + 5 ADC ATC (Agata Triple Cluster) ADC (Agata Double Cluster)

  33. AGATA S2' @ GSI: efficiency vs. # triple (double) clusters S2’ Configuration = 10 ATC + 5 ADC ATC (Agata Triple Cluster) ADC (Agata Double Cluster)

  34. AGATA S2' @ GSI: efficiency vs. # triple (double) clusters Dependence of the efficiency on the number of triple (double) clusters • In the "high-efficiency" configuration (d=8.5cm) one losses 2% for each Double Cluster missing, and 1% for each Triple Cluster missing. • In the "standard" configuration (d=23.5cm) one losses 1% for each Double or Triple Cluster missing.

  35. Outline • AGATA Geometry for experiments at GSI FRS (PRESPEC) • Performance in terms of efficiency and resolution • Angular dependence of the g-ray efficiency for several distances • Relativistic dependence of the efficiency on b • Performance vs. number of double and/or triple cluster available • Efficiency performance for pure E2 transitions • MC Simulation of a Fragmentation experiment • MC Simulation of the line-shape for DSAM analysis • First steps towards implementation of background in the simulations • Outlook • Conclusion

  36. AGATA S2' @ GSI: efficiency for pure E2 transitions (full align.) Dependence of the efficiency on the g-ray multipolarity (Isotropic vs. pure E2) E2 Isotropic

  37. AGATA S2' @ GSI: efficiency for pure E2 transitions (full align.) Dependence of the efficiency on the g-ray multipolarity (Isotropic vs. pure E2) E2 Isotropic

  38. AGATA S2' @ GSI: efficiency for pure E2 transitions (full align.) Dependence of the efficiency on the g-ray multipolarity (pure E2) E2 Isotropic Isotropic

  39. AGATA S2' @ GSI: efficiency for pure E2 transitions (full align.) Dependence of the efficiency on the g-ray multipolarity (pure E2) E2 Isotropic pure E2 Isotropic

  40. AGATA S2' @ GSI: efficiency for pure E2 transitions (full align.) Dependence of the efficiency on the g-ray multipolarity (pure E2) E2 ? Isotropic pure E2 Isotropic

  41. Outline • AGATA Geometry for experiments at GSI FRS (PRESPEC) • Performance in terms of efficiency and resolution • Angular dependence of the g-ray efficiency for several distances • Relativistic dependence of the efficiency on b • Performance vs. number of double and/or triple cluster available • Efficiency performance for pure E2 transitions • MC Simulation of a Fragmentation experiment • MC Simulation of the line-shape for DSAM analysis • First steps towards implementation of background in the simulations • Outlook • Conclusion

  42. MC Simulation of a reference fragmentation experiment Realistic MC Simulation of a fragmentation experiment • Event Reconstruction • Detectors resolution • Doppler-correction • Tracking • Event Builder • Detector AGATA response (list of hits) + Ancillaries • (by Enrico Farnea) • Primary Event Generator • fragmentation • (coulex) • (by Pieter Doornenbal)

  43. Fragmentation Experiment Benchmark: 54Ni -> 50Fe* 10+ 1581 keV 8+ 1627 keV 6+ 1308 keV 4+ 1087 keV 2+ 765 keV 0+ Realistic MC Simulation of a fragmentation experiment 50Fe 54Ni @ 150 MeV/u • Primary Event Generator • fragmentation • g-ray decay • (by Pieter Doornenbal) Be Target (700mg/cm2) 50Fe

  44. Fragmentation Experiment Benchmark: 54Ni -> 50Fe* Realistic MC Simulation of a fragmentation experiment 50Fe • Primary Event Generator • fragmentation • g-ray decay • (by Pieter Doornenbal) 54Ni @ 150 MeV/u Be Target (700mg/cm2) b before b after g-ray vertex spatial distribution

  45. Fragmentation Experiment Benchmark: 54Ni -> 50Fe* • Event Builder • Detector (AGATA) response (list of hits) • (by Enrico Farnea) Realistic MC Simulation of a fragmentation experiment Be Target (700mg/cm2) GAMMA 1 1000.0000 RECOIL 0.5000 0.0000 0.0000 0.0000 1.0000 0.0000 SOURCE 0 0 0.0000 0.0000 0.0000 $ -1 1401.723 -0.43045 0.48009 0.76434 0 29 73.617 -142.729 141.623 234.825 52 1.053 29 39.475 -143.302 150.765 245.890 52 1.129 29 148.895 -151.199 143.686 236.472 51 1.083 29 155.373 -151.207 143.675 236.479 51 1.083 29 251.516 -129.956 144.860 230.891 41 1.007 29 166.208 -129.833 144.792 230.981 41 1.008 29 163.364 -129.791 144.692 230.949 41 1.008 29 132.162 -129.764 144.711 230.911 41 1.008 29 86.873 -129.765 144.716 230.913 41 1.008 -1 1627.135 0.23197 -0.26644 0.93552 1 1 126.640 125.339 -75.549 240.008 34 1.154 1 334.250 120.598 -82.006 265.573 43 1.065 1 71.117 120.608 -81.984 265.633 43 1.065 1 160.091 120.600 -81.997 265.637 43 1.065 1 11.067 120.642 -81.972 265.678 43 1.065 1 45.200 120.643 -81.971 265.679 43 1.065 -1 1087.822 -0.71426 -0.56881 0.40778 2 -1 1257.962 -0.08354 0.77764 0.62313 3 24 129.869 -24.004 192.131 156.311 05 0.836 24 30.817 -34.318 197.026 157.088 15 0.874 . . . . .

  46. Fragmentation Experiment Benchmark: 54Ni -> 50Fe* • Event Reconstruction • Detectors resolution • Doppler-correction • Tracking 10+ 1581 keV 8+ 1627 keV 6+ 1308 keV 4+ 1087 keV 2+ 765 keV 0+ Realistic MC Simulation of a fragmentation experiment Raw Low Statistics Doppler Corr. Raw High Statistics Doppler Corr. 50Fe

  47. Outline • AGATA Geometry for experiments at GSI FRS (PRESPEC) • Performance in terms of efficiency and resolution • Angular dependence of the g-ray efficiency for several distances • Relativistic dependence of the efficiency on b • Performance vs. number of double and/or triple cluster available • Efficiency performance for pure E2 transitions • MC Simulation of a Fragmentation experiment • MC Simulation of the line-shape for DSAM analysis • First steps towards implementation of background in the simulations • Outlook • Conclusion

  48. Another example: line shape analysis on first 2+ of 74Ni 2+ 1024 keV 0+ 74Ni Realistic MC Simulation of a fragmentation experiment: DSAM Analysis 74Ni 76Zn @ 150 MeV/u t = ? Fe Target (500mg/cm2) t = 0.5 to 1.5 ps Zoom

  49. Outline • AGATA Geometry for experiments at GSI FRS (PRESPEC) • Performance in terms of efficiency and resolution • Angular dependence of the g-ray efficiency for several distances • Relativistic dependence of the efficiency on b • Performance vs. number of double and/or triple cluster available • Efficiency performance for pure E2 transitions • MC Simulation of a Fragmentation experiment • MC Simulation of the line-shape for DSAM analysis • First steps towards implementation of background in the simulations • Outlook • Conclusion

  50. Realistic MC Simulation: Background Degrader Target