170 likes | 322 Views
Coulomb excitation of the neutron-rich 67,69,71,73 Cu with Miniball and REX-ISOLDE Experiment IS435. Irina Stefanescu 1 , O. Ivanov 1 , J. Van de Walle 1 , N. Patronis 1 , D. Pauwels 1 , T. E. Cocolios 1 , N. Bree 1 , M. Huyse 1 , P. Van Duppen 1.
E N D
Coulomb excitation of the neutron-rich 67,69,71,73Cu with Miniball and REX-ISOLDE Experiment IS435 Irina Stefanescu1, O. Ivanov1, J. Van de Walle1, N. Patronis1, D. Pauwels1, T. E. Cocolios1, N. Bree1, M. Huyse1, P. Van Duppen1 G. Georgiev2, T. Kröll3, P. Maierbeck3, A. Blazhev4, N. Warr4, S. Franchoo5, J. Iwanicki6, P. Napiorkowski6, K. Wrzosek6, D. Balabanski7, K. Gladnishki7, G. Rainovski7, G. Lo Bianco8, N. Blasi8, A. Lagoyannis9, T. Konstantinopoulos9, A. Ekström10 1IKS, KU Leuven 2CSNSM Orsay, France 3TU München, Germany 4IKP Köln, Germany 5IPN Orsay, France 6Heavy Ion Laboratory, Warsaw University, Poland 7University of Sofia, Bulgaria 8Universita di Camerino, Italy 9National Research Center Demokritos, Greece 10Lund University, Sweden Funded by IAP Belgium, BMBF, EURONS
measured by Coulex with RIBs g9/2 “monopole migration” g9/2 40 p1/2 f5/2 p3/2 28 f7/2 protons neutrons Beyond 68Ni by Coulomb excitation with RIBs
g9/2 2 (7/2-) Eex (MeV) (7/2-) 1 (5/2-) (3/2-) 71Cu42 0 67,69,71,73Cu and the monopole migration (f7/2)-1 7/2- 7/2- 7/2- 7/2- p3/22+ (A-1Ni) 5/2- p1/2 1/2- (7/2-) f5/2 5/2- (7/2-) 1/2- (5/2-) 3/2- p3/2 3/2- (3/2-) 67Cu38 69Cu40 73Cu44 67,69Cu: B. Zeidman et al., PRC 18, 2122(1978). 71Cu: R. Grzywacz et al., PRL 81, 766 (1998). 69,71,73Cu: S. Franchoo et al., PRL 81, 3100(1998).
g9/2 2 (7/2-) Eex (MeV) (7/2-) 1 (5/2-) (3/2-) 71Cu42 0 67,69,71,73Cu and the monopole migration SF SF (f7/2)-1 7/2- 3.1 7/2- 0.45 0.9 7/2- 2.7 7/2- p3/22+ (A-1Ni) 5/2- p1/2 1.5 1/2- 0.26 (7/2-) f5/2 5/2- 0.3 (7/2-) 1/2- 0.46 (5/2-) 3/2- p3/2 1.9 3/2- 1.3 (3/2-) 67Cu38 69Cu40 73Cu44 67,69Cu: B. Zeidman et al., PRC 18, 2122(1978). 71Cu: R. Grzywacz et al., PRL 81, 766 (1998). 69,71,73Cu: S. Franchoo et al., PRL 81, 3100(1998).
Radioactive beams of 67,69,71,73Cu • UCx target – Ta line • ionized by RILIS • REX: ~2.95 MeV/u • beams contaminated with the Ga isobar • laser ON/OFF runs 67Cu/total~ 98 % 69Cu/total~ 94 % 71Cu/total~ 76 % 73Cu/total~ 19 %
Experimental results (1) 67Cu 7/2- 2340 (f7/2)-1 5/2- 7/2- 1670 p3/22+ (66Ni) 1/2- 7/2- 1/2- 1170 104Pd 5/2- 1115 67Cu38 DC for A=67 3/2- 1871 69Cu 7/2- p3/22+ (68Ni) (f7/2)-1 7/2- 1711 1/2- 5/2- 1213 5/2- 7/2- 104Pd 1/2- 1096 69Cu40 DC for A=69 3/2-
Experimental results (2) (1/2-) 71Cu 454 keV 7/2- (7/2-) 1190 p3/22+ (70Ni) (f7/2)-1 (7/2-) 981 104Pd 71Ga (5/2-) 534 DC for A=71 (1/2-) 454 71Cu42 71Cu (1/2-) (3/2-) 5/2- 120Sn DC for A=71
Experimental results (3) DC for A=73 (1/2-) 73Cu 5/2- Laser ON (7/2-) 1010 (f7/2)-1 73Ga 120Sn p3/22+ (72Ni) (7/2-) 961 7/2- (5/2-) 166 (1/2-) 135 73Cu44 Laser OFF (3/2-)
new Experimental results (preliminary) spectroscopic factors from B. Zeidman et al., PRC 18, 2122(1978).
new Experimental results (preliminary) spectroscopic factors from B. Zeidman et al., PRC 18, 2122(1978).
Conclusion and outlook • Summer 2006 Coulex of 67,69,71,73Cu; • three B(E2) values measured in each isotope; • ½- identified in 71,73Cu. • strong effects of the N=40 sub-shell closure on the structure of the odd-mass Cu isotopes; • highly collective 1/2- state and single-particle-like 5/2- level in 69,71,73Cu; • interpreting the implications of the present results requires some theoretical input. • Summer 2007 Coulex of 75Cu
measured by Coulex with RIBs g9/2 monopole interaction j> = l+1/2 g9/2 f5/2 j< = l’-1/2 40 28 f7/2 j> = l’+1/2 protons neutrons Beyond 68Ni by Coulomb excitation with RIBs
j> = l+1/2 g9/2 f5/2 j< = l’-1/2 f7/2 j> = l’+1/2 protons neutrons
Resonant laser ionization (RILIS) Radioactive beams of 67,69,71,73Cu @ISOLDE 1.4 GeV proton beam UCx target REX-ISOLDE XCu+XGa ~2.95 MeV/u 67Cu: 2% 67Ga 73Cu: 80% 73Ga Miniball
Experimental set-up for Coulex @REX-ISOLDE • 4 quadrants • 16 annular strips () • 24 sector strips () Miniball DSSD detector (16o-53o) ACu REX- ISOLDE E~2.95 MeV/u Beam dump detector PPAC 120Sn, 104Pd ~2 mg/cm2 Beam monitor v/c ~ 7% Doppler correction of the -rays on an event-by-event mode by using the segmentation of the particle and -detectors.