1 / 22

Version 8.0 SphygmoCor Cardiovascular Management Suite Software

Version 8.0 SphygmoCor Cardiovascular Management Suite Software. Introducing SphygmoCor Version 8.0 Cardiovascular Management Suite.

kemal
Download Presentation

Version 8.0 SphygmoCor Cardiovascular Management Suite Software

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Version 8.0 SphygmoCor Cardiovascular Management Suite Software

  2. Introducing SphygmoCor Version 8.0 Cardiovascular Management Suite • This slide-set highlights the new features of SphygmoCor Version 8.0 Cardiovascular Management Suite Software, with emphasis on the key enhancements that are included in this release. • This software release features significant improvements in the presentation of key parameters against normal reference ranges, including the central blood pressures that were recently shown in the STRONG heart study and CAFE substudy of the ASCOT trial to be of independent predictors of cardiovascular risk. • Importantly, all existing data for upgraded systems previously running Version 7.1 is automatically uploaded into Version 8.0. • Version 8.0 provides the platform for Heart Rate Variability as an add-on option which will become available in the near future (following 510k clearance in the USA and CE Mark in Europe). This add-on option is currently available in selected countries in the Asia-Pacific Region.

  3. SphygmoCor Version 8.0 Cardiovascular Management Suite: Overview • Greater emphasis on clinical presentation of central blood pressure and other key central cardiovascular parameters. • Improved confidentiality with Privacy Button and hiding of family names. • Patient Results now displayed over 3 screens to enhance the presentation of clinical information. • Clinical Screen shows numerical values of patient measurements and reference range, as well as a bar graph with data plotted against reference normals. • Detailed Screen, which still provides information relating to both the radial and central waveforms, along with quality control data. • Reference range screen added.

  4. SphygmoCor Version 8.0 Cardiovascular Management Suite: Overview (cont.) • Central systolic pressure and central pulse pressure is now available with respect to normal reference ranges, both numerically and graphically. • Both adjusted and unadjusted Augmentation Index (AIx) plotted against normal reference range for greater clarity of the effect of heart rate for this parameter. • An additional graph for sub-endocardial viability ratio (SEVR) showing patient measurement against reference range provided to complement the existing graph. • PWV carotid-femoral measurements plotted on graph against normal reference range

  5. Version 8.0 Cardiovascular Management Suite Enhanced Clinical Screen

  6. Clinical Screen Enhancements • Peripheral blood pressure measurements moved to the study panel and central blood pressure measurements clearly displayed together with other key central clinical parameters. • Central systolic pressure and central pulse pressure now available with respect to normal reference ranges, both numerically and graphically. • Both adjusted and unadjusted Augmentation Index (AIx) plotted against normal reference range for greater clarity of the effect of heart rate for this parameter. • SEVR now available with respect to normal reference range. • See next two slides for comparison between versions 7.1 and 8.0 screens.

  7. Version 7.1 Clinical Screen

  8. Version 8.0 Clinical Screen

  9. Version 8.0 Cardiovascular Management Suite Newly-introduced Reference Range Screen

  10. Newly-introduced Reference Range Screen • All graphs are displayed at the same time, with user choice for the primary graph to be displayed. • New graphs in Version 8.0 include Aortic Systolic Pressure and Aortic Pulse Pressure. • Both the unadjusted and heart rate-adjusted Augmentation Index values are plotted on the same graph against the normal reference range. • The SEVR is shown in two graphs, with the new graph plotting the patient measurement against reference range to complement the currently existing graph.

  11. Version 8.0 Reference Range Screen

  12. Version 8.0 Cardiovascular Management Suite Enhanced Trend Screen

  13. Trend Screen Enhancement • The Trend Screen is now the first screen displayed in the Analysis section of the software, showing immediately the movement of each parameter over time. • The option to view the Waveform Screen is still available. • Bar graphs on the Trend Screen are now color-coded. • These color codes relate to normal reference range (i.e., high, normal, low), enhancing the longitudinal assessment of the patient.

  14. Version 7.1 Trend Screen

  15. Version 8.0 Trend Screen

  16. Version 8.0 Cardiovascular Management Suite Enhanced Pulse Wave Velocity Report Screen

  17. Version 8.0 Pulse Wave Velocity Screen • PWV carotid-femoral measurements plotted on graph against normal reference range

  18. Version 8.0 Pulse Wave Velocity Screen

  19. Version 8.0 Cardiovascular Management Suite Updated Patient Reports

More Related