450 likes | 911 Views
Automatic Transfer System AT y S. Motorised Changeover Switch. Normal / Emergency Application Control Relay. N EW S F EATURES. 2 functions. ATyS 6. ATyS C30. ATyS 3. AT y S. A utomatic T ransfer S witch. IEC60947- 3 (AC22B) compliant. AT y S 3. AT y S 6.
E N D
Motorised Changeover Switch Normal / Emergency Application Control Relay NEWS FEATURES • 2 functions ATyS 6 ATyS C30 ATyS3
ATyS Automatic Transfer Switch IEC60947-3 (AC22B)compliant ATyS 3 ATyS 6 IEC60947-6-1 (AC31B)compliant Normal / Emergency Controler ATyS C30 ATyS 3s New product for SMVS range ATyS 3e New product for SMVE range ATyS
OPTIONS OPTIONS A COMPLETE NEW RANGE ATyS C 30 ATyS 3e ATyS 6s ATyS 6e ATyS 6m ATyS 3s MOTORISED CHANGEOVER DOUBLE POWER SUPPLY N/E CONTROL RELAY INTEGRATED N/E CONTROL RELAY METERING REMOTE INTERFACES ATYS D10 or D20 ACCESSORIES
ATyS 3s PRODUCT Position Auxiliary Contacts Changeover AUT / Manu selector Power supply and control terminals Handle Support Padlocking Handle
ATyS 3e & 6 PRODUCTS Power Supply and Control terminals Optional modules connection Changeover Switch Power supply and control module Motorised module Auxiliary contacts Handle Support AUT / Manu selector Padlocking Handle
125-630A • 800-1600A 5 FRAMES – 2 CUTOUTS • Frame 3 : 125 – 160A • Frame 4 : 250 – 400A • Frame 5 : 630A • Frame 6 : 800 – 1250A • Frame 7 : 1600A
POWER SUPPLY AND SENSING CIRCUITS 2 1 • Fuse protection or power supply and voltage sensing kit usage
POWER SUPPLY AND SENSING CIRCUITS • Power supply and voltage sensing kit To complete the ATyS System concept ! • Routing of the conductors is controlled – no specific protection required • Adapted to any configuration (kit configuration required)
PANEL INTEGRATION • Back Panel • Flush • PLUG & PLAY Integration • The N / E function is operational as soon as the power cables are connected !
OPTIONS OPTIONS A COMPLETE NEW RANGE ATyS C 30 ATyS 3e ATyS 6s ATyS 6e ATyS 6m ATyS 3s MOTORISED CHANGEOVER DOUBLE POWER SUPPLY N/E CONTROL RELAY INTEGRATED N/E CONTROL RELAY METERING REMOTE INTERFACES ATYS D 10 OR D20 ACCESSORIES
A MOTORISED CHANGEOVER • Emergency manual operation • Padlocking in 0 position (position I & II as option) • AUT / Manu selector (key on versions e & m) • Electrical command (not on version 6s) • Position Auxiliary Contacts
OPTIONS OPTIONS A COMPLETE NEW RANGE ATyS C 30 ATyS 3e ATyS 6s ATyS 6e ATyS 6m ATyS 3s MOTORISED CHANGEOVER DOUBLE POWER SUPPLY N/E CONTROL RELAY INTEGRATED N/E CONTROL RELAY METERING REMOTE INTERFACES ATYS D 10 OR D20 ACCESSORIES
DOUBLE POWER SUPPLY • Automatic power supply taken from sources : 230Vac (+/-20%) 1 2 Source 1 available Source 2 available Sources 1 & 2 are available 4. No source available
OPTIONS OPTIONS A COMPLETE NEW RANGE ATyS C 30 ATyS 3e ATyS 6s ATyS 6e ATyS 6m ATyS 3s MOTORISED CHANGEOVER DOUBLE POWER SUPPLY N/E CONTROL RELAY INTEGRATED N/E CONTROL RELAY METERING REMOTE INTERFACES ATYS D 10 OR D20 ACCESSORIES
A CONTROL RELAY • For any permutation requiring dead band • For any type of network
A CONTROL RELAY Loss of source I • Complete Automatic control sequences Position I Position II 0MF Position 0 Loss of network I DDT MFT Start Genset Emergency source available
A CONTROL RELAY Stop G enset after Cool down Source I Return Position II Position I CDT Source I return MRT 0MR Source I stable Position 0
A CONTROL RELAY • 3 operational « Modes » available : • Visualisation • Programming • Operation
A CONTROL RELAY • Visualisation : • Parameters (Voltages, Frequencies, Currents, Power …) • Control Timers • Number of operations U f
A CONTROL RELAY • Programming : Allows parameters programming: • Network • Changeover configuration • Changeover Control • Operations (thresholds and timers) • Optional modules • Password access
A CONTROL RELAY • Operation : • Tests and electrical control : • Test on load • Test off load • Position control (electrical control) • Password Access • Test on load and ElectricalControl areaccessible from external contacts
OPTIONS OPTIONS A COMPLETE NEW RANGE ATyS C 30 ATyS 3e ATyS 6s ATyS 6e ATyS 6m ATyS 3s MOTORISED CHANGEOVER DOUBLE POWER SUPPLY N/E CONTROL RELAY INTEGRATED N/E CONTROL RELAY METERING REMOTE INTERFACES ATYS D 10 OR D20 ACCESSORIES
AN INDEPENDANT CONTROL RELAY • ATyS C30 « DIN rail mounting close to power circuit » • ATyS 3 • SMVS ou SMVE • Contactors • Breakers
AN INDEPENDANT CONTROL RELAY • ATyS C30 • Main features : • Automatic cycles similar to ATyS 6 • 3U control Network 1 & 1U control on network 2 • Position control ( I, 0, II ) using Contactor or Impulse logic • Automatic Power Supply taken from sensing inputs • Start genset relay • 2 configurable inputs • 2 configurable outputs
Changeover control 0u1 0u2 In1 In2 Pos 1 Pos 2 CA0 CA1 CA2 Strart GE R’ T R N T’ S Sensing 3U network 1 + power Sensing 1U network 2 + power AN INDEPENDANT CONTROL RELAY • ATyS C30 Ou1, Ou2 : configurables outputs In1, In2 : configurable inputs
OPTIONS OPTIONS A COMPLETE NEW RANGE ATyS C 30 ATyS 3e ATyS 6s ATyS 6e ATyS 6m ATyS 3s MOTORISED CHANGEOVER DOUBLE POWER SUPPLY N/E CONTROL RELAY INTEGRATED N/E CONTROL RELAY METERING REMOTE INTERFACES ATYS D 10 OR D20 ACCESSORIES
OPTIONS • Optional modules • 2 slots on ATyS 3e & 4 on ATyS 6e et 6m • N°1 : communication • N°2 : 2I/2O for ATyS 3e, 6e / 6m • Inputs: 10-30Vdc power supply available on ATyS 6 • Outputs: NO dry contacts Features: Priority change, Load shedding, S1 or S2 available, External fault, Remote Manual Retransfer
OPTIONS OPTIONS A COMPLETE NEW RANGE ATyS C 30 ATyS 3e ATyS 6s ATyS 6e ATyS 6m ATyS 3s MOTORISED CHANGEOVER DOUBLE POWER SUPPLY N/E CONTROL RELAY INTEGRATED N/E CONTROL RELAY METERING REMOTE INTERFACES ATYS D 10 OR D20 ACCESSORIES
A COMPLETE RANGE • Metering 6m 6e 6s q q q q q q q q q q • U Network 1 et 2 • F Network 1 et 2 • I1, I2, I3 & IN calculated • Pt, P1, P2, P3, signed • Qt, Q1, Q2, Q3, signed • St, S1, S2, S3 signed • FPt, FP1, FP2, FP2, inductive or capacitive
OPTIONS OPTIONS A COMPLETE NEW RANGE ATyS C 30 ATyS 3e ATyS 6s ATyS 6e ATyS 6m ATyS 3s MOTORISED CHANGEOVER DOUBLE POWER SUPPLY N/E CONTROL RELAY INTEGRATED N/E CONTROL RELAY METERING REMOTE INTERFACES ATYS D 10 OR D20 ACCESSORIES
REMOTE INTERFACES • ATyS D10 and D20: • Remote Command, configuration & signalisation • Compatible with ATyS 6e, 6m & C30 • RJ45Connection • Easy mounting : 2 holes diameter 22,5mm
REMOTE INTERFACES • ATyS D20 • Optimised backlited Metering (Sources 1 et 2 simultaneously, priority source display…) • Direct Access to test séquences (on load, off load,...) & control
A COMPLETE RANGE or + or + or Same front design !
OPTIONS OPTIONS A COMPLETE NEW RANGE ATyS C 30 ATyS 3e ATyS 6s ATyS 6e ATyS 6m ATyS 3s MOTORISED CHANGEOVER DOUBLE POWER SUPPLY N/E CONTROL RELAY INTEGRATED N/E CONTROL RELAY METERING REMOTE INTERFACES ATYS D 10 OR D20 ACCESSORIES
ACCESSORIES • Terminal shroud : upstream, downstream, front, back mounting (be careful in case of bridging bars or sensing kit mounting) • Terminal shrouds • Upstream and dowstream mounting • protection against direct contacts • Voltage Transformer for 400V without neutral applications
ACCESSORIES • Ronis EL11AP key interlocking system • Mounting spacers