1 / 32

Recent status of the XMASS project

Recent status of the XMASS project. Physics goals at XMASS Overview of XMASS Current status of R&D Summary. Yasuo Takeuchi (Kamioka Observatory, ICRR, Univ. of Tokyo) for XMASS Collaboration.

kesia
Download Presentation

Recent status of the XMASS project

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recent status of the XMASS project • Physics goals at XMASS • Overview of XMASS • Current status of R&D • Summary Yasuo Takeuchi (Kamioka Observatory, ICRR, Univ. of Tokyo) for XMASS Collaboration XMASS = a multi purpose detector to search rare phenomena under an ultra low background environment by using ultra pure liquid xenon Y.Takeuchi @ICHEP04 in Beijing

  2. Measure pp n via n + e n + e pp +-1% http://www.sns.ias.edu/~jnb/ Physics goals at XMASS XMASS FV 50 ton year (90%CL) G. Gratta @Neutrino2004 • Xenon MASSive Detector for Solar Neutrinos (pp/7Be) • Xenon Detector for Weakly Interacting MASSive Particles (Dark Matter Search) • Xenon Neutrino MASS Detector (Double Beta Decay) 2nbb life time should be measured Isotope separation would be needed Y.Takeuchi @ICHEP04 in Beijing

  3. Expected signal XMASS FV 0.5ton year Eth=5keV, 3s discovery Physics goals at XMASS Spin Independent Direct search via nuclear elastic scattering Eth = 20keV ~3 events/day/ton Eth = 5keV ~200 events/day/ton • Xenon MASSive Detector for Solar Neutrinos (pp/7Be) • Xenon Detector for Weakly Interacting MASSive Particles (Dark Matter Search) • Xenon Neutrino MASS Detector (Double Beta Decay) Y.Takeuchi @ICHEP04 in Beijing

  4. 2nbb t1/2 theory= 8 x 1021 y Physics goals at XMASS • Search for 0nbb (2nbb) decay of 136Xe (na 8.87%) • High purity and enriched Xe can be used. • Energy region is different from solar n / DM. • PMTs should not be placed near the detector. 136Xe 136Ba + e- + e- Q-Value: 2.48 MeV Need another design of the detector! (low priority, at moment…) • Xenon MASSive Detector for Solar Neutrinos (pp/7Be) • Xenon Detector for Weakly Interacting MASSive Particles (Dark Matter Search) • Xenon Neutrino MASS Detector (Double Beta Decay) Y.Takeuchi @ICHEP04 in Beijing

  5. Overview of XMASS Strategy Key ideas (self shielding, distillation)

  6. Strategy of the XMASS project NOW ~1m ~2.5m ~30cm ~1 ton detector (FV 100kg) Dark matter search ~20 ton detector (FV 10ton) Solar neutrinos Dark matter search Prototype detector (FV 3kg) R&D Confirmation of feasibilities of the ~1 ton detector Analysis techniques Self shielding performance Low background properties Purification techniques Dedicated detector for Double beta decay search Y.Takeuchi @ICHEP04 in Beijing

  7. Self shielding 30cm 105 reduction for < ~500keV Liquid Xe Volume for shielding Fiducial volume PMTs Reconstruct the vertex and energy based on PMTs information (light pattern) • Quite effective for the events below ~500 keV (pp n & DM) • Not effective for double beta decay experiment Y.Takeuchi @ICHEP04 in Beijing

  8. Distillation to remove Kr • Very effective to eliminate internal impurities (85Kr, etc.) • We have processed 100kg Xe in March ‘04 Lower temp. Off gas Xe: 330±100 ppb Kr (measured) Raw Xe: ~3 ppb Kr ~1% ~3m Operation: 2 atm Processing speed: 0.6 kg / hour Design factor: 1/1000 Kr / 1 pass 13 stage of 2cmf Higher temp. Purified Xe: < 5 ppt Kr (measured) ~99% Y.Takeuchi @ICHEP04 in Beijing

  9. Current status of R&D Prototype detector Results from test runs Self shielding Internal background External background

  10. 1.0m 1.9m XMASS prototype detector • 30 litter liquid Xenon (~100kg) • Oxygen free copper: (31cm)3 • 54 of low-BG 2-inch PMT • Photo coverage~16% • MgF2 window • 0.6 p.e. / keV n Polyethylene (15cm) Boric acid (5cm) g Lead (15cm) EVOH sheets (30mm) OFC (5cm) Rn Rn free air(~3mBq/m3) Y.Takeuchi @ICHEP04 in Beijing

  11. Test runs with the prototype detector • December 2003 run • First test run • ~6 days (~2day normal runs for BG estimation) • Test analysis tools • Confirmation of the self shielding performance • Measurements of the internal and external BGs • August 2004 run • August 3 ~ 11, 2004, 9days (~6day normal runs) • Used purified xenon (by distillation) • Longer baking time of the system • New electronics (TDC, etc.) • Re-measurements of the internal and external BGs NEW Photon yield x ~1.7 Y.Takeuchi @ICHEP04 in Beijing

  12. Self shielding performance g Reconstructed vertex position of collimated source runs Z= -15 Z= +15 137Cs (662keV) 60Co (1173 & 1333keV) Data MC Data MC Dec.03 run Remove events (PMT saturation) • MC reproduces data very well • We have demonstrated the self-shield actually works Y.Takeuchi @ICHEP04 in Beijing

  13. Aug.04 run Preliminary 238U Internal BG source: 222Rn 222Rn DT < 1ms • 2 separate runs to check 222Rn decay (t1/2=3.8day) • 4th Aug. 0.8day 238U=(72+-11)x10-14 g/g • 10th Aug. 1.0day 238U=(33+-7)x10-14 g/g • Consistent with expected 222Rn decay ((30+-5)x10-14 ) 214Bi214Po210Pb (1.8days) b (Emax=3.3MeV) a (7.7MeV) 3.5MeV t1/2 =164msec 67ev DT: t1/2 = 141+-51msec DL Y.Takeuchi @ICHEP04 in Beijing

  14. Preliminary Internal background sources • Current results • 238U: = (33+-7)x10-14g/g • 232Th: < 63x10-14g/g • Kr: < 5ppt Goal (~1ton) 1x10-14 g/g NEW Factor ~30, but may decay out further 2x10-14 g/g Factor <~30 (under further study) 1 ppt NEW Almost achieved by the distillation process Y.Takeuchi @ICHEP04 in Beijing

  15. External background sources • Background level was estimated from known sources MC estimation for full volume • g rays from outside shield • PMTs origin • 238U series • 40K • 232Th series • 210Pb in the lead shield [count/keV/day/kg] (=dru) Energy (keV) Y.Takeuchi @ICHEP04 in Beijing

  16. Aug.04 run Preliminary Measured background level Geometrical effect only for prototype detector • Self shielding works • Good agreement with expectation (< factor 2) Simulation Measurements All volume All volume 20cm FV 20cm FV 10cm FV 10cm FV Y.Takeuchi @ICHEP04 in Beijing

  17. Aug.04 run Preliminary Alpha vs Gamma separation FADC data Charge Alpha-like Gamma-like Pulse width (ns) Alpha-gamma separation by using FADC wave form would be possible (under further investigation) Y.Takeuchi @ICHEP04 in Beijing

  18. Summary • XMASS is aiming to search rare phenomena under an ultra low background environment by using ultra pure liquid xenon. • 2nd test run with the prototype detector was just finished. • The data were taken using distilled xenon with low level krypton (Kr/Xe < 5ppt). • Some part of remaining 222Rn in liquid xenon looks contaminated in outside of the chamber. • The background level is consistent with expectation within factor about 2. • The next step (~1ton scale) would be feasible, and a dark matter search around 10-44 cm2level would be possible. Y.Takeuchi @ICHEP04 in Beijing

  19. Supplement Y.Takeuchi @ICHEP04 in Beijing

  20. Why liquid xenon scintillator • High photon yield • Low threshold, good energy resolution, … • Can be directory read by PMT • Large atomic number • Radiation length ~2.4cm • Self shielding against external backgrounds • Compact (R=1.22m for 23 tons) • Easy to liquefy • Liquid N2 can be used • Various purification method • Distillation, circulation during experiment, … • Effective reduction against internal backgrounds • No long life radioactive isotopes • 136Xe is a bb decay candidate Y.Takeuchi @ICHEP04 in Beijing

  21. Development of the low BG PMT Q.E. ~ 30% @ 175nm; Collection eff. ~ 90% Quartz window&Metal tube (Low BG) Selection of the parts (measured by HPGe)  Low BG PMT base ~1/10 of the usual ones U 1.5±0.3x10-3 Bq Th 3.2±4.6x10-4 Bq 40K 1.7±2.9x10-3 Bq Aiming for another order of magnitudes improvement Hexagonal PMT to accomplish 70-80% PMT coverage Y.Takeuchi @ICHEP04 in Beijing

  22. Dec.03 run Energy/vertex reconstruction Real data Using photoelectron map made by MC (not timing, but charge information) Vertex: MC hitmap Energy: Hitmap scale Reconstructed here L: likelihood m : F(x,y,z,i)/S F(x,y,z,j) x(total p.e.) j . n: observed number of p.e. F(x,y,z,i): hitmap made by MC VUV photon characteristics: Lemit=42ph/keV tabs=34cm tscat=30cm 137Cs 662keV Gamma ray ( from a collimator) Y.Takeuchi @ICHEP04 in Beijing

  23. + + + C B A Collimated gamma rays for three different positions Event reconstruction Real data Hole C Hole B Hole A MC 137Cs Reconstruction works well Dec.03 run Y.Takeuchi @ICHEP04 in Beijing

  24. Aug.04 run Preliminary Stability of the energy scale 60Co calibration data Peak position from simple gaussian fit +-0.5% • No degrading of the energy scale • Stable within +-0.5% Y.Takeuchi @ICHEP04 in Beijing

  25. Aug.04 run Preliminary Observed light yield • Observed number of photons for source runs are increased by factor ~1.7 • xenon purification • longer baking time • removal of unnecessary material in the chamber Y.Takeuchi @ICHEP04 in Beijing

  26. Dec.03 run 85Kr: 687keV beta analysis The event rate around 200~400 keV in the Normal runs could be explained by 2~3ppb of Kr. Y.Takeuchi @ICHEP04 in Beijing

  27. Aug.04 run Preliminary Measured background level • Excess in 200-400keV in Dec. 2003 run may be due to 85Kr Simulation Dec. 2003 run Aug. 2004 run All volume 20cm FV 10cm FV Y.Takeuchi @ICHEP04 in Beijing

  28. Dec.03 run 232Th series • a-tagged beta events of 212Bi and 212Po • High- and Middle-gain normal runs: 1.66day • 20cm fiducial volume cut (to reject external events) • 1st peak: < 2000p.e.(efficiency ~100%) • DT=160~6000nsec in Flash ADC (efficiency = 69%) • 2nd peak: 500 ~ 4500p.e.(efficiency ~100%) 212Bi212Po208Pb b (Emax=2.3MeV) a (8.8MeV) (BR=64%) t1/2 =299nsec 1 event remained Y.Takeuchi @ICHEP04 in Beijing

  29. Dec.03 run Typical FADC data & peak search • 54 PMT analog sum 1 FADC • Range: -8 ~ +8msec • 80~240nsec window • Threshold: 70 count (4~12p.e.) • Most of peaks = after pulses from PMT FADC count Pedestal (80nsec) Peak position nsec Trigger timing Y.Takeuchi @ICHEP04 in Beijing

  30. Dec.03 run 232Th series: Bi-Po analysis (FADC) 1st peak 2nd peak (DT~700nsec) (OK) (very high energy?) FADC count Keep this event conservatively, for now nsec Trigger timing 1 candidate event 232Th < 63x10-14 g(232Th)/g(Xe) (90%CL) (only stat. error) Y.Takeuchi @ICHEP04 in Beijing

  31. An idea of dedicated detector for0nbb Put room temperature LXe into a thick, acrylic pressure vessel (~50atm). (symbolically) Test vessel held 80 atm water Wavelength shifter inside the vessel. We already have 10kg enriched 136Xe. Y.Takeuchi @ICHEP04 in Beijing

  32. Assume acrylic material U,Th~10-12g/g, no other BG. Cylindrical geom. (4cm dia. LXe, 10cm dia. Vessel) 10kg 136Xe 42000photon/MeV but 50% scintillation yield, 90% eff. shifter, 80% water transparency, 20% PMT coverage, 25% QE  57keVrms @ Qbb=2.48MeV Expected sensitivity U+Th normalized for 10kg, 1yr 1yr, 10kg measurement 1.5 x 1025 yr  <mn>=0.2~0.3eV If U/Th ~ 10-16 g/g + larger mass  <mn>~0.02-0.03eV 2nbb will not be BG thanks to high resolution Y.Takeuchi @ICHEP04 in Beijing