An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SPILLWAY DESIGN

  2. OGEE SPILLWAY Consider a concrete ogee spillway with vertical upstream face. The height of the spillway crest is kept at RL 204.0 m. The average river bed level at the site is 100.0 m. The spillway length consists of 6 spans having a clear width of 10 m each. Thickness of each pier is 2.5 m with 90o cut water nose piers and rounded abutments provided. Determine the discharges for operating heads of 0.75He, 0.50He and 0.25He, where the design head for discharge of 8000 m3/s is 16.4m. Comment on the results.

  3. Design an ogee spillway with the following data: (i) Height of spillway crest above river bed = 100 m (ii) Design discharge = 12,000 cumecs (iii) Number of spans = 6 (iv) Clear distance between piers = 15 m (v) Thickness of pier = 3 m Slope of d/s face of the overflow section = 0.8:1 Assume any other data if required.