IHE LCSD Profile – Laboratory Code Set Distribution

IHE LCSD Profile – Laboratory Code Set Distribution. Based on HL7 version 2.x, Chapter 8. Jean-Christophe Cauvin, France Ren é Spronk, Ringholm GmbH IHE Laboratory Planning and Technical Committee. Laboratory IHE Integration Profiles. Laboratory Scheduled Workflow (LSWF) Completed in 2003.

khuong
Download Presentation

IHE LCSD Profile – Laboratory Code Set Distribution

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IHE LCSD Profile –Laboratory Code Set Distribution Based on HL7 version 2.x, Chapter 8 Jean-Christophe Cauvin, France René Spronk, Ringholm GmbH • IHE Laboratory Planning and Technical Committee IHE Educational Meeting

  2. Laboratory IHE Integration Profiles Laboratory Scheduled Workflow (LSWF) Completed in 2003 Laboratory Point Of Care Testing (LPOCT) In Process –TI Nov 2004 Tests performed by a laboratory for an identified inpatient or outpatient Tests performed on point of care or patient’s bedside Laboratory Information Reconciliation (LIR) In Process Laboratory Device Automation (LDA)In Process –TI Nov 2004 Tests performed on an unidentified or misidentified patient Pre-analytic process, analysis and post-analytical treatment Laboratory Code Set Distribution (LCSD) Sharing the batteries and tests code sets throughout the enterprise IHE Educational Meeting

  3. LSWF: Workflow Clinical validation Technical validation Selected standard: HL7 version 2.5 IHE Educational Meeting

  4. The Laboratory Technical Framework • Laboratory Code Set Distribution IHE Educational Meeting

  5. Laboratory Code Set Distribution • The goal of this profile is to simplify the configuration of the systems involved in the Laboratory Scheduled Workflow. • The Laboratory Code Set Distribution Profile offers the means to share the same set of test/observation codes between different actors. • Other information can be also exchanged like presentation of results, laboratory codes (in which lab a test is performed), units … IHE Educational Meeting

  6. Laboratory Code Set Distribution Actors/Transaction Order Filler Enterprise Common Repository … Laboratory Code Set Master LAB-xx: Laboratory Code Set Management Laboratory Code Set Consumer Order Placer Order Result Tracker Automation Manager Order Filler … IHE Educational Meeting

  7. Laboratory Code Set Distribution Use Case 1 Laboratory Code Set Master Laboratory Code Set Consumer Creates observation/test/battery codes Laboratory Code Set Management (REP) Replaces Observation/Test/Battery Code Sets All Observation, Test and Battery code sets of the Consumer are replaced by the code sets sent by the Master. This Use Case is used both for initialization as well as periodic (weekly, monthly) update. IHE Educational Meeting

  8. Laboratory Code Set Distribution Use Case 2 (out of scope for this year) Laboratory Code Set Master Laboratory Code Set Consumer Updates observation/test/battery codes Laboratory Code Set Management (UPD) Updates Observation/Test/Battery Code Sets Observation, Test and Battery codes of the Consumer are updated by codes sent by the Master. Updates are at the record level : add record(s), delete record(s), update record(s). IHE Educational Meeting

  9. Laboratory Code Set Distribution Use Case 3 (out of scope for this year) Laboratory Code Set Master Laboratory Code Set Consumer Unknown / Expired observation/test/battery codes Query for Laboratory Code Set Laboratory Code Set Management Query for Observation/Test/Battery Code Sets The Laboratory Code Set consumer either periodically queries for the entire codeset, or it queries for the details of specific Observation, Test and Battery codes. The query responses are used to update the code set are at the record level : add record(s), delete record(s), update record(s). IHE Educational Meeting

  10. Laboratory Code Set Distribution Standard Interactions based on HL7 V2.5, Master Files (chapter 8). • Advantages of using HL7 V2.5: • HL7 is already implemented on laboratory systems; no need to implement a new protocol • Master Files are already adopted by some vendors. • Messages are rich enough to transport other information than just observation/test/battery codes : • presentation of the results • laboratory codes • units of measure IHE Educational Meeting

  11. HL7 Master Files Master files are a set of common reference files used by one or more application systems. Some common examples of master files in the healthcare environment include: • staff and health practitioner master file • location (census and clinic) master file • lab test definition file • exam code (lab, radiology) definition file IHE Educational Meeting

  12. Generic MFN – Abstract Message MSH MFI Master File Identification { MFE Master File Entry [ <other resource related segments, e.g. LOC > ] } 1..n MFI MFE 0..n LOC IHE Educational Meeting

  13. Generic MFN – Location Example MSH|^~\&|MyHIS||PhysioApp||200211221003||MFN^M05|31|P|2.4||AL|NE MFI|LOC|EH_Locations|UPD|||ER MFE|MDL|M226||Aqua1^^^Eastern Hospital^^^Physio^B^ Aqua therapy room 1|PL LOC|Aqua1^^^Eastern Hospital^^^Physio^B^Aqua therapy room 1||L MFE|MUP|M227||Aqua2^^^Eastern Hospital^^^Physio^B^ Aqua therapy room 2|PL LOC|Aqua2^^^Eastern Hospital^^^Physio^B^Aqua therapy room 2| Aqua therapy room 2|L|Eastern Hospital| LDP| Aqua2^^^Eastern Hospital^^^Physio^B^Aqua therapy room 2|PHY^ Physiotherapy||REH~PRE|D~O| IHE Educational Meeting

  14. Generic MFN Event Codes MFI – File Level Event Codes • REP: Replace current version of this master file with the version contained in this message. • UPD: Change file records as defined in the record-level event codes for each record that follows. (out of scope for this year) MFE – Record Level Event Codes • MAD: Add record to master file. • MDL: Delete record from master file. • MUP: Update record for master file. • MDC: Deactivate: discontinue using record in master file, but do not delete from database. • MAC: Reactivate deactivated record. IHE Educational Meeting

  15. Generic MFK – Acknowledgment MSH MSA Message Acknowledgement [ERR] MFI Master File Identification { [MFA] Master File Acknowledgement } Only in case of errors in related MFE/LOC 0..n MFI MFA 1..n MFI MFE 0..n LOC IHE Educational Meeting

  16. Generic MFK Ack, Location Example MSH|^~\&|FysioApp||MyZIS||200211221004||MFK^M05|31|P|2.4||AL|NE MFI|LOC|EH_Locations|UPD|||NE MFA|MDL|M226||U^Location not present| Aqua1^^^Eastern Hospital^^^Physio^B^Aqua therapy room 1|PL (NOTE: successful changes are NOT acknowledged) MFA|MUP|M227||S|Aqua2^^^Eastern Hospital^^^Physio^B^Aqua therapy room 2|PL IHE Educational Meeting

  17. Laboratory Code Set Distribution LAB-XXX Message Structures MFN^M08 – Master File Notification – Test/Observation (Numeric) MSH Message Header [1..1] chap. 2 MFI Master File Identification [1..1] chap. 8 { [1..*] MFE Master File Entry [1..1] chap. 8 OM1 General Segment [1..1] chap. 8 [OM2] Numeric Observation Segment [0..1] chap. 8 } MFN^M09 – Master File Notification – Test/Observation (Categorical) MFN^M10 – Master File Notification – Batteries MFN^M11 – Master File Notification – Test/Calculated Observation [OM3] Categorical Test/Obs. Segment [0..1] chap. 8 [OM5] Observation Batteries [0..1] chap. 8 [OM6 Obs. calculated from other Obs. [0..1] chap. 8 OM2] Numeric Observation Segment [0..1] chap. 8 IHE Educational Meeting

  18. Laboratory Code Set Distribution OM1 – General Segment OM1-2 Producer’s Service/Test/Observation ID OM1-4 Specimen required OM1-5 Producer ID OM1-18 Nature of Service/Test/Observation: P battery, A atomic, S super-set of batteries, C single observation calculated OM1-19 Report sub-header OM1-20 Report display order OM2 – Numeric Observation Segment OM2-2 Units of Measure OM2-3 Range of Decimal Precision IHE Educational Meeting

  19. Laboratory Code Set Distribution OM3 – Categorical Service/Test/Observation Segment OM3-2 Preferred Coding System OM3-3 Valid Coded answers OM5 –Observation Batteries Segment OM5-2 Tests/observations included within Battery OM6 –Observation that are Calculated OM6-2 Derivation Rule IHE Educational Meeting

  20. Atomic Tests, Numeric Results MSH|^~\&|OF|LabSystem|OP||20050205094510||MFN^M08|2106|2.5|||NLD|8859/1|NL| MFI|OMA|OF_OMA_NL_20050205|REP|||ER| MFE|MAD|1846||1846^CREABL/Creatinine^L|CE| OM1|1|1846^CREABL/Creatinine^L|NM|Y|K231^Klinisch Chemisch Laboratorium^?|||Creatinine||||||||||A| OM2|1|umol/l|6.0|| OM4|1||stolbuis rode dop4||ml|^volbloed| MFE|MAD|1848||1848^CREAUV/Creatinine^L|CE| OM1|2|1848^CREAUV/Creatinine^L|NM|Y|K231^Klinisch Chemisch Laboratorium^?|||Creatinine||||||||||A| OM2|2|mmol/l|6.0|| OM4|2||24-uurs bokaal|||^urine verzamel| IHE Educational Meeting

  21. Test with derived result MSH|^~\&|OF|LabSystem|OP||20050205094520||MFN^M11|2107|2.5|||NLD|8859/1|NL| MFI|OMD|OF_OMD_NL_20050205|REP|||ER| MFE|MAD|1849||1849^CLEA/Creatinine clearance^L|CE OM1|1|1849^CLEA/Creatinine clearance^L|NM|Y|K231^Klinisch Chemisch Laboratorium^?|||Creatinine clearance||||||||||C| OM6|1|(CREAUV * HOEV) / (CREASE * 1440) OM2|1|ml/min|4.0|| IHE Educational Meeting

  22. Thank you for your attention… IHE Educational Meeting