JTC1 – SG-EEDC CENELEC TC215 WG3 (EN 50600 Series) Prepared by: M Gilmore Country: UK
CENELEC TC215 WG3 (EN 50600 series) • Name of organisation and associated bodies • CENELEC Technical Committee TC215 • “Electrotechnical Aspects of Telecommunication Equipment” • WG3 • “Facilities and infrastructures” • Description of what this organisation is addressing • First project: EN 50600 • Addressing the design of data centre facilities and infrastructures based on the following critieria • Availability • Physical security • Energy efficiency enablement • Providing the infrastructure necessary to measure, report and control the energy efficiency of a data centre addressing: • Building construction • Power distribution • Environmental control • Telecommunications cabling infrastructure • Security • Management and operational information • Who are the consumers • Designers and operators of data centres?
CENELEC TC215 WG3 (EN 50600 series) • Taxonomy, terms, definitions and metrics used and introduced. • Data centres adopt the widest possible definition • No restriction on size • No restriction on purpose/business model • No metrics used – the purpose of the EN 50600 series is to provide an infrastructure that enables the measurement and control of energy consumption and related parameters within a data centre, not how the data should be used (this matches the proposals being submitted by CENELEC BT WG 132-3) • Standards (certification) being proposed, developed or suggested. Current Standards • Planned delivery 2011 • Standards structure shown of the next slide
EN 50600-1 General concepts EN 50600-2-1 Building construction EN 50600-2-2 Power distribution EN 50600-2-3 Environmental control Annex A Risk assessment Annex B General design principles EN 50600-2-4 Telecomm’s cabling infrastructure Annex C Measurement methodologies, test procedures and report formats EN 50600-2-5 Security systems EN 50600-2-6 Management and operational information DATA CENTRE CLASSIFICATION • availability • security • energy efficiency enablement CENELEC TC215 WG3 (EN 50600 series)
CENELEC TC215 WG3 (EN 50600 series) • How does this relate to the scope of EEDC • The objective of EN 50600 series documents is to ensure that future data centres have the capacity to measure, control and monitor energy usage.
CENELEC TC215 WG3 (EN 50600 series) • Source material, references. • First drafts of EN 50600 series will be circulated Q4, 2010
Tick areas relevant to EEDC scope (excel doc separate)If required add new column for scope topic