KX-TD500 Technical Review

KX-TD500 Technical Review. Table of Contents. Introduction 1-7 KX-TD500 Basic and Expansion Shelf 8-16 TD500 Cards 17 CPU Card KX-TD50101 18-21 TSW Card KX-TD50102 22-26 New KX-TD500 Cards 27-33 Other Cards Supported 34-53 System Construction 54-58

krysta
Download Presentation

KX-TD500 Technical Review

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. KX-TD500 Technical Review

  2. Table of Contents Introduction 1-7 KX-TD500 Basic and Expansion Shelf 8-16 TD500 Cards 17 CPU Card KX-TD50101 18-21 TSW Card KX-TD50102 22-26 New KX-TD500 Cards 27-33 Other Cards Supported 34-53 System Construction 54-58 System Configuration 59-62 System Startup 63-65 Hardware Addressing 66- Maintenance Console Software 80-90

  3. Table of Contents Activity Three 91 Activity Four 92-98 Activity Five 99 Activity Six 100 Activity Seven 101-102 T1 103-122 Activity Eight 123-128 Activity Nine 129

  4. KX-TD500

  5. KX-TD500Digital Super Hybrid • This TD-based system will offer a smooth upgrade path for 2-cabinet TD1232 users as well as a starter system for the medium-sized businesses or high-end residential users

  6. KX-TD500Digital Super Hybrid • The system will provide the TD dealers with a larger system size, but offer a similar programming and user interface as currently offered by the TD308/816/1232. • The major differences between the existing TD line of systems and the KX-TD500 includes a new Windows-based programming tool, and the universal slot design.

  7. KX-TD500 System Outline • The KX-TD500 consists of a basic shelf and up to two expansion shelves. • The systems features a universal slot design enabling station, CO, and other function cards to be installed into free slots in the cabinets.

  8. Basic ShelfKX-TD500 • The Basic Shelf is the initial building-block of the KX-TD500 system allowing a single-cabinet system to be configured with up to a maximum of 192 ports. • The Basic Shelf then provides the foundation on which the system can be expanded by use of expansion shelves to configure a system up a maximum of 512 ports.

  9. Basic ShelfKX-TD500 • The Basic Shelf houses the system’s common control cards including the Central Processing Unit (CPU) card and the Time Switch (TSW) card. • Only the TSW card is included with the Basic Shelf which includes the DOHCA and TSW-CONF cards • The CPU card is available separately.

  10. Basic ShelfKX-TD500 • 12 Free Slots (FS1-FS12) are available in the Basic Shelf and can be carded with CO, station, or other function cards as required by the installations application. • If the installation location requires more than the 12 slot configuration supports, the system can be expanded by attaching 2 additional Expansion Shelves to the upper portion of the Basic Shelf

  11. Basic Shelf Includes: • Top panel with 3 LED indicators (Run,Offline,Alarm) • 2 Female RS-232C connectors • One for Programming • One for SMDR • An AC Power connector

  12. Basic Shelf Includes: • Primary AC Power Supply with: • Main Power Switch • Grounding Terminal • AC outputs for Expansion Shelves • Shelf Power Supply with: • Power Switch • Power LED Indicator • Fuse • KX-A46 interface connector

  13. Basic Shelf Includes: • Shelf Cooling Fan • SLT Ring Generator • Mounting Brackets • Side Panels • Lower Panel • Front Door with Lock

  14. Expansion ShelfKX-TD520 • The KX-TD520 Expansion Shelf can be installed onto the Basic Shelf adding on a maximum of 216 additional ports. This provides a two-cabinet system with a maximum configuration of 408 ports. • A second Expansion Shelf could then be added bring the system up to its maximum port configuration of 512 ports.

  15. Expansion Shelves Include: • 14 Free Slots (FS1-FS14) • A Shelf Power Supply with: • Power Switch • Power LED Indicator • Fuse • KX-A46 Interface Connector • Shelf Cooling Fan • SLT Ring Generator

  16. Expansion Shelves Include: • Side Panels • Front Door with Lock • Data and Power Connecting Cables • Mounting Hardware

  17. TD500 Cards • Basic Cards • Basic Slot 1 = CPU Card, purchased from parts • Basic Slot 2 = TSW Card, Factory Installed • Extension Cards • Trunk Cards • Resource Cards • Other Cards

  18. KX-TD50101 CPU Card • 386-based Main Central Processing Unit Card residing in the Basic Shelf • This card provides control and call processing data for all system functions including TSW control, power down and system clock alarms • Main components include 80386 CPU, RAM, ROM, memory backup lithium battery

  19. KX-TD50101 CPU Card • CPU card also includes circuitry for the RS-232C connectors • “System” and “Mode” switches are 10 position rotary switches located on the front edge of the CPU card along with the push reset switch. • The “System” switch is not used in the US version.

  20. KX-TD50101 CPU Card • The “Mode” switch is used to determine the startup condition of the system. Although it is a 10 position switch, only 4 position are utilized for normal operations.

  21. KX-TD50101 CPU Card • Mode switch positions are: • Position 1 On-line while holding current data • Position 0,2,3,9 On-line Same function as 1 • Position 4 Off-line holding current data • Position 5 Off-line while defaulting system • Position 6 ON-LINE with “backdoor” password • Position 7 Off-line factory finished product testing • Position 8 Off-line factory finished product testing

  22. KX-TD50102 TSW Card • The Time Switch (TSW) card provides the systems voice switching matrix including 72 3- party conferencing circuits • The TSW card generates all audible call progress tones, including dial tone, busy tone, reorder and ringback tones

  23. KX-TD50102 TSW Card • The TSW card also provides an interface for 2 Music on Hold inputs (9/64” mini-plug) and 2 External Paging output jacks (RCA plugs) with volume adjustments • Two daughter boards are attached to the TSW card • KX-TD50104 • KX-TD50105

  24. TSW Cards • The KX-TD50104 TSW-CONF Expansion Card adds an additional 64 3-party conference circuit to the basic 8 provided by the TSW card • The KX-TD50105 DOHCA card allows for OHCA for Digital Proprietary station cards • Both of these cards play an important role in Digital Voice Mail integration

  25. TSW Card • The KX-TD50104 TSW-CONF card provides 3-party conferencing capability. This includes the three DPITS integration features Two-way Record, Two-way Transfer, and Live Call Screening. • Each of these features requires the use of conference circuit

  26. TSW Card • The KX-TD50105 DOHCA card provides for DPT OHCA by providing TSW circuitry to support the second “B” channel for DPT telephones and DPITS integrated voice mail ports • The KX-TD50105 DOHCA card must be installed for DPITS voice mail integration to work

  27. New KX-TD500 Cards include: • These cards will only operate in a KX-TD500 • KX-TD50170-Digital Hybrid Line Card (DHLC) • KX-TD50172-Digital Line Card (DLC) • KX-TD50175-Enhanced Single Line Card (ESLC) • KX-TD50180-Enhanced Loop Central Office Trunk (ELCOT) • KX-TD50197-Enhanced Remote Card (ERMT)

  28. KX-TD50170Digital Hybrid Line Card • The DHLC supports 8 analog proprietary telephones or 8 digital proprietary and 8 SLT telephones (XDP or parallel) • This card supports 7000 and 7400 series telephones as well as SLT’s • See right side of page 2-41 in Installation Manual for block wiring

  29. KX-TD50170Digital Hybrid Line Card • OHCA using the KX-T7436/7130 is supported without any additional cards installed on the station card. (The KX-TD50105 card must be installed on the TSW card for OCHA to the KX-T7436)

  30. KX-TD50172Digital Line Card • The DLC supports 16 digital proprietary telephones (7400 series) and DSS consoles • No SLT’s are will operate on this card • See right side of page 2-44 in Installation Manual for block wiring

  31. KX-TD50175Enhanced Single Line Card • The ESLC supports 16 single line telephones with Message Waiting Lamp compatibility • No proprietary telephones will operate on this card • ESLC has 4 DTMF receivers • See right side of page 2-42 in Installation Manual for block wiring

  32. KX-TD50180Enhanced Loop CO Trunk • The ELCOT card supports 8 Loop Start Central Office lines • When two optional KX-TD193 Caller ID cards are installed, Central Office Caller ID is provided to proprietary display telephones • See page 2-55 in Installation Manual for block wiring

  33. KX-TD50197Enhanced Remote Card • The ERMT card is a modem card (V.34) used for remote administration.

  34. Other Cards Supported by the KX-TD500 • The following cards were previously supported by the KX-T336, and in the case of the KX-TD193, the KX-TD816/1232, and provide the same functions and capabilities. • Refer to KX-TD500 optional card compatibility chart for more information

  35. Other Cards Supported by the KX-TD500 • KX-T96170 - 8 Station Hybrid Line Card (HLC) • KX-T96172 - 8 Station Proprietary Line Card (PLC) • KX-T96174 - 8 Station Single Line Card (SLC) • KX-T96175 - 8 Station Single Line Card with Message Waiting Lamp compatibility (SLCM) • KX-T96180 - 8 Loop Start Central Office Trunk card (LCOT) • KX-T96181 - 8 Ground Start Central Office Trunk card (GCOT)

  36. Other Cards Supported by the KX-TD500 • KX-T96182 - 4 DID Trunk card (DID) • KX-T96185 - 4 Station Off-Premise extension card (OPX) • KX-T96186 - Off Premise Extension Power Unit • KX-T96187 - T1 card (T1) • KX-T96161 - Doorphone card (DPH) • KX-T96191 - DISA card (DISA) • KX-T96193 - Automatic Gain Control card (AGC)

  37. Other Cards Supported by the KX-TD500 • KX-T96196 - 1200 bps Remote card (RMT) • KX-T96136 - OHCA card for HLC and PLC cards (OHCA) • KX-TD193 - Caller ID card for ELCOT card (CID)

  38. KX-T96170 • Hybrid Line Card (HLC) • Each card provides 8 Hybrid extension ports • Either a Analog Proprietary Telephones (7000 series) or a single line telephones can be connected to this card • See right side of page 2-41 in Installation Manual for block wiring

  39. KX-T96172 • Proprietary Line Card (PLC) • Each card provides 8 proprietary extension ports • Only Analog Proprietary Telephones (7000 Series) can be connected to this card • See right side of page 2-41 in Installation Manual for block wiring

  40. KX-T96174 • Single Line Telephone card (SLC) • Each card provides 8 single line extension ports • Only single line telephones can be connected to this card • See right side of page 2-41 in Installation Manual for block wiring

  41. KX-T96175 • Single Line Card with Message Waiting (SLC-M) • Each card supports 8 single line extensions with Message Waiting lamps • See right side of page 2-41 in Installation Manual for block wiring

  42. KX-T96180 • Loop Start Central Office Card (LCOT) • Each card allows 8 Loop Start Central Office lines to be connected to the system • See page 2-55 in Installation Manual for block wiring

  43. KX-T96181 • Ground Start Central Office Card (GCOT) • Each card allows 8 Ground Start Central Office lines to be connected to the system • See page 2-55 in Installation Manual for block wiring

  44. KX-T96182 • Direct Inward Dialing Trunk Card (DID) • Each card allows 4 DID Central Office lines to be connected to the system • This card will accept pulse signaling only • System interface is modular (RJ-11C)

  45. KX-T96185 and KX-T96186 • KX-T96185--Off Premise EXtension Card (OPX) • KX-T96186--Off Premise Extension Power Supply • An OPX card and Power Supply provides 4 OPX single line telephones only • Both OPX units are required when a single line telephone must be placed in another building or location • System interface is modular (RJ-11C)

  46. KX-T96187 • T-1 Card • Up to 8 T1 cards can be installed in the KX-TD500 • Frame Formats D4/SF or ESF • Line Coding AMI or B8ZS • Channel Types LCO/GCO/DID/OPX/TIE • System interface is RJ-48C (See page 2-53 in Installation Manual for cable configuration)

  47. KX-T96187 • The T1 card can only be installed in slots 1 (2), 5 (6), and 9 (10). • The slot immediately adjacent to the right of each T1 card must be left empty as indicated above by the slot number that are parenthesized.

  48. KX-T96161 • Doorphone card • Provides 4 Doorphones and 4 dry contact relays • 2 card per system

  49. KX-T96191 • Direct Inward Station Access card (DISA) • Each DISA card can be programmed to provide one of three functions. • Basic 4 port automated attendant or; • Outgoing Message for Uniform Call Distribution • Timed Reminder OGM • 8 DISA cards can be installed in the system

  50. KX-T96193 • Automatic Gain Control card (AGC) • Each card provides 4 gain controlled CO to CO conference circuits • 8 AGC cards can be installed in the system