460 likes | 615 Views
BUILDING ENVELOPE CONSULTING SERVICES. CONSTRUcTION COMPLIANCE TESTING Storm related roof damage assessments forensic investigations litigation support.
E N D
CONSTRUcTIONCOMPLIANCE TESTINGStorm related roof damage assessmentsforensic investigationslitigation support
Fm Global 1 – 52 Field uplift testsastm E 907 field testing uplift resistance of adhered membrane roofing systemsASTM E 1105 Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls
NEGATIVE PRESSURE TESTING SIMULATING WIND UPLIFT PRESSURE TO VERIFY RESISTANCE OF LOW-SLOPE MEMBRANE ROOFS FM GLOBAL 1-52 ASTM E 907
WIND WIND ACTS A FLUID FLOWING OVER AND AROUND STANTIONARY OBJECTS
WIND ~ 25 psf WIND CAUSES A POSITIVE PRESSURE ON THE WINDWARD SIDE OF THE OBJECT AND CAN CAUSE A NEGATIVE (UPWARD) PRESSURE ON THE ROOF 25 psf
BUR - DELAMINATION Poor Adhesion Between Insulation and Cover Board Poor Adhesion Between Cover Board and Membrane Poor Adhesion Between Deck and Insulation
Bur - DELAMINATION Poor Adhesion Between Cover Board and Membrane
TPO - DELAMINATION Poor Adhesion Between Insulation and Membrane
Before the storm… negative pressure testingCONSTRUCTION COMPLIANCE and risk assessment
NEGATIVE PRESSURE TESTING 5’ SQ Chamber Imposes an Uplift Force on the Membrane Pressure is Incrementally Increased to the Design Test Pressure Deflection of the Membrane is Measured and Compared to Performance Criteria
NEGATIVE PRESSURE TESTING Fastener holding adequately at test pressure
Application • Acceptance of new (including re-roofed and re-covered) above-deck roofing assemblies by FM Global…in regions that are both prone to hurricanes, typhoons or tropical cyclones and where design wind speeds are at least 100 mph (FM 1-52). • Field verification of adhesion of low-slope roof for the issuance of a certificate of insurability. For example WPI-8 for the Texas Department of Insurance (TDI). Negative pressure test
Application • Risk Assessment – as part of the evaluation of a property this test could be used to determine probable loss at incremental pressure (Hurricane Strengths). Negative pressure test
Curtain wall testingNew constructionforensic investigationsrisk assessmentdue diligence
CURTAIN WALL TESTING Rack Calibrated to Deliver 5 gal / sf / hr
CURTAIN WALL TESTING Pressure Differential Imposed Across System
CURTAIN WALL TESTING Water Infiltration
Forensic – component isolation The Forensic Version of the Test Allows For Isolation of Various Components to Determine Mode of Failure.
Forensic – component isolation IR Images During Test Help Indentify Path of Water Intrusion
Forensic – component isolation IR Images During Test Help Indentify Path of Water Intrusion
Destructive observations…sometimes you just need to open the wall and see what is happeningforensic investigationslitigation support
WATER INFILTRATION INVESTIGATIONS Remove Finish Materials
WATER INFILTRATION INVESTIGATIONS Document MC of Framing
WATER INFILTRATION INVESTIGATIONS Run Component Isolating Water Test to Determine Mode of Failure
BUILDING ENVELOPE SURVEYNew constructionlitigation supportforensic investigationsrisk assessmentdue diligence