1 / 12

Cirrus HD-OCT. Small footprint and 90 degree orientation Mouse driven alignment

Cirrus HD-OCT. Small footprint and 90 degree orientation Mouse driven alignment Auto patient recall Repeat scan function Precise registration for clinical confidence Advanced optics for scanning of patients with cataracts or pupils as small as 2.5mm. CIRRUS HD-OCT

kyrie
Download Presentation

Cirrus HD-OCT. Small footprint and 90 degree orientation Mouse driven alignment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cirrus HD-OCT. • Small footprint and 90 degree orientation • Mouse driven alignment • Auto patient recall • Repeat scan function • Precise registration for clinical confidence • Advanced optics for scanning of patients with cataracts or pupils as small as 2.5mm

  2. CIRRUS HD-OCT • Features provide clinical utility and increase efficiency: • RNFL Thickness Analysis • RNFL Normative Data • 3D Volume Rendering • Custom 5-line Raster Scan • High Definition Cross Scan • Segmentation Editing Tool • Precise registration

  3. PreciseRegistration: • Real Time Registration between OCT and LSO Fundus • Visit-to-visit Registration using the LSO overlay from previous visit • Optic Disc Registration automatically centers the RNFL TSNIT circle around the disc

  4. Glaucoma RNFL thickness analysis: • Center of disc is automatically identified for precise registration and repeatability • RNFL thickness display is of a 1.73mm radius circle around the disc • TSNIT graph is compared to normative database

  5. The RNFL deviation map is overlaid on the OCT fundus image to illustrate precisely where RNFL thickness deviates from a normal range The RNFL thickness map shows the patterns and thickness of the nerve fiber layer.

  6. 3D Volume Rendering

  7. Using the mouse, you can Fly through, rotate the 3D image

  8. 3D Volume Adjustment controls allow manipulation of cube image. Here the cube has been peeled back to reveal the RPE layer

  9. Here a slice, or C-plane, of the inner retina is revealed.

  10. Custom 5line – RasterScan Can be adjusted for orientation ,Rotation, length of lines and height of scan area

  11. The Tissue Layer image allows you to isolate and visualize a layer of the retina. The thickness and placement of the layer are adjustable. This provides a virtual dissection of the retina by extracting the layer of interest

  12. RPE Layer Map HD Thickness Map ILM Layer Map • Cirrus HD-OCT. • reveals • HD layer maps • ILM layer map • RPE layer map • HD Thickness Map • Tissue layer map

More Related