Analysis of Tagger high resolution TDC for separating RF

Analysis of Tagger high resolution TDC for separating RF. 2004. 7. 14 Hideki Kohri. Mass spectrum. r29511 - 29514. Momentum (GeV/c). Although we started taking high resolution TDC data of tagger PL for improving mass spectrum, the mass spectrum was improved

lacy-buck
Download Presentation

Analysis of Tagger high resolution TDC for separating RF

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Analysis of Tagger high resolution TDC for separating RF 2004. 7. 14 Hideki Kohri

  2. Mass spectrum r29511 - 29514 Momentum (GeV/c) Although we started taking high resolution TDC data of tagger PL for improving mass spectrum, the mass spectrum was improved by considering the flight time between target and start counter. But the TDC data of tagger PL can be also used for TPC trigger counter. Mass / charge GeV/c2

  3. Tagger high resolution TDC analysis Tagger PL#3 ADC ADC rfrawTDC-TagTDC After slewing correction TDC channel TDC channel RMS 330ps What makes tail? TDC channel SUM

  4. Correlation between two PL’s Tagger multiplicity 2 events RF bunch number PL#3 RF bunch number PL#2 RF bunch PL#3 - PL#2 # of +1 / # of 0 = 3.3 % # of -1 / # 0f 0 = 4.5 %

  5. Pion events Good pions: Pions whose RF is correctly identified by LEPS spectrometer Solid : good pions Dashed: bad pions RF number LEPS - TaggerPL RF number LEPS - TaggerPL Momentum (GeV/c) Abilities of start counter and tagger PL for separating RF are not so different. Advantage of using tagger PL TDC for forward spectrometer analysis seems to be small. But it would be a help for TPC analysis. Mass/charge GeV/c2

  6. RF timing shift ?

  7. Particle ID by new start counter r29552 - 29556 Sigma = 28 MeV/c2 Momentum (GeV/c) Mass / charge (GeV/c2) There are some events whose RF is not correctly identified. Currently, it is difficult to say that new start counter is better than old one. Mass / charge GeV/c2