An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High Resolution Melting What is it ? How does it work ? Jason McKinney Scientist

  2. Scanning for sequence variants • “Scanning” = SNP discovery, rare alleles • “Genotyping” = discriminate between known alleles, common mutation • Scanning based on detection of “HETERODUPLEXES”

  3. What is a “Heteroduplex” ?

  4. Scanning (continued) • Based on detection of heteroduplexes • Different from fully base paired molecules • Mobility (SSCP, DGGE, CGGE) • Thermal stability (dHPLC) • Sequencing (gold standard)

  5. Effective methods, however, … • Time consuming • Labor intensive • Technical skills • Equipment / Start up cost • … can we build a better “mouse trap” ?

  6. Fluorescent Melting Curve analysis? • Identify heteroduplexes based on the change in fluorescent signal as a sample is thermally denatured (melted) • Dye that “glows” when bound to dsDNA • Wait a second, … haven’t people tried this already ? • Well, … yes, … it didn’t work very well.

  7. What is a Melting Curve?

  8. Melting with Sybr Green Lipsky, et al., Clin Chem 2001

  9. WHY it did not work • 2 Primary Reasons • (1) Chemistry • Fluorescent dyes inhibit PCR at “SATURATING” concentrations • (2) Instrumentation • Slow data acquisition rates, optically inferior instrument, inadequate temperature control

  10. HR-1 and LCGreen Instrument and Chemistry solutions

  11. What is a “Saturating” dye ?

  12. Melting with LCGreen

  13. HR-1 Data acquisition (>100 pts/degree @ 0.30C/sec, fast) Temperature control (+/- 0.050C) Custom optics (matched to LCGreen, dedicated) LightCycler <10 data points/degree @ 0.10C/sec +/- 1-20C Generic optics, meant to be able to detect a range of fluorophores, focal distance and/or angle may change between samples HR-1 vs. LightCycler

  14. HR-1 LightCycler Melting curves: HR-1 vs. LC

  15. Summary • Scanning for heteroduplexes • New twist on an old game • Melting curve, sequence of events • HR-1, LCGreen, … solves 2 issues • Saturating dye • Data acquisition • Scanning is NOT Genotyping