150 likes | 313 Views
Asahi/America Constant Flow Valves. 1/2”,3/4”. 1”,2”,3”,4”. Spring. Plug. Orifice. Spring. Orifice. Plug. Asahi/America Constant Flow Valves. PVC & CPVC ANSI Flanged. Y Type. In Line Type. Asahi/America Constant Flow Valves. Features & Benefits.
E N D
1/2”,3/4” 1”,2”,3”,4” Spring Plug Orifice Spring Orifice Plug Asahi/AmericaConstant Flow Valves PVC & CPVC ANSI Flanged Y Type In Line Type
Asahi/AmericaConstant Flow Valves Features & Benefits High durability and resistance to chemicals High accuracy Flexible flow rate Opening degree indicator High durability and resistance to chemicals The spring is made of stainless steel with coating of PCTFE. ETFE acts as an excellent gas barrier to chemicals such as Cl2,HF,HNO3,HCL and so on. The superior durability has been proven by conducting a repeated spring fatigue test .(1 Million cycles)
Flexible flow rates Opening degree indicator Calibrated Flow Dial Asahi/AmericaConstant Flow Valves
Asahi/AmericaConstant Flow Valves 1/2”, 3/4”, 1”, 2”, 3” ,4” Nominal Size Body material PVC (Unplasticized Polyvinyl Chloride) Flange connection ANSI, DIN etc. (Please specify according to upstream pressure) Upstream line Pressure ranges. Types Under 35 psi 36 - 70 psi 71 - 110 psi 111 - 150 psi 2.85 - 14.22 psi : Type A & B 4.27 - 21.33 psi : Type D (only 3”) 4.27 - 28.45 psi : Type C Pressure differential range for function: Working Temp. : 30 - 120 °F
Asahi/AmericaConstant Flow Valves Rangeability
Flow Flow Asahi/AmericaConstant Flow Valves Type - A Fluid flows through the valves internals Suitable for semi-conductor.(Ultra pure water line) Type - B Flow rate setting range is large. (Covers small flow rates to large flow rates)
Flow Flow Asahi/AmericaConstant Flow Valves Type - C Range of working differential pressure is large . (For lines with large pressure differential between upstream & downstream) Type - D A large flow rate can be set.
Asahi/AmericaConstant Flow Valves P1 P2 P2
Asahi/AmericaConstant Flow Valves High accuracy Flow Quantity It is possible to change the flow quantity by changing the position of the plug. Pressure Differential
Asahi/AmericaConstant Flow Valves C type (2”) B type (2”) 39.6 39.6 35.2 35.2 30.8 30.8 26.4 26.4 Flow (gal/min) 22.0 Flow (gal/min) 22.0 17.6 17.6 13.2 13.2 8.8 8.8 4.4 4.4 0 0 2.85 5.7 8.6 11 14.22 11.4 14.3 17.1 20 22.9 25.7 28.6 31.4 34.3 37.1 8.6 2.85 5.7 Differential Pressure (psi) Differential Pressure (psi) 2.85 psi - 14.22 psi 4.27 psi - 28.45 psi
Q1 LINE A Q1+Q2 Q2 LINE B Asahi/AmericaConstant Flow Valves Parallel Lines CV = Q Ö[s.g. / DP] (Q = flowrate (gpm) s.g. = specific gravity)
< Fish Farms > <Aquariums> AV Constant Flow VALVE sea water tank Asahi/AmericaConstant Flow Valves
Asahi/AmericaConstant Flow Valves Applications: < Salt Water > The protection of ion-exchange membranes. Flow quantity is fixed. No Automation or Manual Adjustment Required
Asahi/AmericaConstant Flow Valves Water Supply or Filtration AV Constant Flow VALVE Water supply equipment