Status of data retrieval (SSS and S4 tested in SM18).

Status of data retrieval (SSS and S4 tested in SM18). Data retrieval : goals, agenda. Procedure of data treatment and validation Status of the data treatment (20/02/07). Number of quadrupoles to be treated. MQ: 28 MQ (transfer function, multipoles).

lane-gross
Download Presentation

Status of data retrieval (SSS and S4 tested in SM18).

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status of data retrieval (SSS and S4 tested in SM18). • Data retrieval : goals, agenda. • Procedure of data treatment and validation • Status of the data treatment (20/02/07).

  2. Number of quadrupoles to be treated. • MQ: 28 MQ (transfer function, multipoles). • MQM : 4 MQM (transfer function, multipoles) • The other MQM were measured in Block 4 and treated by W.Venturini. • MQY : 12 MQY (transfer function, multipoles) • MQY measured in Block 4 will be treated by W.Venturini. • MQTL (Q6): 1 measured completely in SM18. 45 magnets to be treated in total.

  3. What we will get after the retrieval. • 4 reference tables corrected and entered in the SMA web site. • Transfer function: TF for currents between injection and nominal in ramp up and ramp down (systematic correction with SSW measurements) • Integrated harmonics: Integrated strength and multipoles between injection and nominal in ramp up and ramp down. • Integrated components: Geometric, saturation, magnetization, hysteresis, decay (when it is measured). • Variation of the b2 and multipoles with time during the reference machine cycle (format table integral_harmonic) • Agenda • For MQ in arc SSS : ready end of February. • For MQY and MQM : ready end of March.

  4. Cleaning procedure. • Re-analysis of the raw data coming from machine cycle and load-line. • Transfer function • Check/correct the offset based on SSW measurements • Correct jumps in transfer function along the loadline in particular around 2000-3000 A • Add the ramp down YF=f(I). • Angles • Introduction of the Mag_fid angle measured with the SSW (table provided by Marco Buzio) • Harmonics • Add the multipoles as a function of the current (ramp up and down) • Multipoles components • Check of the components • Ramp rate effect added when measured • Decay file prepared (variation of the b2 and multipoles with the current for the reference cycle). • Final checks • Creation of a log file including offsets, angles, comments.

  5. Transfer function correction :extreme case. Raw data Strength correction based on SSW cross-check + jump at low current corrected. Correction confirmed by another measurement with re-calibrated amplifiers Criteria : Correction performed when the jump is higher than 1 unit.

  6. Status of the MQ, MQM, MQY treatment. • MQ: 16 treated/ 28 the 20/02/07. • Second run of checking is needed at the end. • No MQM and MQY for the moment.