1 / 15

UPGRADATION REHABILITATION OF EXTERNAL PLANT, POLELESS SCHEME

. Improper cable works and lack of Co-ordination with other public utility services in cable construction wings.II. Incomplete and sometimes absence of documentation and records, and negligence of preventive as well as annual maintenance of external plant.III.Use of the poor quality material and

lars
Download Presentation

UPGRADATION REHABILITATION OF EXTERNAL PLANT, POLELESS SCHEME

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. UPGRADATION & REHABILITATION OF EXTERNAL PLANT, POLELESS SCHEME

    2. Improper cable works and lack of Co-ordination with other public utility services in cable construction wings. II. Incomplete and sometimes absence of documentation and records, and negligence of preventive as well as annual maintenance of external plant. III. Use of the poor quality material and poor workmanship.

    3. For better Mtc. Of Extl Plant Adequate provision of funds in the project for external plant and proper planning of cabling. Adoption of better cable construction practices. Protection of external plant from power induction. Use of good quality telephone instruments in subscriber’s premises.

    4. Ensuring periodical inspections by officers concerned at various levels Opening of customer service center and responding promptly to communications from public/subscribers. Computerization of commercial Management system

    5. Use of Drop wire with Accessories. Preventive Maintenance Methods Patrolling of Cable Routes

    6. REDUCTION OF FAULT RATE IN EXTERNAL PLANT Poless Technology

    7. Maximum Over head lines exist Maximum faults are booked and noticed Many overhead road and power crossing exist. DPs are in bad condition due to traffic congestion. Different gauge drop wires exist. Many DPs for which the Phone Mechanic is Removing the pair from DP termination and twisting the UG cable pair to Drop wire directly. Non feasible areas exist. High telephone density exists One subscriber is a custom

    8. For Acceptance Testing of External plant the following should be physically inspected and tested Cabinets and pillars. b. Pole- Mounted DP c. Internal DP d. Service line. e. Indoor House Wiring g. Electric Parameters of Line h. Dial of subscriber’s instrument

    9. The Cabinets /pillars should be located at obstruction free place on concrete base and height should be above flood level. The cabinet / pillars should be numbered properly General condition of the plant outside and in side should be without any rust. The doors should open and close freely. The cabinet/pillar should be neat & clean from inside. The cabinet/pillar shell should be firmly fixed and bolts should be tight.

    10. CT Box should be fixed firmly to the frame and all fixing screws should be tight. The jumper field should be tidy there should not be unnecessary long. The position of spare pairs should be according to the records. all the records should be available in the cabinet /pillar. There should be no dust. cobwebs inside the cabinet/ pillar. Check the locks.

    11. DP should be located at obstruction free place and no way in the vicinity of electric poles etc. The DP should be painted and numbered. Minimum height of DP should be 9’feet (2.75M) from the ground. The DP should be properly fitted to the post by means of standard U back and saddles. The back of the U backs should be flattered for giving good grip on the tubular posts. The cable should be taken to DP base through GI pipe of 50 mm internal diameter.

    12. Earthing arrangement should be provided. Updated DP cards should be available. The drop wire lead should be properly secured on the wooden batton / board. The DP should have locking facility. A bracket should be provided below the DP to facilitate maintenance. The lowest bracket on DP pole should be fitted at the minimum height 2.75m from the ground. All the brackets should be fitted with ties and struts. DP Post should be fitted with proper stays

    13. 100 % Dps should be checked. The height of the line terminating / Distribution tag block/internal DP should be approximately 2.5M above the floor. The same should be on the inside wall building and easily accessible for inspection. Location for telephones termination box should be different from that of the power meter. Where it is unavoidable, a minimum distance of 1M between the two should be insured.

    14. Subscribers loop resistance. Limit for E-10B Exchange - 1500?

    15. Electric Parameters and Dial Test in E-10B Exchanges The TTY gives Print out by ABESL command.