1 / 17

Implementing the Rating – ADAPS

Implementing the Rating – ADAPS. Streamflow Records Computation using ADVMs and Index-Velocity Methods Office of Surface Water. Overview. Stage-area rating Simple-linear index rating – equation Compound-linear index rating Multiple-linear index rating Stage-discharge rating.

lazaro
Download Presentation

Implementing the Rating – ADAPS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Implementing the Rating – ADAPS Streamflow Records Computation using ADVMs and Index-Velocity Methods Office of Surface Water

  2. Overview • Stage-area rating • Simple-linear index rating – equation • Compound-linear index rating • Multiple-linear index rating • Stage-discharge rating

  3. Stage-Area Rating

  4. Stage-Area Rating Discharge data descriptor must be chosen. No ratings (except for conversion of input rating) should be put under velocity

  5. Stage-Area Rating

  6. Stage-Area Rating Assure the stage-area rating (and any other rating used) starts on or after the day of the index-velocity processor

  7. Simple-Linear Index Rating

  8. Simple-Linear Index Rating • Example • Vcomp = .9213 * Vi - .0136

  9. Compound-Linear Index Rating • Same ADAPS procedure as the stage-area rating • Choose the VELO rating type • Value in – index velocity • Value out – computed velocity • Example • Velocity < 0 Vcomp = .89 * Vi • Velocity >0 Vcomp = .95 * Vi • Assure the rating covers the entire range of conditions that are expected at the site

  10. Multiple-Linear Index Rating • These are equations in the form of • y = aX1 + b(X1*X2) + c • Y = computed velocity • a = slope coefficient for X1 • b = slope coefficient for X2 • c = y intercept • X1 = index velocity • X2 = stage

  11. Multiple-Linear Index Rating

  12. Multiple-Linear Index Rating

  13. Multiple-Linear Index Rating

  14. Multiple-Linear Index Rating

  15. Multiple-Linear Index Rating • Vcomp= 0.462X1 + 0.033(X1X2) + 0.099

  16. Stage-discharge rating • Processor Status: working • Created by: edebiak on: 10-08-2003 @ 16:41:57 EDT • Modified by: edebiak on: 10-09-2003 @ 11:05:18 EDT • SD - Starts on: 01-01-1800 • ED - Ends on: 12-31-2382 • RP - Default primary report type: Standard • GP - Unit values missing gap time: 60 (MINUTES) • DV - Compute DVs: MEAN • IS - Stage gage: DD #02 Gage height PUBLISHED (ft) • IV - Velocity gage: DD #07 Stream velocity linear rating • UL - Upper gage height limit: Not specified • LL - Lower gage height limit: Not specified • EQ - Use mean-velocity equation: No • XC - Equation X coefficient: Not specified • YC - Equation Y coefficient: Not specified • EC - Equation constant: Not specified • HB - Base for extreme events: Not used • HP - Interval for extreme events: Not used • SV - Site Visit Computation Flag (Y/N): Y To use a stage-discharge rating above a certain gage height, put the gage height in the UL field. The LL field is filled in to use a stage-discharge rating below a certain gage height. The stage-Q rating is put into the same discharge data descriptor as the velocity ratings. Shifts can be entered as well

  17. Questions? • Complex ratings can be implemented outside of ADAPS using a script. Details for this can be found in appendix 6 of the T&M

More Related