1 / 10

ELT-400

ELT-400. Overview. EN 50366 Comparison ELT-400 Competitive Instruments USPs Success Stories with ELT-400 New 3 cm² Probe Roadmap ELT-400. EN 50366 Requirements ELT-400 compliance to EN 50366. EN 50366. EN 50366 requirements (1). Legal situation:

Download Presentation

ELT-400

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ELT-400

  2. Overview • EN 50366 • Comparison ELT-400 • Competitive Instruments • USPs • Success Stories with ELT-400 • New 3 cm² Probe • Roadmap ELT-400

  3. EN 50366 Requirements ELT-400 compliance to EN 50366 EN 50366

  4. EN 50366 requirements (1) • Legal situation: • EN 50366 is ready, last signature has been done by the end of 2004. Now it's law without transitional period. • Each manufacturer looking for CE approval has to check against EN 50366. And the easiest check is the measurement with ELT-400.

  5. EN 50366 requirements (2) • Scope: • Electric and magnetic field around household electrical appliances • Measuring methods (only magnetic fields): • 10 Hz to 400 kHz • Isotropic measurement with 100 cm² probe • Reference method: Time domain evaluation • Measurement uncertainty: • less than 25 %

  6. ELT 400 meet EN 50366 standard • Requirements • according to • EN 50366: • 10 Hz – 400 kHz • 100 cm² probe • Evaluation based on • time domain • < 5 % • 1 sec. • < 2 sec. • Frequency range: • Measuring probe: • Reference measuring • Method: • Intrinsic noise: • Averaging time: • Settling time: • Features of • ELT-400 • (1…) 10 Hz – 400 kHz • 100 cm² probe (isotropical) • Direct transfer (through • Shaped Time Domain STD) • typical 0,4 % • 1 sec. • ca. 1 sec.

  7. ELT-400 compliant to EN 50366

  8. ELT-400 Competition

  9. pole position Unique Selling Points ELT-400 • Frequency range: • 1 Hz – 400 kHz • Broadband field strength measurements: • Extended meas. range (up to 80 mT) • Direct indication in Tesla • STD - Simple evaluation of magnetic fields: • Unique implementation of reference method • Direct indication as weighted result in % • Active 3-channel probe: • Display signal shapes on a separate oscilloscope, FFT analyzer • Handling: • Simple operation and rugged housing • Battery power • 100 cm2 probe: • Standards-compliant • Stipulated for inhomogeneous fields • 3 cm² probe: • Standards-compliant • only Probe on the Market

  10. 1 2 3 Measurement with 100cm² probe Coupling Factor available Determination of Coupling Factor by 3cm² Probe No Determination of Individual Coupling Factor by 3cm² Probe Yes Conform to EN 50366? Multiply Result with Coupling Factor No Conform to EN 50366? Yes No Conform to EN 50366? Yes No Yes Comply  Failed EN 50366 – Three Chances!