Agenda. RequirementsShipping ContainersTransportation MonitoringTower Storage. Requirements. DocumentationLAT-SS-00778, LAT Environmental SpecificationLAT-SS-00134, Tracker Level IV SpecificationLAT-MD-00228, LAT Contamination Control PlanFull performance testing before and after shippingFul
E N D
2. Agenda Requirements
Shipping Containers
Transportation Monitoring
Tower Storage
3. Requirements Documentation
LAT-SS-00778, LAT Environmental Specification
LAT-SS-00134, Tracker Level IV Specification
LAT-MD-00228, LAT Contamination Control Plan
Full performance testing before and after shipping
Full documentation delivered with Towers
4. Shipping Containers Double containment
Inner container attaches to vibration fixture
Aluminum rods at each corner of vibration fixture
Aluminum plates with high density foam
Data logger attached to vibration fixture
Cables secured under tower
Outer Container
Two pieces
High impact plastic
4 inches of high density foam all around
5. Transportation Monitoring
6. Tower Storage Inner shipping container used for storage
At SLAC towers will be stored in clean room, in inner container, prior to integration
Outer shipping containers and data loggers will be reused