1 / 9

Wind Tunnel Specifications

Wind Tunnel Specifications. 50kW synchronous AC motor, centrifugal fan Vertical diffuser, area ratio 2.87 Horizontal diffuser, area ratio 2.65 Settling chamber 2650 x 2150 x 2500mm length Contraction, area ratio 11.4 Working section, 1000x500mm outlet, open sided

lefty
Download Presentation

Wind Tunnel Specifications

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Wind Tunnel Specifications • 50kW synchronous AC motor, centrifugal fan • Vertical diffuser, area ratio 2.87 • Horizontal diffuser, area ratio 2.65 • Settling chamber 2650 x 2150 x 2500mm length • Contraction, area ratio 11.4 • Working section, 1000x500mm outlet, open sided • Four plastic screens (open area ratio 0.65) fixed in the fan adaptor and diffuser sections • Aluminium Honeycomb in the settling chamber, 50.8mm thickness, 6.3mm cell size

  2. Flow Uniformity • Flow velocity contours at tunnel outlet without working section 5 m/s 10 m/s 15 m/s

  3. Flow Uniformity • Flow velocity is within 1% of mean velocity across the 1m x 0.5m working section outlet Velocity contours in working section 5 m/s 10 m/s

  4. A B 200mm Horizontal Wind Gradient • Mean pressures A & B measured simultaneously with two pitot-static tubes spanning 200mm at the anemometer cup location. Procedure repeated with p-s tubes reversed. • Linear regression shows 0.3% difference in pressure

  5. Turbulence Measurements single normal hotwire Pitot-static tube (design similar to AMCA type) anemometer & filter (5kHz) Pressure Transducer Ashcroft XLdp Analog-Digital Converter NI PCI-6013 (16 bit) PC

  6. Turbulence Intensity Turbulence Intensity

  7. Wind Tunnel Turbulence Spectra

  8. p-s probe location Cup Anemometer Calibration Setup

  9. Calibration Procedure Pitot-static tube (design similar to AMCA type) • Risoe P2546A cup anemometer calibrated using the Measnet procedure • No blockage included for Newcastle result Pressure Transducer Ashcroft XLdp HP Frequency Counter Analog-Digital Converter NI PCI-6013 (16 bit) PC

More Related