1 / 12

- 160(W) × 90(H) × 30(D)mm

192 x 64 dot Graphic LCD. Compact Size. ABCDEFGHIJKLMNOPQRSTUVWX ABCDEFGHIJKLMNOPQRSTUVWX ABCDEFGHIJKLMNOPQRSTUVWX ABCDEFGHIJKLMNOPQRSTUVWX. - 160(W) × 90(H) × 30(D)mm. Built-in 256K Flash Memory (Screen and Font). DIP S/w. DC 24V. RS-422/485. RS-232. GLOFA PANEL H/W.

leigh
Download Presentation

- 160(W) × 90(H) × 30(D)mm

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 192 x 64 dot Graphic LCD Compact Size ABCDEFGHIJKLMNOPQRSTUVWX ABCDEFGHIJKLMNOPQRSTUVWX ABCDEFGHIJKLMNOPQRSTUVWX ABCDEFGHIJKLMNOPQRSTUVWX - 160(W) × 90(H) × 30(D)mm Built-in 256K Flash Memory (Screen and Font) DIP S/w DC24V RS-422/485 RS-232 GLOFA PANEL H/W 1. GLOFA PANEL H/W GLOFA PANEL H/W Features PMU Editor Comm. System Comparison Screen download and User-defined RS-232C User-defined RS-422/485 DC24V Input Variable resistance for contrast adjustment S/W for O/S download

  2. GLOFA PANEL Features 2. GLOFA PANEL: User-interface • Language support: • * Font-download type adopted -> English, Chinese, Korean • Flexible to supply power • * 5V supply by loader port: LG PLC and INV • * DC24V supply by DC24V input terminal • Easy to use (User-interface) • * Flexible to draw in 192*64 Dot Graphic LCD • * Easy to upgrade by adopting O/S and font downloading method • * Various tag/draw functions support (15 types) • * Internal memory (1000 words) support for easily assigning data • * User-defined function keys support for each screen (F1 ~ F4, ,,,) • * User-defined bit map file input support • * Region-based upload/download support • - Available to read/write screen, bit map, string, parameter, global and, constant, respectively • - Flexibility of project management and modification • * Built-in RTC: B Type • * Efficient screen memory: 256K • High-speed Interface support: 115,200bps (downloading speed) GLOFA PANEL H/W Features PMU Editor Comm. System Comparison

  3. GLOFA PANEL Features 2. GLOFA PANEL: Strong communication and security functions • Strong communication functions • * Separate 2Ch support: RS-232C and RS-422/485 • * Multi master communication (N:M) support • - Monitoring M PLCs with N GLOFA PANELs • Various communication modes and protocol driver supply • * Loader and dedicated protocol for Master K / GLOFA GM • * LG Inverter Loader protocol • * MODBUS MASTER (ASCII / RTU) Protocol • * Mitsubishi Melsec FX Series • * OMRON CPM/CQM Series (C-Mode protocol) • * NAIS FP Series (MEWTOCOL) • * Slave communication mode support: MODBUS Slave (ASCII / RTU), Dedicated Slave • * Siemens PPI Protocol: available from version 1.1 • Guarantee to add other communication driver • * Other communication protocol support in case of a major user’s request • Strong security function: maximise project security • * Password function: 10-digit password including number and English (capital, letter) • * Dual password support for developer (project access) and operator GLOFA PANEL H/W Features PMU Editor Comm. System Comparison

  4. GLOFA PANEL Programming Tool: GLOFA EDITOR 3. GLOFA EDITOR: Screen configuration GLOFA PANEL H/W Features PMU Editor Comm. System Comparison Menu and Tool Screen Edit Window Edit Window Attribute Set Window

  5. GLOFA PANEL Programming Tool: GLOFA EDITOR 3. GLOFA EDITOR: Features GLOFA PANEL H/W Features PMU Editor Comm. System Comparison • Region download support • * Download time enhancement to download the necessary region only • Color setting according to region • * Basic colors in Windows support and a user is able to set its color • Draw tool function • * Draw function support such as line, circle, square, etc • Easy memory management • * Memory usage display makes it easy to know the memory used and available • Snap/Align function support • * Snag and align functions for each tag support • Print function • * Each screen print function support: available from version 1.1

  6. 목표수량 150 목표수량 150 생산수량 75 目標數量 目標數量 150 75 Present Value GLOFA PANEL Programming Tool: GLOFA EDITOR 3. GLOFA EDITOR: Edit Window • Font size and language of editing letter • * Font size (1, 2) support • * Font-download method adoption: English, Chinese, Korean GLOFA PANEL H/W Features PMU Editor Comm. System Comparison

  7. GLOFA PANEL Programming Tool: GLOFA EDITOR 3. GLOFA EDITOR: Edit Window • Various tags support • * Lamp, button, number, character, message, bar graph, XY graph, Pie graph, bit map, line, square, circle, circulation, move, RTC tag, etc GLOFA PANEL H/W Features PMU Editor Comm. System Comparison

  8. GLOFA PANEL Programming Tool: GLOFA EDITOR 3. GLOFA EDITOR: Communication parameter setting • Comm. device selection and comm. parameter setting per each channel • * Separate two channel support: RS-232C and RS-422/485 GLOFA PANEL H/W Features PMU Editor Comm. System Comparison

  9. GLOFA PANEL II Ch1: Dedicated master Ch2: MODBUS slave GLOFA PANEL I Ch1: Dedicated master Ch2: MODBUS master RS422 MODBUS Dedicated Dedicated RS-232C RS-232C MK120S Ch1: Dedicated slave Ch2: Dedicated INV RS-485 RS-485 Dedicated VFD mode Dedicated VFD mode GLOFA PANEL Comm. system configuration 4. System configuration example • Ch 1 (RS-232C): Comm. with K120S (dedicated) • Ch 2 (RS-422/485): Comm. between GLOFA Panel간 접속(MODBUS) • RS-485 of K120S (Dedicated VFD protocol): Inverter Multi-drop Comm. GLOFA PANEL H/W Features PMU Editor Comm. System Comparison

  10. Master: 0 Master: 1 Master: 2 RS-232C RS-232C RS-232C LG INV loader Omron C-mode FX2N CPM2A RS-485 Dedicated comm. Melsec FX Slave: 3 Slave: 4 Slave: 5 GLOFA PANEL Comm. system configuration 4. System configuration example: Multi-master Comm. • Ch 1 (RS-232C): Comm. among 3 GLOFA PANELs, INV, CPM2C, and FN2N, respectively • Ch 2 (RS-422/485): Comm. among 3 GLOFA PANELs and 3 K120S (Dedicated Protocol) GLOFA PANEL H/W Features PMU Editor Comm. System Comparison GLOFA PANEL I Ch1: INV loader comm. Ch2: N:M ded. comm. GLOFA PANEL II Ch1: OMRON C-mode Ch2: N:M ded. comm. GLOFA PANEL III Ch1: Melsec FX Ch2: N:M ded. comm.

  11. Comparison with other HMIs 5. Comparison table GLOFA PANEL H/W Features PMU Editor Comm. System Comparison

  12. Comparison with other HMIs 5. Comparison table GLOFA PANEL H/W Features PMU Editor Comm. System Comparison