3-Channel-Electrocardiograph-AM-EGA15

Abimed 3-channel electrocardiograph offers precise results with a high-resolution color LCD. It performs 12-lead ECGs in manual, auto, and arrhythmia analysis modes, featuring a measurement range of 1u20135 mVp-p and a frequency response of 0.05 Hzu2013150 Hz.

lindahaley
Download Presentation

3-Channel-Electrocardiograph-AM-EGA15

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 3-Channel Electrocardiograph AM- EGA15

  2. www.abimed.com | info@abimed.com

  3. Overview 3-Channel Electrocardiograph AM-EGA15 offers clear and accurate results with its high-resolution colour LCD. It performs 12 lead ECG with three different modes i.e. Manual, Auto and Arrhythmia Analysis. The USB disk and SD memory make it convenient for the transmission and accessibility of patient's data. Specifications: Acquisition Mode Simultaneous 12 leads acquisition Measurement Range 1 ~ 5 mVp-p Time Constant ≥ 3.2s Frequency Response 0.05Hz ~ 150Hz Sensitivity 2.5, 5, 10, 20 mm/mV Input Impedance ≥50MΩ Input Circuit Current ≤ 0.05 µA Noise Level < 15 µVp-p Anti-baseline Drift Automatic Patient Current Leakage < 10 µA CMRR ≥120dB, with AC filter AC Filter: 50Hz / 60Hz Filter EMG Filter: 25Hz / 45Hz Anti-Drift Filter : 0.15Hz (Adaptive) Recording Method Thermal Printing

  4. RecordingPaperDimension 80 mm x 20 m Paper Speed 6.25, 12.5, 25, 50 mm/s; ± 3% Class II CF applied part, there is defibrillation and pacing protection circuit in it. Safety Standard Input Circuit Floating and defibrillation protection Sample Rate 100 Hz Built in Rechargeable Li-ion battery Power Supply Adaptor 110-230V, 50/60Hz AC power supply Unit Dimension 338 x 280 x 85 mm Unit Weight 3.5 kg Features: -5” LCD Display -Manual, Arrhythmia Analysis and Auto working modes -80 mm 3-Channel recording with rhythm lead -Optional: Built-in USB/RS232 interface (ECGNET software) StandardAccessories: Patient cable 1set Limb electrode 1set Chest electrodes 1set Grounding cable 1set Paper axis 1set Thermal paper 1set 2 Fuse

  5. 3-cord power cord 1set AC Adaptor 1set Applications: It is mainly used by health professionals in hospitals and Research centers to detect the Atrial fibrillation, bradycardia, tachycardia, normal heart rhythm and certain arrhythmias that are the leading indicators of cardiovascular diseases. Abimed Inc USA. Email: info@abimed.com | Website: www.abimed.com