1 / 28

High energy perspectives (and conclusions)

High energy perspectives (and conclusions). Philippe Ferrando APC Laboratory (UMR 7164) - Service d’Astrophysique CEA/Saclay. APC Conference High Energy Phenomena in the Galactic Center June 17, 2005. The Galactic Centre : an exciting and growing field.

Download Presentation

High energy perspectives (and conclusions)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High energy perspectives (and conclusions) Philippe Ferrando APC Laboratory (UMR 7164) - Service d’Astrophysique CEA/Saclay APC Conference High Energy Phenomena in the Galactic Center June 17, 2005

  2. The Galactic Centre : an exciting and growing field Exciting : • closest look we can have to a Super Massive Black Hole and its complex surroundings in the Universe - Potential link with more distant AGNs • potentially harboring dark matter, UHE cosmic-ray accelerator… Growing : New high quality high energy data : • X-rays [0.1–10 keV] Chandra & XMM–Newton 1999 -… • g-rays [0.02-10 MeV] Integral 2002 - • TeV g-rays [0.1–20 TeV] HESS 2003 - Multi Wavelength Campaigns with radio and NIR

  3. Chandra & XMM–Newton High throughput : detailed spectro-imaging up to 10 keV Angular resolution : resolving this complex region, and measuring the quiescent spectrum of SgrA*

  4. Sulphur K Fe K 6.7 keV 4-6 keV +0.5° Chandra and XMM–Newton Sensitivity : acces to short time variability Galactic Latitude X-ray flares from SgrA*, look for periodicity… Continuum subtracted line emission Radio VLA

  5. INTEGRAL Sensitivity and angular resolution : mapping this complex region 20-30 keV 30-40 keV 40-60 keV 60-85 keV • IBIS/ISGRI mosaics in different energy bands: spectrum 20-120 keV • Possible shift of the central source between Sgr A and 1E1743

  6. HESS H.E.S.S. Preliminary Sensitivity, angular resolution, large Field of View

  7. But questions still open… What makes the 6.4 keV line ? Nature of hot component ? Origin of the large scale 511 keV line ?

  8. But questions still open… Integral Integral Spectrum of SgrA* ? Are Ultra High Energy Cosmic Rays accelerated at the GC ? How many sources ?

  9. What can we count on for sure ? AUGER GC and AGASA/Sugar prime targets Completion in 2006 Unprecedented statistics expected Angular resol. 0.5–1° ? GC 15° Gamma-ray sources and UHECR connection AGASA excess map in the a posteriori energy band [1017.9 – 1018.3] eV

  10. What can we count on for sure ? Gamma-ray - Neutrinos connection ANTARES Completion in 2007 Max of signal expected @ ~ 10 TeV Very low bckgd for point sources Angular resol. @ 10 TeV ~ 0.2° Expected rate (HESS) very low 0.02 evt/year but surprises possible… Clear need for a km3 experiment in a longer term

  11. What can we count on for sure ? Anticoincidence SuperAGILE Si tracker Mini- Calorimetre AGILE gamma-ray telescope Small ASI mission - launch date early 2006 GRID : E-range : 30 MeV – 30 GeV FoV 2.5 sr Dq 36 arcmin @ 1 GeV Improve EGRET error box radius by a factor of 2

  12. What can we count on for sure ? The GLAST mission : launch mid 2007 GLAST/LAT EGRET E range : 0.02 -300 GeV 0.02-30 E resolution : 10 % 10 % Eff. Area : 8000 cm2 1500 Field of view > 2 sr 0.5 sr Ang. Resol. ~ 3o @ 100 MeV 5.8° ~ 0.15o > 10 GeV Sensitivity <6 x 10-9 cm-2 s-1 ~ 10-7 Source locat. 0.5 - 5 arcmin 5–30 Orders of magnitude improvement upon EGRET

  13. What can we count on for sure ? Upgrade : HESS II • Lower threshold to extend the energy-range in mono-telescope mode • Better sensitivity at high energies in stereo Atmospheric Cerenkov (stress on HESS but also MAGIC, VERITAS, CANGAROO) Reduce GC source position uncertainty now 4'' ± 10''stat ± 20''syst from Sgr A* (1 pc)

  14. What can we count on for sure ? Full spectral coverage in gamma-rays ! • Connection space-ground • Variability

  15. And in a longer term ? An absolute necessity : get the angular resolution and the sensitivity down by orders of magnitude above 10 keV

  16. 0.0° XMM-Newton GC Survey 0.3-9 keV (Belanger et al 2005, in prep.) (Decourchelle et al. 2003) 0.0° INTEGRAL GC Survey 20-40 keV Sgr A Sgr B2 0.0° 1.0° 359.0°

  17. The 10 keV sensitivity gap reason XMM–Newton INTEGRAL 0.1–10 keV : focusing optics Spatial resolution : 15 arcsec High signal to noise 15 keV–10 MeV : coded masks Spatial resolution : 12 arcmin Moderate signal to noise

  18. The necessary future : use focusing optics as in longer wavelengths Focusing using a grazing incidence nested shells Wolter I mirror • Long focal length for high reflectivity at high energy In hard X-rays : feasible on a large energy range by extension of the « usual » soft X–rays techniques Projects NuSTAR and SIMBOL-X

  19. The Simbol-X mission Basically : long focal length telescope, using grazing incidence X–ray optics, with mirror and detectors mounted on two different spacecraft in formation flying. Characteristics Energy range : 0.5–70 keV Resolution : < 130 eV @ 6 keV, 1 % @ 60 keV Angular resol. : < 30 arcsec (local. < 3 arcsec) Effective area : > 550 cm2 E < 35 keV 150 cm2 @ 50 keV Sensitivity : 5 10-8 ph/cm2/s/keV (E < 40 keV) (5 s, 100 ks, DE = E/2)

  20. Optics (nominal) Shell diameters : 290 to 600 mm Focal length : 30 m Angles : 0.07° to 0.142° Shell thickness : 0.12 to 0.30 mm Number of shells : 100 Total mass : 213 kg Dq : ~ 30’’ HEW FOV : ~ 6 arcmin 580 cm2 @ 30 keV • Direct heritage from XMM–Newton • Long focal length for high reflectivity at high energy • Nickel shells with single layer Pt coating, obtained by well proven electroforming replication method • Low mass obtained via a reduced thickness of shells

  21. Focal plane < 17 keV > 17 keV SDD CdZnTe SDD CdZnTe Anticoincidence (BGO) Optical filter (0.1 mm Al) Low energy detector (450 mm Silicium) High energy detector (2 mm Cd(Zn)Te) Requirements • Pixel size of ~ 500 mm (gives good oversampling of the 4.4 mm PSF) • Full diameter of focal plane : 6 cm • Fast response detectors for full anticoincidence scheme • Avoid constraining cooling • Low energy response down to 0.5 keV • Good spectral resolution for Iron line

  22. Sensitivity XMM SIMBOL-X INTEGRAL 1 arcmin diameter region, 1 Ms exposure, DE = E/2

  23. in 2012 with Simbol-X The central 2 degrees > 20 keV today INTEGRAL GC Survey 20-40 keV Sgr A Sgr B2 0.0° 1.0° 359.0°

  24. Testing accretion models with SIMBOL-X SIMBOL-X 3 s, 1 hour • Measurement of spectra for a large range of flare intensities •Access to the high energy range, discriminating models •Quiescent spectrum at ~ 40 keV Liu & Melia, 2002

  25. Galactic Centre Diffuse Emission (Decourchelle et al. 04)

  26. Galactic Centre seen by SIMBOL-X (A. Decourchelle & J. Ballet) Spectrum in a 1 arcmin2 region Exposure time = 84 ks Simulation > 10 keV, 10 x 10 arcmin2 Total exposure = 300 ks

  27. Simbol–X status • Consortium led by France with a strong Italian involvment, and a firm participation of Germany • Mission proposed early 2004 to CNES in response to a call for scientific missions using spacecrafts in formation flying • Selected by CNES for phase 0 assessment (4 missions kept) • Phase A start, autumn 2005 (2 missions kept) •Selection end 2006 (1 mission kept) • Launch date : 2012 - 2 years of science observations

  28. Conclusions The Galactic Centre an exciting and growing field, with a rich future ! A lot of important results to come in the next years, but will not solve all questions A deeper look possible early next decade with currently designed new generation of instruments

More Related