1 / 8

SIAMOIS: optical test bench BOSS (Banc Optique SiamoiS)

SIAMOIS: optical test bench BOSS (Banc Optique SiamoiS). Pernelle Bernardi Observatoire de Paris-Meudon, LESIA. The test bench objectives. Simulation of all the components, except the interferometer: Far field of the optical fiber Qualification of the optical fiber + connectors

lori
Download Presentation

SIAMOIS: optical test bench BOSS (Banc Optique SiamoiS)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SIAMOIS: optical test benchBOSS (Banc Optique SiamoiS) Pernelle Bernardi Observatoire de Paris-Meudon, LESIA SIAMOIS, kickoff meeting, Paris, 15-16 may, 2006

  2. The test bench objectives Simulation of all the components, except the interferometer: • Far field of the optical fiber • Qualification of the optical fiber + connectors • Definition of the mechanical interface of the 2 fibers • Imaging spectra on the camera • Testing acquisition softwares and data processing SIAMOIS, kickoff meeting, Paris, 15-16 may, 2006

  3. calibration channel Segmentary mirror 2 plane mirrors narrow bandpass filter optical fibers beamsplitter bandpass filter 400-560nm QTH source collimator Andor camera signal channel Diffraction grating focusing objective Design of the test bench SIAMOIS, kickoff meeting, Paris, 15-16 may, 2006

  4. F/4 F/5 27.6mm Size of the CoRoT CCD 37mm Size of the beam QTH source optical fiber band-pass filter (400-560nm) CCD on translation stages Far field of the fiber The far field of the optical fiber defines the size of the 5 zones of the steps mirror. Acquisition of the beam profile with a CCD. SIAMOIS, kickoff meeting, Paris, 15-16 may, 2006

  5. QTH source optical fiber Measurement of the far field uniformity band-pass filter (400-560nm) CCD on translation stages dewar QTH source optical fiber power meter Measurement of the variations of the fiber transmission band-pass filter (400-560nm) dewar Qualification of the optical fiber • Two qualifications at -80°C • Optical fiber only  optical tests during cooling • Optical fiber + connectors  optical tests before/after cooling • Purchase of several fibers: • Two manufacturers • Two different jackets: PVC and metal SIAMOIS, kickoff meeting, Paris, 15-16 may, 2006

  6. signal fiber calibration fiber 50µm 128 ± 20µm 65µm Mechanical interface of the fibers • Specification: distance of 128 µm between the two fiber cores (signal & calibration) at the collimator focus • Design of the mechanical interface of the 2 fibers: • Test of the robustness of this component • Evaluation of the constraints on the fibers SIAMOIS, kickoff meeting, Paris, 15-16 may, 2006

  7. Implementation of the camera • Model: iDus DU440 • Active pixels: 1024 x 255 • Pixel size: 26 x 26µm • Back illuminated, AR coated for optimal performance in the 350nm region • Full well capacity: 465 ke- (typical) • Read noise: 4 @ 33kHz • Typical minimum temperature: -70°C (air cooled) • Andor software (LabView) • Acquisition • Real-time data display • Shutter control • Data processing • 2 spectra • Calibration source SIAMOIS, kickoff meeting, Paris, 15-16 may, 2006

  8. Conclusion • State of the test bench today: (in Meudon labs, ex CoRoT CCD test bench) • Waiting for equipment…after many difficulties to order it! • Beginning of the tests scheduled for june 2006 • 2 students SIAMOIS, kickoff meeting, Paris, 15-16 may, 2006

More Related