130 likes | 175 Views
Informal document No . GRSG-91-7 (91st GRSG, 17-20 October 2006 agenda i tem 1.2.5.). Transmitted by the expert from Hungary. ROLLOVER ACCIDENT WITH EJECTION OF OCCUPANTS. Date: 15.12.2005 early morning, gloom Place: Pécsdevecser, south Hungary. Dr MATOLCSY Mátyás. GRSG, 91st session
E N D
Informal document No. GRSG-91-7 (91st GRSG, 17-20 October 2006 agenda item 1.2.5.) Transmitted by the expert from Hungary ROLLOVER ACCIDENT WITH EJECTION OF OCCUPANTS Date: 15.12.2005 early morning, gloom Place: Pécsdevecser, south Hungary Dr MATOLCSY Mátyás GRSG, 91st session Geneva, October, 2006
THE COACH Type: IKARUS C56 Class: local, intercity class II Mass: 16,5 tons Length/height: 12m/3m Age: 6 years old, good technical conditions Occupants: 15+1 on board Approved: according to R.66
THE ROAD A, B, C photos a bout the road I. II. III. photos about the slope
THE ROAD • Narrow hilly road • 5-10 cm fresh snow on it, it was snowing • Stone guard on roadside • The bus drove slightly upwards with a speed of 30-40 km/h • Sharp right curve (90o) Position „A” Position „B”Position „C”
THE SCENE OF THE ACCIDENT • The scene • Slope with an inclination 30-35o smalltrees, bushes on the slope • 5-10 cm snow on the slope • Soft ground, grass under the snow
THE SCENE OF THE ACCIDENT Position „II” Position „I” Position „III”
THE SCENE OF THE ACCIDENT Taken from position „II” Taken from position „B” (both)
THE SCENE OF THE ACCIDENT from Position „II”
THE ROLLOVER PROCESS • The bus drove on the narrow snowy road upwards, slight inclination • In a sharp right curve (90o) the bus slipped • Broke through the stone guard on the other side and the rollover started • It was a slow process, the driver cried „keep yourself!” • 2 ¼ rotation and finally it stopped on its left side (the passengers mentioned 2-3, 3, 3-4 rotations)
THE SUPERSTRUCTURE • No considerabledeformation on the superstructure • The survival space remained intact • Both windscreen and rear window were fallen out without breaking (installation with rubber profile) • On the left all: side windows were fallen out • On the right: two side windows were fallen out, 3 remained
CASUALTIES • Casualties: 8 serious injuries • 8 light injuries, but 7 of them were hospitalized • Ejected: 3 occupants (among them the driver) • the driver was ejected through the windscreen getting slight injury • The driver helped to the occupants to leave the bus trough the emergency escape hatches • One woman said the she was ejected in „the second round” slight injury) • Partially ejected:3 occupants • They were partially under the bus • They were ejected in the „second round” • They had very serious injuries • It took one hour for the firemen to escape these passengers
SOME CONCLUSIONS • The approved superstructure (R.66) was strong enough in a rollover accident having 2 ¼ rotation on a slope (9-10 m level difference) • The requirements in R.66 are good enough – for traditional, large buses – to protect the occupants in protectable rollover accidents (PRA) • If the superstructure is strong enough, the ejection of the occupants is the most severe danger. • Both total and partial ejections could be dangerous