OVERFILL PREVENTION DEVICE

OVERFILL PREVENTION DEVICE. Mechanism. The OPD is compatible with all tanks equipped with manhole plates. 1. A. Where to place it ?. 1. The OPD has to be set on the filling pipe inside the tank. 2. 1. Manhole plate. 1. 1. 2. 3. 4. THE FLOAT. B. Technical characteristics. 1.

ltitus
Download Presentation

OVERFILL PREVENTION DEVICE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. OVERFILL PREVENTION DEVICE Mechanism

  2. The OPD is compatible with all tanks equipped with manhole plates . 1 A. Where to place it ? 1 The OPD has to be set on the filling pipe inside the tank. 2 1 Manhole plate 1 1 2

  3. 3 4 THE FLOAT B. Technical characteristics 1 THE BALANCE WEIGHT 2 1 THE VALVE 3 2 THE BALANCE SHAFT 4 THE PISTON 5 6 5 THE CHAMBER 6 Red area = crossing liquid area

  4. The 4 steps of the OPD mechanism: • THE FILLING STAGE • THE CLOSURE (level N1) • THE EMPTYING OF THE FLEXIBLE AND THE PIPE • 4) THE CLOSURE (level Nmax) C. Mechanism Manhole plates Valve Nmax level Balance Weight N1 level Float Low position Balance shaft n°1 Balance shaft n°2

  5. C. Mechanism 1) THE FILLING STAGE The float is in low position and the piston in the high position. The liquid flows through the OPD body (red area). The float gradually rises according to the tank filling level.

  6. C. Mechanism 2) THE CLOSURE (level N1) The balance Weights are carried along by the rise of the balance shaft on the float. The piston partially obstructs the flow which enables the increase of the hydraulic pressure in the chamber.

  7. C. Mechanism 2) THE CLOSURE (level N1) The hydraulic pressure let the Balance weights breaking away from the balance shaft. They finish their rise independently to the float while the piston sits on its seat. The N1 level is reached and ensures a full closure.

  8. C. Mechanism 3) THE EMPTYING OF THE FLEXIBLE AND THE PIPE The different steps of the emptying. • Closing the tanker truck valve. • Elimination of the hydraulic pressure in the chamber thanks to the flight hole pierced on the wrapping of the piston chamber and thanks to the opening valve. • Reopening of the piston • Emptying of the flexible (minimum 150 litters)

  9. C. Mechanism 4) LEVEL Nmax In the event of accidental decanting, repeated emptying operations or failure to comply with the flows stipulated by current standards, the overfill prevention device can reach a maximum level Nmax which prevents any further filling until the liquid level has fallen in the tank.

  10. D. Technical characteristicsHYDROCARBON OPD

  11. All our OPD are certified ATEX (protection II Gc IIB T6), are complied with the 94/9/CE directive and with the European norm EN 13616. E. Conformity

  12. I am at your disposal for any further information. Charles BROCHET +33 (0)1 60 05 18 58 Export@selfclimat.com