RinNOVA RinNOVA IN Inovia CIRCUITO GAS CAMERA STAGNA / APERTA

RinNOVA RinNOVA IN Inovia CIRCUITO GAS CAMERA STAGNA / APERTA. VALVOLA GAS MOD. SGV 100 B&P. COMPITO APRIRE E CHIUDERE IL GAS AL BRUCIATORE REGOLARE IL FLUSSO DEL GAS AL BRUCIATORE INTERROMPERE L’AFFLUSSO DEL GAS AL BRUCIATORE IN CASO DI INTERVENTO DELLE SICUREZZE CARATTERISTICHE

lynton
Download Presentation

RinNOVA RinNOVA IN Inovia CIRCUITO GAS CAMERA STAGNA / APERTA

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RinNOVA RinNOVA INInoviaCIRCUITO GASCAMERA STAGNA / APERTA

  2. VALVOLA GAS MOD. SGV 100 B&P • COMPITO • APRIRE E CHIUDERE IL GAS AL BRUCIATORE • REGOLARE IL FLUSSO DEL GAS AL BRUCIATORE • INTERROMPERE L’AFFLUSSO DEL GAS AL BRUCIATORE IN CASO DI INTERVENTO DELLE SICUREZZE • CARATTERISTICHE • DIMENSIONI COMPATTE • PRIVA DI ORGANI MECCANICI DI TARATURA; • A BASSA RUMOROSITA’ • MODELLO SGV 100 B&P • MODULATORE DA 1 a 37 mbar • TEMPERATURA -15°/ + 60° • ALIMENTAZIONE DEGLI OPERATORI A 24 Vdc. • RESISTENZA EV1 DI 900 OHM • RESISTENZA EV2 DI 6500 OHM

  3. FUNZIONE SPAZZACAMINO • VERIFICA TARATURA VALVOLA GAS • PROCEDURA PER ATTIVARE LA FUNZIONE: • ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO CONTEMPORANEAMENTE I TASTI A + B + C FINO A FAR APPARIRE IL PARAMETRO “P01”; • PREMERE IL TASTO A FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO “P09”; • TRAMITE IL TASTO D IMPOSTARE IL VALORE RIFERITO ALLA POTENZA ALLA QUALE SI VUOL FAR FUNZIONARE LA CALDAIA (vedi tabella); • PREMERE IL TASTO C PER MEMORIZZARE IL VALORE IMPOSTATO E PROCEDERE ALLA VERIFICA. A D B E A D B E C C

  4. TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MASSIMA: • ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO CONTEMPORANEAMENTE I SEGUENTI TASTI: A + B + C PER 10 sec • FINO A FAR APPARIRE SUL DISPLAY LE LETTERE P01 ED IL VALORE DEL MEDESIMO PARAMETRO A D B E A D B E C C

  5. TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MASSIMA: • SCORRERE I PARAMETRI PREMENDO IL TASTOA FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO P09. A D B E A D B E C C

  6. TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MASSIMA: • VARIARE A 15IL VALORE DEL PARAMETRO P09 PREMENDO IL TASTO D • MEMORIZZARE IL VALORE 15 IMPOSTATO PREMENDO IL TASTO C A D B E A D B E C C

  7. TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MASSIMA: • SUL DISPLAY COMPARIRA’ S-H ALTERNATO AL VALORE ELETTRONICO DI POTENZA MASSIMA; • VARIARE IL VALORE DEL PARAMETRO AGENDO SUL TASTO A • VERIFICARE IL VALORE TARATO TRAMITE UN MANOMETRO DIGITALE • SE VIENE SUPERATO IL VALORE DA IMPOSTARE SUL MANOMETRO E’ NECESSARIO USCIRE DALLA PROGRAMMAZIONE E RIPETERE LA PROCEDURA 1 A D B E A D B E C

  8. TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MASSIMA: • CONFRONTARE LA TARATURA IMPOSTATA CON I VALORI RIPORTATI SUL LIBRETTO CALDAIA. • RICORDARSI DI MANTENERE L’ANDAMENTO DI TARATURA IN SALITA; • MEMORIZZARE LA TARATURA TENENDO PREMUTO IL TASTO E FINO A CHE IL VALORE NON RIMANE FISSO. A D B E A D E B C

  9. TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MINIMA: • PER PASSARE ALLA TARATURA MINIMA PREMERE IL TASTO D • NEL DISPLAY COMPARIRA’ LA SCRITTA S-L (taratura minima) ALTERNATO AL VALORE ELETTRONICO DI POTENZA MINIMA A D B E A D E B C C

  10. TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MINIMA: • VARIARE IL VALORE DI TARATURA AGENDO SUL TASTO B • VERIFICARE IL VALORE TARATO TRAMITE UN MANOMETRO DIGITALE • SE VIENE SUPERATO IL VALORE DA IMPOSTARE SUL MANOMETRO E’ NECESSARIO USCIRE DALLA PROGRAMMAZIONE E RIPETERE LA PROCEDURA 1 A D B E A D E B C C

  11. TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MINIMA: • CONFRONTARE LA TARATURA IMPOSTATA CON I VALORI RIPORTATI SUL LIBRETTO CALDAIA. • RICORDARSI DI MANTENERE L’ANDAMENTO DI TARATURA IN DISCESA; • MEMORIZZARE LA TARATURA PREMENDO IL TASTO E FINO A CHE IL VALORE NON RIMANE FISSO. • TOGLIERE ALIMENTAZIONE ELETTRICA PER USCIRE DALLA PROGRAMMAZIONE A D B E A D E B C C

  12. TARATURE GAS • VALORI TARATURA GAS :

  13. CAMBIO GAS • PROCEDURA CAMBIO GAS (1) • SOSTITUIRE GLI UGGELLI AL BRUCIATORE; • CONFIGURARE LA SCHEDA PER IL TIPO DI GAS UTILIZZATO. • ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMERE CONTEMPORANEAMENTE I SEGUENTI TASTI: • 12, 13 e 14, PER 10 sec; PER IL MODELLO RinNOVA; • 13, 16 e 17, PER 10 sec; PER IL MODELLO INOVIA; • FINO A FAR APPARIRE SUL DISPLAY LE LETTERE P01 ED IL VALORE DEL MEDESIMO PARAMETRO INOVIA RinNOVA

  14. CAMBIO GAS • PROCEDURA CAMBIO GAS (2) • SCORRERE I PARAMETRI PREMENDO IL TASTO: • 14, PER IL MODELLO RinNOVA; • 17, PER IL MODELLO INOVIA; • FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO P05. INOVIA RinNOVA

  15. CAMBIO GAS • PROCEDURA CAMBIO GAS (3) • MODIFICARE IL VALORE DEL PARAMETRO P05 TRAMITE IL TASTO: • 14, PER IL MODELLO RinNOVA; • 17, PER IL MODELLO INOVIA; • FINO A FAR APPARIRE IL VALORE IN FUNZIONE AL TIPO DI GAS SEGUENDO LA TABELLA SOTTO RIPORTATA: • MEMORIZZARE IL VALORE PREMENDO IL TASTO: • 12, PER IL MODELLO RinNOVA; • 13, PER IL MODELLO INOVIA

  16. UGELLI - ELETTRODI COLLETTORE GAS CON UGELLI • DATI BRUCIATORE • 24CM N° 11 RAMPE • 24BM N° 13 RAMPE • 28CM N° 14 RAMPE • 28BM N° 15 RAMPE • 32CM N° 16 RAMPE • UGELLI METANO • 24CM = n° 11 X 1,30 • 24BM = n° 13 X 1,25 • 28CM = n° 14 X 1,30 • 28BM = n° 15 X 1,20 • 32CM = n° 16 x 1,30 • UGELLI GPL • 24CM= 11 X 0,78 • 24BM= 13 X 0,75 • 28CM= 14 X 0,77 • 28 BM=15X0,75 • 32CM= 16 X 0,77 ELETTRODO DI ACCENSIONE E RILEVAZIONE • COMPITO • ELETTRODO DI ACCENSIONE E RILEVAZIONE : INNESCARE LA FIAMMA SULLA MISCELA ARIA GAS ED INVIARE IL SEGNALE DI IONIZZAZIONE ALLA SCHEDA DI ACCENSIONE • CARATTERISTICHE • CORPO IN CERAMICA • ELETTRODO IN KANTAL • POSIZIONATO CENTRALMENTE AL BRUCIATORE • SCARICA ESEGUITA TRA ELETTRODO E BRUCIATORE

  17. VENTILATORE - VENTURI • COMPITO • EVACUARE I PRODOTTI DELLA COMBUSTIONE • DATI DEL MODELLO 24 KW • MODELLO LN NATALINI • ALIMENTAZIONE 220 VC.A. • POTENZA: • 24 KW = 33 W / 63 OHM • 28 KW = 47 W / 46 OHM • 32 KW = 60 W / 25 OHM VENTURI • COMPITO • CONTROLLARE LA VELOCITA’ DEI FUMI • CREARE UN SEGNALE DI DEPRESSIONE • CARATTERISTICHE • REALIZZATO IN MATERIALE PLASTICO (RAYTON) • RESISTENTE A OLTRE 200°C

  18. PRESSOSTATO FUMI • COMPITO • VERIFICA I SEGNALI TRASMESSI DAL VENTURI • TRADUCE IN SEGNALE ELETTRICO LA DEPRESSIONE CREATA DAL VENTURI • CONSENTE L’ACCENSIONE DEL BRUCIATORE QUANDO C’E’ UNA CORRETTA DEPRESSIONE • NON CONSENTE L’ACCENSIONE IN ASSENZA O CON MINIMA DEPRESSIONE • IN CASO DI ANOMALIA: E05 DISPLAY • CARATTERISTICHE • MODELLO HUBA CONTROLL CIRCUITO CONTROLLO FUMI

  19. CAPPA FUMI E TERMOSTATO FUMI CAPPA FUMI (SOLO RINNOVA) • COMPITO • CONVOGLIA I FUMI NELLA CANNA FUMARIA • CARATTERISTICHE • DIAMETRO DI 130 mm TERMOSTATO FUMI (SOLO RINNOVA) • COMPITO • SPEGNERE IL BRUCIATORE IN CASO DI SCARSO TIRAGGIO CANNA FUMARIA • CARATTERISTICHE • CONTATTO NORMALMENTE CHIUSO: SE VIENE SUPERATA LA TEMPERATURA DI INTERVENTO IL CONTATTO SI APRE (65° C ) • TERMOSTATO A RIARMO AUTOMATICO • INDICAZIONE DISPLAY: E05 • RIARMO CALDAIA DA PULSANTE DI SBLOCCO.

  20. SISTEMA G.A.R.C. (SOLO INOVIA) • CARATTERISTICHE • IL SISTEMA GARC E’ COMPOSTO DAI SEGUENTI COMPONENTI: • SCHEDA ELETTRONICA; • ELETTRODO DI ACCENSIONE/RILEVAZIONE • BASA IL SUO FUNZIONAMENTO SUL SEGNALE DI RETROAZIONE (CORRENTE DI IONIZZAZIONE) PROVENIENETE DALL’ELETTRODO DI ACCENSIONE. TALE SEGNALE COMUNICA ALLA SCHEDA SE LA COMBUSTIONE E’ CORRETTA O MENO. • IN CASO DI COMBUSTIONE NON CORRETTA, LA SCHEDA ESEGUE DEI CONTROLLI, E IN BASE ALL’ANOMALIA RISCONTRATA, EVIDENZIA I SEGUENTI ERRORI: • BLOCCO PER ANOMALIA COMBUSTIONE IN FUNZIONAMENTO;