200 likes | 383 Views
RinNOVA RinNOVA IN Inovia CIRCUITO GAS CAMERA STAGNA / APERTA. VALVOLA GAS MOD. SGV 100 B&P. COMPITO APRIRE E CHIUDERE IL GAS AL BRUCIATORE REGOLARE IL FLUSSO DEL GAS AL BRUCIATORE INTERROMPERE L’AFFLUSSO DEL GAS AL BRUCIATORE IN CASO DI INTERVENTO DELLE SICUREZZE CARATTERISTICHE
E N D
VALVOLA GAS MOD. SGV 100 B&P • COMPITO • APRIRE E CHIUDERE IL GAS AL BRUCIATORE • REGOLARE IL FLUSSO DEL GAS AL BRUCIATORE • INTERROMPERE L’AFFLUSSO DEL GAS AL BRUCIATORE IN CASO DI INTERVENTO DELLE SICUREZZE • CARATTERISTICHE • DIMENSIONI COMPATTE • PRIVA DI ORGANI MECCANICI DI TARATURA; • A BASSA RUMOROSITA’ • MODELLO SGV 100 B&P • MODULATORE DA 1 a 37 mbar • TEMPERATURA -15°/ + 60° • ALIMENTAZIONE DEGLI OPERATORI A 24 Vdc. • RESISTENZA EV1 DI 900 OHM • RESISTENZA EV2 DI 6500 OHM
FUNZIONE SPAZZACAMINO • VERIFICA TARATURA VALVOLA GAS • PROCEDURA PER ATTIVARE LA FUNZIONE: • ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO CONTEMPORANEAMENTE I TASTI A + B + C FINO A FAR APPARIRE IL PARAMETRO “P01”; • PREMERE IL TASTO A FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO “P09”; • TRAMITE IL TASTO D IMPOSTARE IL VALORE RIFERITO ALLA POTENZA ALLA QUALE SI VUOL FAR FUNZIONARE LA CALDAIA (vedi tabella); • PREMERE IL TASTO C PER MEMORIZZARE IL VALORE IMPOSTATO E PROCEDERE ALLA VERIFICA. A D B E A D B E C C
TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MASSIMA: • ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO CONTEMPORANEAMENTE I SEGUENTI TASTI: A + B + C PER 10 sec • FINO A FAR APPARIRE SUL DISPLAY LE LETTERE P01 ED IL VALORE DEL MEDESIMO PARAMETRO A D B E A D B E C C
TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MASSIMA: • SCORRERE I PARAMETRI PREMENDO IL TASTOA FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO P09. A D B E A D B E C C
TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MASSIMA: • VARIARE A 15IL VALORE DEL PARAMETRO P09 PREMENDO IL TASTO D • MEMORIZZARE IL VALORE 15 IMPOSTATO PREMENDO IL TASTO C A D B E A D B E C C
TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MASSIMA: • SUL DISPLAY COMPARIRA’ S-H ALTERNATO AL VALORE ELETTRONICO DI POTENZA MASSIMA; • VARIARE IL VALORE DEL PARAMETRO AGENDO SUL TASTO A • VERIFICARE IL VALORE TARATO TRAMITE UN MANOMETRO DIGITALE • SE VIENE SUPERATO IL VALORE DA IMPOSTARE SUL MANOMETRO E’ NECESSARIO USCIRE DALLA PROGRAMMAZIONE E RIPETERE LA PROCEDURA 1 A D B E A D B E C
TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MASSIMA: • CONFRONTARE LA TARATURA IMPOSTATA CON I VALORI RIPORTATI SUL LIBRETTO CALDAIA. • RICORDARSI DI MANTENERE L’ANDAMENTO DI TARATURA IN SALITA; • MEMORIZZARE LA TARATURA TENENDO PREMUTO IL TASTO E FINO A CHE IL VALORE NON RIMANE FISSO. A D B E A D E B C
TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MINIMA: • PER PASSARE ALLA TARATURA MINIMA PREMERE IL TASTO D • NEL DISPLAY COMPARIRA’ LA SCRITTA S-L (taratura minima) ALTERNATO AL VALORE ELETTRONICO DI POTENZA MINIMA A D B E A D E B C C
TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MINIMA: • VARIARE IL VALORE DI TARATURA AGENDO SUL TASTO B • VERIFICARE IL VALORE TARATO TRAMITE UN MANOMETRO DIGITALE • SE VIENE SUPERATO IL VALORE DA IMPOSTARE SUL MANOMETRO E’ NECESSARIO USCIRE DALLA PROGRAMMAZIONE E RIPETERE LA PROCEDURA 1 A D B E A D E B C C
TARATURE GAS • PROCEDURA TARATURA GAS • TARATURA PORTATA TERMICA MINIMA: • CONFRONTARE LA TARATURA IMPOSTATA CON I VALORI RIPORTATI SUL LIBRETTO CALDAIA. • RICORDARSI DI MANTENERE L’ANDAMENTO DI TARATURA IN DISCESA; • MEMORIZZARE LA TARATURA PREMENDO IL TASTO E FINO A CHE IL VALORE NON RIMANE FISSO. • TOGLIERE ALIMENTAZIONE ELETTRICA PER USCIRE DALLA PROGRAMMAZIONE A D B E A D E B C C
TARATURE GAS • VALORI TARATURA GAS :
CAMBIO GAS • PROCEDURA CAMBIO GAS (1) • SOSTITUIRE GLI UGGELLI AL BRUCIATORE; • CONFIGURARE LA SCHEDA PER IL TIPO DI GAS UTILIZZATO. • ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMERE CONTEMPORANEAMENTE I SEGUENTI TASTI: • 12, 13 e 14, PER 10 sec; PER IL MODELLO RinNOVA; • 13, 16 e 17, PER 10 sec; PER IL MODELLO INOVIA; • FINO A FAR APPARIRE SUL DISPLAY LE LETTERE P01 ED IL VALORE DEL MEDESIMO PARAMETRO INOVIA RinNOVA
CAMBIO GAS • PROCEDURA CAMBIO GAS (2) • SCORRERE I PARAMETRI PREMENDO IL TASTO: • 14, PER IL MODELLO RinNOVA; • 17, PER IL MODELLO INOVIA; • FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO P05. INOVIA RinNOVA
CAMBIO GAS • PROCEDURA CAMBIO GAS (3) • MODIFICARE IL VALORE DEL PARAMETRO P05 TRAMITE IL TASTO: • 14, PER IL MODELLO RinNOVA; • 17, PER IL MODELLO INOVIA; • FINO A FAR APPARIRE IL VALORE IN FUNZIONE AL TIPO DI GAS SEGUENDO LA TABELLA SOTTO RIPORTATA: • MEMORIZZARE IL VALORE PREMENDO IL TASTO: • 12, PER IL MODELLO RinNOVA; • 13, PER IL MODELLO INOVIA
UGELLI - ELETTRODI COLLETTORE GAS CON UGELLI • DATI BRUCIATORE • 24CM N° 11 RAMPE • 24BM N° 13 RAMPE • 28CM N° 14 RAMPE • 28BM N° 15 RAMPE • 32CM N° 16 RAMPE • UGELLI METANO • 24CM = n° 11 X 1,30 • 24BM = n° 13 X 1,25 • 28CM = n° 14 X 1,30 • 28BM = n° 15 X 1,20 • 32CM = n° 16 x 1,30 • UGELLI GPL • 24CM= 11 X 0,78 • 24BM= 13 X 0,75 • 28CM= 14 X 0,77 • 28 BM=15X0,75 • 32CM= 16 X 0,77 ELETTRODO DI ACCENSIONE E RILEVAZIONE • COMPITO • ELETTRODO DI ACCENSIONE E RILEVAZIONE : INNESCARE LA FIAMMA SULLA MISCELA ARIA GAS ED INVIARE IL SEGNALE DI IONIZZAZIONE ALLA SCHEDA DI ACCENSIONE • CARATTERISTICHE • CORPO IN CERAMICA • ELETTRODO IN KANTAL • POSIZIONATO CENTRALMENTE AL BRUCIATORE • SCARICA ESEGUITA TRA ELETTRODO E BRUCIATORE
VENTILATORE - VENTURI • COMPITO • EVACUARE I PRODOTTI DELLA COMBUSTIONE • DATI DEL MODELLO 24 KW • MODELLO LN NATALINI • ALIMENTAZIONE 220 VC.A. • POTENZA: • 24 KW = 33 W / 63 OHM • 28 KW = 47 W / 46 OHM • 32 KW = 60 W / 25 OHM VENTURI • COMPITO • CONTROLLARE LA VELOCITA’ DEI FUMI • CREARE UN SEGNALE DI DEPRESSIONE • CARATTERISTICHE • REALIZZATO IN MATERIALE PLASTICO (RAYTON) • RESISTENTE A OLTRE 200°C
PRESSOSTATO FUMI • COMPITO • VERIFICA I SEGNALI TRASMESSI DAL VENTURI • TRADUCE IN SEGNALE ELETTRICO LA DEPRESSIONE CREATA DAL VENTURI • CONSENTE L’ACCENSIONE DEL BRUCIATORE QUANDO C’E’ UNA CORRETTA DEPRESSIONE • NON CONSENTE L’ACCENSIONE IN ASSENZA O CON MINIMA DEPRESSIONE • IN CASO DI ANOMALIA: E05 DISPLAY • CARATTERISTICHE • MODELLO HUBA CONTROLL CIRCUITO CONTROLLO FUMI
CAPPA FUMI E TERMOSTATO FUMI CAPPA FUMI (SOLO RINNOVA) • COMPITO • CONVOGLIA I FUMI NELLA CANNA FUMARIA • CARATTERISTICHE • DIAMETRO DI 130 mm TERMOSTATO FUMI (SOLO RINNOVA) • COMPITO • SPEGNERE IL BRUCIATORE IN CASO DI SCARSO TIRAGGIO CANNA FUMARIA • CARATTERISTICHE • CONTATTO NORMALMENTE CHIUSO: SE VIENE SUPERATA LA TEMPERATURA DI INTERVENTO IL CONTATTO SI APRE (65° C ) • TERMOSTATO A RIARMO AUTOMATICO • INDICAZIONE DISPLAY: E05 • RIARMO CALDAIA DA PULSANTE DI SBLOCCO.
SISTEMA G.A.R.C. (SOLO INOVIA) • CARATTERISTICHE • IL SISTEMA GARC E’ COMPOSTO DAI SEGUENTI COMPONENTI: • SCHEDA ELETTRONICA; • ELETTRODO DI ACCENSIONE/RILEVAZIONE • BASA IL SUO FUNZIONAMENTO SUL SEGNALE DI RETROAZIONE (CORRENTE DI IONIZZAZIONE) PROVENIENETE DALL’ELETTRODO DI ACCENSIONE. TALE SEGNALE COMUNICA ALLA SCHEDA SE LA COMBUSTIONE E’ CORRETTA O MENO. • IN CASO DI COMBUSTIONE NON CORRETTA, LA SCHEDA ESEGUE DEI CONTROLLI, E IN BASE ALL’ANOMALIA RISCONTRATA, EVIDENZIA I SEGUENTI ERRORI: • BLOCCO PER ANOMALIA COMBUSTIONE IN FUNZIONAMENTO;