An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Optical Cavity R&D around KEK-ATF T.Takahashi Hiroshima Univ. Nov. 2008 LCWS08 at Chicago T.Takahashi Hiroshima

  2. an idea Klemiz, Monig

  3. Experimental R/D in ATF Hiroshima-Waseda-Kyoto-IHEP-KEK Make a fist prototype 2-mirror cavity Lcav= 420 mm . Put it in ATF ring

  4. accuracy ~ 0.8mm Set up at KEK-ATF Optical cavity electron beam Cavity position is moved Vertical Horizontal

  5. Feedback to Achieve 3 Conditions pulse stacking cavity Lcav = n  Lcav = m Llaser mode locked laser Laser freq = Ring RF

  6. Transmitted light The appearance of light resonance signal Mirror reflectivity : 99.6% Mode locked laser PD Transmitted light (Photo diode) 0.7nm ~l/enhacement/p the optical cavity is on resonant Reflected light time (ms) 1ms Continued to change the length of the external cavity.

  7. Cross-feedback=Closed loop (Sakaue) PID Piezo offset Laser PD laser light pulses sync. to Acc. keep resonance Phase Detector RingRF Piezo Stacking Cavity Ref-light

  8. 2-mirror-cav to 4-mirror-cav. 2-mirror cavity 4-mirror cavity e-beam laser beam Spot size = 30 um Enhance = 1000 R. Cizeron Spot size = 10 um Enhance = 10000 difficult to achieve both high enhancement and small spot

  9. 2D configuration α Focal points for horizontal and vertical are not same 3D configuration

  10. R&D of 4 mirrors cavity started

  11. Tworesonat peaks due to geometrical phase Right Linear Left

  12. Summary and prospects • photon generation by Laser pulse stacking cavity / accelerator has been demonstrated both for • Polarized electron source (PosiPol) • hard x ray generation (LUCX) • A project for x ray source has started • All projects going to 4 mirror ring cavity • Technique with Ring cavity and e-beam will be accumulated in next 3-4year • Specific study is for 100 m long cavity is necessary • supporting 1m scale mirrors • adaptive optics to maintain phase front • Feed back experiment to cavity design • 3 Dimensional cavity • polarization T.Takahashi Hiroshima

  13. Optical Cavity R&D around ATF • O(10MeV) gs for Compton Based Polarized Positron source. • Hard X ray (~30keV) sources • LUCX project • New 5 year project • Compact X ray source w/ SRF electron accelerator and pulse stacking cavity. Accumulating technique and experiences w/ cavity and accelerators. ring cavities are being planned as next step T.Takahashi Hiroshima

  14. data summary Stacked Laser power[W] bunch /train current [mA] normarized gs/A/W gs/crossing exectation Normalized g yield seems to decrease as # bunches/train goes up Bunch (size, timing) fluctuation in the ATF suspected