VSD Incentives and Applications

VSD Incentives and Applications. Amaan Laheri, KEMA. Agenda. Energy efficiency and Variable Speed Drives (VSD) New prescriptive VSD incentive application for : Chillers Fans Pumps Air Compressors Ineligible measures Q & A. Energy Efficiency and VSD.

malia
Download Presentation

VSD Incentives and Applications

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. VSD Incentives and Applications Amaan Laheri, KEMA

  2. Agenda • Energy efficiency and Variable Speed Drives (VSD) • New prescriptive VSD incentive application for : • Chillers • Fans • Pumps • Air Compressors • Ineligible measures • Q & A

  3. Energy Efficiency and VSD • How can a VSD improve energy efficiency? • How is the VSD controlled?

  4. Now Prescriptive – VSDs on: • Fan or pump motors, 200 HP or less: $60 per HP • Chillers, $25 per HP • Air compressors<100 HP, $100 per HP

  5. A Look at the New Application

  6. Up to 100 HP 101 HP to 200 HP Over 200 HP Custom Application

  7. VSDs on Fan, Pump or Air Compressor Motors Supply fan 1&2 SFA DD BI 5814 60 2 $60 $7,200 Return fan 1&2 RFA DD DP 5814 40 2 $60 $4,800 Chiller #7 ONF 8760 960 1 $25 $24,000 Air Compressor #3 ACP N/A TWS 581450 1 $100 $5,000 AHU SF#10 SFA IGV BI 8,760 125 1 $60 $7,500 $

  8. Motors Over 100 HP AHU SF-10 Labs, offices, classrooms Conditioned air in labs, offices, & classrooms B1 – air foil 125 92% AFC-124b Acme Fan Co. 4 in H2O 75,000 cfm Inlet guide vanes 3 in H2O

  9. 24/7 24/7 N/A N/A 0.89 54.6 128 277

  10. Varies 3 in H2O 57.8 876 35.2 3942 23.1 3942 55.0 876 50.6 3942 47.3 3942 8760 3760 Estimated

  11. Incentive Capping

  12. Specifications • Existing throttling devices such as inlet vanes, bypass dampers, and throttling valves must be permanently removed or disabled. • VSD must be installed with automatic control technology.

  13. Not Eligible for Incentives • VSDs installed on equipment that operates less than 1,200 hours per year • Replacements of existing VSDs • VSDs installed on redundant/backup motors • VSDs installed in place of multi-speed flow control equipment (such as two-speed cooling tower fans) • VSDs installed in place of variable pitch blade flow control equipment • VSDs installed for the purpose of “soft-starting” motors • VSDs installed on pumps where affinity laws are not in effect, such as positive displacement pumps

  14. Where to find the New Application www.ComEd.com/bizincentives

  15. ComEdSmartIdeas@KEMA.com Program questions (888) 806-2273 Fax: 1-630-480-3436 Outreach Team 630-480-3434 www.ComEd.com/bizincentives Program information Application forms Policy and Procedures Manual For More Information