An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Data Acquisition System for the TPC Sector Test Klaus Schossmaier CERN EP-AID ALICE TPC collaboration meeting GSI, Darmstadt, Germany 2-3 June 2003

  2. Setup in Hall 167 gas vessel readout chamber electronics data acquisition auxiliary systems: - gas - cooling - low voltage - high voltage TPC collaboration meeting, 2-3 June 2003

  3. Readout close-up Inner Readout Chamber (IROC) Front End Cards (FEC) Data Acquisition System (DAQ) Readout Control Unit (RCU) in a PC TPC collaboration meeting, 2-3 June 2003

  4. Present DAQ Front-end bus (GTL) Local slow control (serial) FEC 128 CH FEC 128 CH PCI board from PLDA custom-made mezzanine card RCU 1 FEC 128 CH PCI Ethernet PC FEC 128 CH LabView Online monitoring http://mactpc01.cern.ch/~tpc Cosmic trigger: 1 event in about 4 minutes Event size: 128*4*500*10 bits = 312 KB TPC collaboration meeting, 2-3 June 2003

  5. PC RORC DDL- DIU DDL-SIU detector electronics Detector Data Link (DDL) • The DDL will be installed between the detectors and the front-end computers. • The DDL is an integral part of the ALICE data acquisition system. • The DDL provides up to 200 MB/s bandwidth. • The DDL consists of three parts: • Destination Interface Unit (DIU):on the front-end computers  connected via the RORC (pRORC or HLT-RORC) • Multi-mode optical fiber cable:to bridge up to 200 meters, full duplex LC connector • Source Interface Unit (SIU):on the detector electronics  connected to the RCU (prototype 1, 2, 3) TPC collaboration meeting, 2-3 June 2003

  6. DDL hardware DDL-DIU with pRORC Fiber cable (5 meters) pcald09.cern.ch: • PII@300Mhz • 256 SDRAM • 2x 40 GB disk • Fast Ethernet • RH 7.3.2 DDL-SIU This system is ready for operation! TPC collaboration meeting, 2-3 June 2003

  7. Fiber cables FEC FEC 128 CH 128 CH FEC FEC 128 CH 128 CH DDL- DIU DDL- DIU DDL-SIU FEC FEC 128 CH 128 CH RORC RORC PCI PCI Eth. PC Linux DDL-SIU DATE v4.6 FeC2 MOOD Monitoring Archiving Web Access Planned DAQ with DDL RCU 3 RCU 3 TPC collaboration meeting, 2-3 June 2003

  8. Towards the final DAQ • More realistic setup with respect to installations at Test Beams or at Point 2: • Data stream over a long distance • Electronics can be controlled remotely • PC with LabView is not necessary • High bandwidth upstream and downstream • Scalable to more RCUs and FECs • Early integration of front-end electronics with theALICE data acquisition system • All components are ready • DAQ milestone #388 of ALICE TPC collaboration meeting, 2-3 June 2003

  9. DATE • The Data Acquisition and Test Environment is the software framework of the ALICE DAQ. • It runs on Linux platforms. • The latest release is V4.6  user’s guide available • Well tested (test beams, data challenges) • Services/Packages: • System configuration • Run Control • Readout for DDL • Event Building • Event Recording • Messaging system • Performance monitoring TPC collaboration meeting, 2-3 June 2003

  10. DDL+DATE Performance 10.0 µs 12.5 µs 16.7 µs 25.0 µs 50.0 µs TPC collaboration meeting, 2-3 June 2003

  11. PC RORC DDL- DIU DDL-SIU detector electronics FeC2 • The DDL is capable to Control and Configure the Front-end electronics  integration with the ECS • Protocols are defined for 4 basic transactions: • Sending commands (19 bits information) • Reading status (19 bits address, 19 bits reply) • Sending data blocks (19 bits address, file to send) • Reading data blocks (19 bits address, file to read) • Interpreter is implemented for executing scripts • Example of a FeC2 script: FeC2 define THRESHOLDS /local/thresholds.data write_block 0x600 THRESHOLDS read_and_check_block 0x600 THRESHOLDS stop_if_failed -1 write_command 0x1ff stop TPC collaboration meeting, 2-3 June 2003

  12. Data Quality Monitor MOOD Using data of TPC sector test z distance (no cluster finding) Total charge Event size distribution Time projections • ROOT based • Offline: files • Online: DATE TPC collaboration meeting, 2-3 June 2003

  13. Working steps • Installation of PCs with Linux and DATE: • 1 PC with 2 DDLs for Hall 167 • 1 PC with 1 DDL for the TPC lab • Integration DATE  DDL RCU in the TPC lab • Stable data stream with high performance • Control&configuration of the final RCU prototype via DDL and FeC2 • Integration of the full DAQ chain in Hall 167 • Installing the PC and the 2 DDLs • Configuration • Test runs • Production runs • Online Monitoring • Analysis TPC collaboration meeting, 2-3 June 2003

  14. Summary • A planned DAQ setup by using the DLL for the TPC sector test in Hall 167 has been presented. • Hardware/software components of the new DAQ : • Hardware: • DDL: SIU, DIU, fiber cables • RORC: pRORC, HLT-RORC • RCU: prototype 1, 2, 3 • PC: Linux, disks, networking • Software: • DATE: readout, recording, services • FeC2: control/configure the front-end electronics • MOOD: data quality monitoring • Online monitoring software can be reused • Let’s start the work! TPC collaboration meeting, 2-3 June 2003