1 / 3

T. Lefevre

BLM system for the PETS in 2004. 6 Beam Loss Monitors are installed and distributed along the PETS Tank The detectors are Aluminum Cathode Electron Multipliers. They have a fast time response (2ns) which allows to observe the time evolution of the beam losses.

melora
Download Presentation

T. Lefevre

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BLM system for the PETS in 2004 • 6 Beam Loss Monitors are installed and distributed along the PETS Tank • The detectors are Aluminum Cathode Electron Multipliers. They have a fast time response (2ns) which allows to observe the time evolution of the beam losses. • All the BLM’s are supplied in parallel • Every signal can be amplified in the tunnel using a 26/46dB 300MHz amplifier card. • The output signals are then sent to fast Analog to Digital converters Rack 095 8 channels digitizer VME module 12 bits acquisition @ 96 MHz 0-2kV, 100mA Power supply Gallery Tunnel e- T. Lefevre

  2. BLM / PETS Cables ACEM 6 ACEM 5 ACEM 4 ACEM 3 ACEM 2 ACEM 1 Beam PETS configuration – Sept 2004 x = horizontal, y = vertical, z = longitudinal : z = 0 at the entrance of the PETS tank ACEM 1 (n°6) : x = -15cm y = +18cm z = -11cm Cable 2903848A ACEM 2 (n°7) : x = -15cm y = +18cm z = +20cm Cable 2903849A ACEM 3 (n°1) : x = -15cm y = +18cm z = +72cm Cable 2903850A ACEM 4 (n°2) : x = -15cm y = +18cm z = +111cm Cable 2903851A ACEM 5 (n°4) : x = -15cm y = +18cm z = +158cm Cable 2903852A ACEM 6 (n°5) : x = -15cm y = +18cm z = +186cm Cable 2903853A HV power supply Cable 2903856A T. Lefevre

  3. Price estimate • PETS Beam Loss Monitoring system: 6 BLM units  28.1kCHF • Detectors : (6) 8.1kCHF • Cables : 4.7kCHF • Connectors : 1.3kCHF • Power supply : 3.5kCHF • Mechanical support : 2kCHF • ADC’s : 5.5kCHF • Divers : 3kCHF T. Lefevre

More Related