1 / 17

RF measurement of T18 after High power test

RF measurement of T18 after High power test. Jiaru Shi 27.07.2011. CERN built T18. Before high power testing. after high power testing. Faya Wang @ SLAC. Faya Wang @ SLAC. Before high power testing. After high power testing. Standing wave pattern  Reflection before last regular cell.

mendel
Download Presentation

RF measurement of T18 after High power test

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RF measurement of T18 after High power test Jiaru Shi 27.07.2011

  2. CERN built T18 Before high power testing after high power testing

  3. Faya Wang @ SLAC

  4. Faya Wang @ SLAC

  5. Before high power testing After high power testing

  6. Standing wave patternReflection before last regular cell

  7. Detuning of cells(difference of required tuning) Not sure for input matching cell

  8. Amplitude Measurement of T18-SLAC #1 Before and After High Power Test Juwen Wang @ SLAC 11421.7 MHz at 21.32°C, N2 Before high Power test 1350 hours 11421.87 MHz at 20.4°C, N2 After high power test

  9. Phase Measurement of T18-SLAC #1 Before and After High Power Test Juwen Wang @ SLAC 11421.87 MHz at 20.4°C, N2 After high power test 11421.7 MHz at 21.32°C, N2 ore high Power test

  10. Amplitude Measurement of TD18-SLAC Before and After High Power Test Juwen Wang @ SLAC 11424.5 MHz at 21.46°C, N2 Before high Power test 11424.56 MHz at 21.1°C, N2 After high power test

  11. Phase Measurement of TD18-SLAC Before and After High Power Test Juwen Wang @ SLAC 11424.56 MHz at 21.1°C, N2 After high power test 11424.5 MHz at 21.46°C, N2 ore high Power test 16.5° Select bead pulling frequencies based on the same measurement condition for both before and after high power test

  12. Amplitude Measurement of T18-SLAC #1 Before and After High Power Test Juwen Wang @ SLAC T24 11424.1 MHz at 20.02°C, N2 Before high Power test 11424.15 MHz at 20.4°C, N2 After high power test

  13. Phase Measurement of T24-SLAC Before and After 800 Hours High Power Test Juwen Wang @ SLAC 11424.1 MHz at 21.2°C, N2 Before high power test 11424.1 MHz at 21.1°C, N2 After high Power test 6º Select bead pulling frequencies based on the measurement condition to get 2π/3 phase advance for both before and after high power test

  14. TD18 Chamfer100 um  -1MHz Chamfer TD18

  15. T18 chamfer100 um  -0.5MHz

  16. TD18 Iris ellipse aspect ratio 1.1to 1.2frequency + 8.2MHz aspect ratio +1MHz ~ removing 0.12mm3 copper at the iris