450 likes | 517 Views
Low Voltage Products & Systems Automation Technology. MaxSG Low Voltage Switchgear. Product overview Key features and benefits Construction Instrumentation Applications ABB Competitive Aspects MaxSG Projects Documentation. ATAP LVP&S. Low Voltage Switchgear. ATAP LVP&S.
E N D
Low Voltage Products & Systems Automation Technology MaxSGLow Voltage Switchgear
Product overview Key features and benefits Construction Instrumentation Applications ABB Competitive Aspects MaxSG Projects Documentation ATAP LVP&S Low Voltage Switchgear
ATAP LVP&S • Product overview • Key features and benefits • Construction • Instrumentation • Applications • ABB Competitive Aspects • MaxSG Projects • Documentation
ATAP LVP&S Product overview • Standards • SWITCHGEAR • ANSI C37.20.1 -Metal Enclosed LV Power Circuit Breaker Switchgear • ANSI C37.51 -Testing of Metal Enclosed LV AC Power Circuit Breaker Switchgear • UL 1558 -Switchgear Assemblies • CSA -Canadian Standard Assemblies • CIRCUIT BREAKER • ANSI C37.13 – LV AC Power Circuit Breakers Used in Equipment • ANSI C37.16 – Preferred Rating, Related Requirement, Application Recommendations For LV Power Circuit Breakers and AC Power Circuit Protectors • ANSI C37.50 – Testing of Low Voltage AC Power Circuit Breakers • UL 1066 – Low Voltage Power Circuit Breakers
Product overview ATAP LVP&S Product overview • UL 1558 • 600 VAC • 50/60Hz • 4000 Amps • 65 kA to 100 kA Symmetrical Short Circuit Rating • Indoor • Outdoor 3R– Non walk-in & Walk-in • IBC 2006 (pending) • Mimic bus • Communication
ATAP LVP&S • Product overview • Key features and benefits • Construction • Instrumentation • Applications • ABB Competitive Aspects • MaxSG Projects • Documentation
ATAP LVP&S Key features and benefits Three Main Configurations 2000A – 4000A
ATAP LVP&S Key features and benefits 4 Section Widths E4 3200 Amp E2/E3 800 – 1600 E2 800 - 1600A E6 4000 Amp E3 2500 Amp (65 & 100 kA) (65 kA) 40” 32” 24” 20”
ATAP LVP&S Key features and benefits NEMA 1A (Gasket) NEMA 3R
ATAP LVP&S Key features and benefits Emax Power Circuit Breakers – Best of the Breed • Trademark, size of CB • Trip unit • PB for manual opening • PB for manual closing • Lever to manually charge • closing spring • Label with electrical • characteristics • Mechanical device to signal • CB open “O” and Closed “I” • Signal for springs charged • or discharged • Mechanical indication of trip • Key lock in open position • Key lock and padlock in • racking-in, racking-out position • 12. Racking-in, racking-out device • Terminal box • Sliding contacts • CB position indicator
ATAP LVP&S Key features and benefits Three Trip Units • PR121 • Protection Features Only • PR122 • Protection Features • LCD Display • Current Measurement • Contact Wear • Communications option • PR123 • PR122 Features • Harmonic Measurements • Communications option
ATAP LVP&S Key features and benefits Safety Features Safety shutters (standard)
ATAP LVP&S Key features and benefits • Safety Features Breaker compartment keyed cells
ATAP LVP&S Key features and benefits • Safety Features • Padlocking provisions • Anti-insertion lock • Disconnect, connect, and test position
ATAP LVP&S • Product overview • Key features and benefits • Construction • Instrumentation • Applications • ABB Competitive Aspects • MaxSG Projects • Documentation
Structure Depth: 59.1” (Standard), 68.9” (Optional) Widths: 39.4”, 31.5”, 23.6”, 19.7” Height: 90” ATAP LVP&S Construction
Doors: Front doors - Semi-concealed hinges Rear doors – Bolted, optional hinge, Pad-locking handles available Infrared Windows (Optional) Paint ANSI 61 Electro static powder coat (standard) Other painting (Optional) ATAP LVP&S Construction
Rear cable area Mechanical Lugs (standard) Compression Lugs (optional) Main Bus Barriers separating bus compartment from cable compartment (Standard) Vertical Steel Barriers between sections in cable compartments (Optional) ATAP LVP&S Construction
Bus Design Standard temperature rise Max 65ºC over 40ºC ambient Platting Silver platted (standard) Tin platted (optional) Insulation Bare (standard) Insulated bus (optional) Bus bracing using steel supported polyester type fingerplates ATAP LVP&S Construction
ATAP LVP&S Construction Riser Bus Main Bus Runbacks
ATAP LVP&S Construction • Control Wiring • Inter-cubical wiring made easy • Terminal strips • Located in wire way on top of enclosure
ATAP LVP&S Construction Front door grounding Inter-cubicle wiring made easy
ATAP LVP&S • Product overview • Key features and benefits • Construction • Instrumentation • Applications • ABB Competitive Aspects • MaxSG Projects • Documentation
Breaker door mounted lights, meters and control ABB Indicating Lights Volt, amp, and watt meters Electoswitch Series 20 and 24 control switch Multifunction Metering Electro Industries Satec Others (optional for additional price adders) Relays ABB (provided standard when required) GE Multilin (Optional) Basler, Schweitzer, Others (Optional) Surge Protectors ABB TVSS (Standard) Others (Optional) ATAP LVP&S Instrumentation
ATAP LVP&S Instrumentation • High Resistance Ground System • Post Glover (Standard) • Others • I-Gard • Canadian standard
Software SD-View 2000, PC-based software system enables communication Send opening/closing commands to circuit-breakers Read electrical installation values (current, voltage, power factor, etc.) Read and modify trip characteristics of protection units Log of history of installation Status of apparatus Abnormal operating situation Current, voltage, power measurements in real time ATAP LVP&S Instrumentation
Software SD-Pocket Application designed to connect new protection releases to a PDA or PC Enables use of wireless communication to: Configure protection threshold function Monitor measurement functions Verify status of the circuit-breaker SD-Pocket application scenarios include: During start-up of switchgear, with rapid and error-free transfer of the protection parameters to the releases (also using the dedicated exchange file directly from Docwin); During normal installation service, gathering information on the circuit-breaker and load conditions (last trip information, runtime currents, and other information) ATAP LVP&S Instrumentation
Testing and Calibration PR010/T Portable Test Unit ATAP LVP&S Instrumentation • Testing and Calibration • ABB FT-1 Test Switch
ATAP LVP&S • Product overview • Key features and benefits • Construction • Instrumentation • Applications • ABB Competitive Aspects • MaxSG Projects • Documentation
Applications Markets where MaxSG exist Upstream of components Downstream of transformers BOP ATAP LVP&S Critical power Utilities Industrial facilities Oil and gas
Applications Main-Tie-Main Transfer Schemes Open Transition Close Transition Auto/Manual Transfers Kirk Key Interlock PLC Based Transfers Control box ATAP LVP&S
Applications ATAP LVP&S • Main-Tie-Main Transfer Schemes • DCS monitored
ATAP LVP&S • Product overview • Key features and benefits • Construction • Instrumentation • Applications • ABB Competitive Aspects • MaxSG Projects • Documentation
ATAP LVP&S ABB Competitive Aspects • ABB • Competitive Footprint • Stability and strong structure • Emax breaker • Trip Units PR121P, PR122P, and PR123P • Safety Feautures • Communication Capabilities (SCADA, Modbus, Ethernet, etc.) • Maintenance Switch Feature Available
ATAP LVP&S • Product overview • Key features and benefits • Construction • Instrumentation • Applications • ABB Competitive Aspects • MaxSG Projects • Documentation
Partial list of Customers, 2006, 2007, 2008 Utility/Power Plant Allegheny Ludlum Ameren LCRA Mirant Minn. Power Southern Company Topaz Zachry Wesco Whelan Energy Xcel Energy Oil, Gas, Energy Aramco Exxon Fluor- Tesoro Technip Shipyard Ingalls Mining Corletta Copper Inca Totten Food & Beverage ADM General Mills
ATAP LVP&S Canada MaxSG Projects • Technip PetroCanada • Inco Totten • St Clair • Kitimat • Drake Cement
ATAP LVP&S • Product overview • Key features and benefits • Construction • Instrumentation • Applications • ABB Competitive Aspects • MaxSG Projects • Documentation
Documentation Website www.abb.com Select Low Voltage Products and Systems; then Select Low Voltage Systems – NEMA; then Select LV Switchgear Available literature AC1801 (Brochures) LV059 (Technical manual Guide) Switchgear LV076 (Specification Guide) Switchgear ATAP LVP&S
ATAP LVP&S Question & Answers