CMS High Eta Detector - Feasibility Studies PROPOSAL BEAM TESTS 2010 AS 26.2.2010

CMS High Eta Detector - Feasibility Studies PROPOSAL BEAM TESTS 2010 AS 26.2.2010. PHASE I [Standard beam 1 week] Proto 1 (10x10 Standard) Time resolution as function of gas, induction field Proto 2 (10x10 Honeycomb) Gain uniformity, Efficiency

meris
Download Presentation

CMS High Eta Detector - Feasibility Studies PROPOSAL BEAM TESTS 2010 AS 26.2.2010

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CMS High Eta Detector - FeasibilityStudies PROPOSAL BEAM TESTS 2010 AS 26.2.2010 PHASE I [Standard beam 1 week] Proto 1 (10x10 Standard) Time resolution as function of gas, induction field Proto 2 (10x10 Honeycomb) Gain uniformity, Efficiency Proto 3 (10x10 Tech Etch) 1 week Gain Uniformity, Efficiency PHASE II [Standard Beam & Magnetic Field 1 week] Proto 1 (10x10 Standard) Space / Time resolution as function of incident angle and magneticfield Proto 3 (10x10 Tech Etch) Space Time resolution as function of incident angle and magnetic field Full SizeProto I Efficiency, Gain Uniformity PHASE III Use Proto 1,2,3 to play with r/o strip size Full Size Proto I Efficiency Gain Uniformity, Time Resolution, Gas optimization, Cluster Size, Noise, Electronics, Magnetic Field

  2. CMS High Eta Detector - FeasibilityStudies PROPOSAL LAB TESTS 2010 AS 26.2.2010 PHASE II June – July – August Proto 1 (10x10 Standard) Time resolution, efficiency, noise electronics, performance as function of gas mixture ? Proto 2 (10x10 Honeycomb) – Long term X-ray ? Proto 3 (10x10 Tech Etch) – Long term at GIF ? Large Proto I – General Characterization Simulations: HV divider, chamber, circuit simulation (AS, SC) PHASE I March – April – June Proto 1 (10x10 Standard) Time resolution, efficiency, noise electronics, performance as function of Ei, gas mixture (AS, AM) Proto 2 (10x10 Honeycomb) characterization, efficiency, noise electronics, performance as function of gas mixture (AS, AM, new collab) Proto 3 (10x10 Tech Etch) Time resolution, efficiency, noise electronics, performance as function of gas mixture (AS, new collab) Simulations: GAS FLOW with realistic detector components (AS,SC) HV divider, chamber, circuit simulation (AS, AM,SC) Beam test 2009 - data analysis (AS,MT, HT ) Prep for 2010 Large Proto I – Assembly and Construction (AS, AM) PHASE III Sep – Oct – Nov Proto 1 (10x10 Standard) Long term GIF ? Proto 2 (10x10 Honeycomb) - Lob term X-ray ? Proto 3 (10x10 Tech Etch) – Long term at GIF ? Large Proto I – Beam tests and analysis Simulations: GAS FLOW