310 likes | 437 Views
Engineered Products Make-Up Air for Heating and Cooling. MAKE-UP AIR. Why do we need make up air?. TYPICAL APPLICATIONS. EXHAUST AIR BUILDING PRESSURIZATION BUILDING VENTILATION. EXHAUST AIR. KITCHEN HOODS MANUFACTURING APPLICATIONS PAINT BOOTHS PROCESS AIR. BUILDING PRESSURIZATION.
E N D
Engineered Products Make-Up Air for Heating and Cooling
MAKE-UP AIR Why do we need make up air?
TYPICAL APPLICATIONS • EXHAUST AIR • BUILDING PRESSURIZATION • BUILDING VENTILATION
EXHAUST AIR • KITCHEN HOODS • MANUFACTURING APPLICATIONS • PAINT BOOTHS • PROCESS AIR
BUILDING PRESSURIZATION • CORRIDOR PRESSURIZATION • FIRE CONTROL • KEEPS ODORS IN APARTMENTS, ETC. • BUILDING PRESSURIZATION • REDUCES OUTSIDE AIR INFILTRATION
BUILDING VENTILATION • BUILDING VENTILATION • CONSTANT VOLUME • INTERMITTENT VOLUME
HOW CAN STERLING HELP?? • Sterling Offers a Complete Line of Outdoor and Indoor HVAC Equipment to Satisfy Your Make-Up Air Needs.
Outdoor UnitsUnit Types • Model “GR” Option “G”– Gravity Vented Outdoor • Model “GR” Option “P”– Power Vented Outdoor
Indoor UnitsUnit Types • Model “GG” – Power Vented Indoor
Indoor UnitsUnit Types • Model “GX” – Separated Combustion Indoor
Indoor/Outdoor UnitsUnit Types • Model “AH” Air Handler
Arrangements • Consists of Individual Pre-Engineered Modules Arranged to Address Your Individual Applications
Furnace Type • Trane GR Duct Furnaces are Available in Two Types. • Standard Temperature Rise (20°- 60°F) • High Temperature Rise (60°- 90°F) • GG/GX 30°- 80° Rise Only • Furnace Type Also Determines the Unit Access Side (Left or Right) Based on the Direction of Airflow Through the Unit.
Furnace Construction Material • Duct Furnace Heat Exchangers are Available in 3 Types of Steel • Stainless Steel Packages: Provides a Total Package Protection by Including 409 SS Burners and Flue Collector • Aluminized Steel • 409 Stainless Steel • 321 Stainless Steel
Gas Type • Natural Gas • Propane (LP) Gas • Natural Gas w/ 100% Lockout • Combine with a Model “GR” Power Vented Furnace for IRI Compliance
GAS CONTROL • A Full Range of Gas Controls, Including: • Single Stage • Two Stage • Electronic Modulation • Room Sensing • Duct Sensing (W/, W/O Rm. O/R) • Others, Including 4-20 mA & 0-10 VDC Controls and Multi-Furnace Staging
Coil Options • Factory Installed Coils • Direct Expansion (DX) • Chilled Water • Steam • Hot water • Draw Through Design Maximizes Coil Efficiencies • Full Size ASHRAE 62 Compliant Drain Pan • 4 Row & 6 Row, Single or Dual Circuit • Cooling Coil 1,000-6,300 CFM Range* • 3-30 Tons, But There is Flexibility. When in Doubt, Call!
Indoor/Outdoor UnitsUnit Types • “EV” Evaporative Cooler Section
Features and Benefits • Heating Capacities from 100 to 1,200 MBH • Air Flows from 800 to 14,000 CFM • 80% Efficient/Natural and Power Vented Duct Furnaces
Features and Benefits • 18 Gauge Cabinets Painted Trane Grey • 20 Gauge Aluminized Steel Heat Exchangers • Single Stage Redundant Gas Valve • Low internal static pressures allow for smaller motor break horse power requirements
Features and Benefits • Standard Left Hand Access, Right Hand Optional • Multiple Gas and Air Control Options • 1” Matte Face Insulation
Features and Benefits • Economizer Control • Door Safety Interlock
Features and Benefits • Ship Loose Parts List
Features and Benefits 1 2 8 3 9 4 10 5 11 6 12 13 7
Features and Benefits T - Status Lamps E - Airflow Proving Switch
Motor Types • Open Drip Proof (ODP) • Premium Efficiency (PEODP) • Totally Enclosed (TE) • Premium Efficiency (PETE)
Air Inlet Configuration • Indicates • Use of Outside and / or Return Air • Use of an Air Hood (Shipped Separately)
Air Control & Damper Arrangements • Twenty Air Control Options Available • Options Range From Simple Two-Position Dampers (Open & Closed) to Various Modulating Controls to ASHRAE Cycles I, II & III • Other Options Available Including Enthalpy Controlled Economizer, Pressure Sensing & CO2 Monitoring • Refer the Catalog For Full Descriptions of the Air Control and Damper Arrangements
Economizer Accessories • Enthalpy Control Outside Rain Hood • Enthalpy Control Inside Rain Hood
Low Leak Damper 409 SS Furnace Drip Pan High Altitude Derate Input Derate Evaporative Cooler 12” CELdek® Media 8” & 12“ GLASdek ® Media Clogged Filter Switch Manual Blower Switch Firestat (Supply and / or Return) Freezestat (Time Delayed) Ambient Lockout Interlock Relays (Specify Purpose) Moisture Eliminators Horizontal Return Status Lamps Double Wall Construction Service Convenience Package High / Low Gas Pressure Switch Filters (TA, WA & Pleated) Through the Base Utility Penetrations Factory Installed Options
High Pressure Regulators Time Clocks GFI Convenience Outlet Thermostats DuctStats Disconnect Switches Evaporative Cooler Fill & Drain Kit Freezestat Remote Control Panel Field Installed Accessories