1 / 5

PVx-Connect Solution

PVx-Connect Solution. Don't let wiring costs prevent you from upgrading a PROVOX 20series system to a DeltaV system. This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization. Provox 20series I/O > DeltaV. Using IOPs.

nantai
Download Presentation

PVx-Connect Solution

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PVx-Connect Solution Don't let wiring costs prevent you from upgrading a PROVOX 20series system to a DeltaV system This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.

  2. This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization. Provox 20series I/O > DeltaV Using IOPs • No existing Provox hardware (I/O File – I/O card – I/O panel – I/O cable) is kept • Existing Provox I/O panels are replaced by new IOPs which are electrically and mechanically fully compatible • Existing wiring is kept in place • Time for HW migration from an old toward a new I/O panel : about 30mn per panel I/O card and I/O panel to be removed

  3. This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization. Provox Highway to be removed Primary Provox Highway Secondary Provox Highway SR90 or SRx Controller to be removed SR90 or SRx Controller Power supply and Communication Cards to be removed I/O cards 20 series to be removed I/O cables to be removed I/O Termination panel I/O Termination panel I/O Termination panel Process I/Os stay in place in the existing cable trays I/O panels to be removed Provox 20series I/O > DeltaV Using IOPs CP6701 1 - 14 Process I/Os

  4. This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization. Primary DeltaV Highway Secondary DeltaV Highway The new DeltaV architecture is installed I/O3 I/O6 I/O7 I/O1 I/O5 I/O8 I/O2 I/O4 PS Cntrl The new I/O cables are installed between IOPs and DeltaV I/O cards The new IOPs are installed using the existing mechanical structure of the cabinets (30 mn per panel) New I/O panel New I/O panel New I/O panel Provox 20series I/O > DeltaV Using IOPs Process I/Os

  5. PVx-Connect Solution The End

More Related