Plans for Radiation Damage Studies for Si Diode Sensors Subject to 1 GRaD Doses

Plans for Radiation Damage Studies for Si Diode Sensors Subject to 1 GRaD Doses. SLAC Testbeam Workshop March 17 2011. The Issue: ILC BeamCal Radiation Exposure. ILC BeamCal: Covers between 5 and 40 miliradians Radiation doses up to 100 MRad per year

natane
Download Presentation

Plans for Radiation Damage Studies for Si Diode Sensors Subject to 1 GRaD Doses

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Plans for Radiation Damage Studies for Si Diode Sensors Subject to 1 GRaD Doses SLAC Testbeam Workshop March 17 2011

  2. The Issue: ILC BeamCal Radiation Exposure ILC BeamCal: Covers between 5 and 40 miliradians Radiation doses up to 100 MRad per year Radiation initiated by electromagnetic particles (most extant studies for hadron –induced) EM particles do little damage; might damage be come from small hadronic component of shower? 2

  3. Hadronic Processes in EM Showers • There seem to be three main processes for generating hadrons in EM showers (all induced by photons): • Nuclear (“giant dipole”) resonances • Resonance at 10-20 MeV (~Ecritical) • Photoproduction • Threshold seems to be about 200 MeV • Nuclear Compton scattering • Threshold at about 10 MeV;  resonance at 340 MeV •  These are largely isotropic; must have most of hadronic component develop near sample 3

  4. Proposal: JLAB Hall B Beam Dump (Plan to run 0.05 A through next May)  Total power in beam ~250W. Post-radiator and sample Pre-radiator Oops – too much background for Hall B! What about SLAC?

  5. Proposed split radiator configuration 5mm Tungsten “pre” 13mm Tungsten “post” Separated by 1m Fluence (particles per cm2) 1.0 2.0 3.0 5 Radius (cm)

  6. Rastering • Need uniform illumination over 0.25x0.75 cmregion (active area of SCIPP’s charge collection measurement apparatus). • Raster in 0.05cm steps over 0.6x1.5 cm, assuming fluence profile on prior slide (see next slide for result) Exposure rate: e.g. 1 GRad at 1 nA 13.6 GeV e-  ~ 60 Hours

  7. ISSUES/CONCERNS/FEATURES • Alignment and Rastoring • We’ll need to know the absolute beam location to 1mm or so • Will rastoring be available, or will we need to move samples around ourselves? It would be much easier for our design if the beam moved. • Radiomtery • We’ll need dosimetry at ~10% accuracy • Will we need to worry about activation (we plan to do our damage assessment back in Santa Cruz

  8. ISSUES/CONCERNS/FEATURES II • Long Running periods (~60 hours for 1 GRad) • Can we run parasitically? • What access can we have during parasitic running? • Infrastructure • Temperature control (thermal load from beam ~10W, plus need to avoid annealing), • Control systems, etc.

  9. Parameters required for Beam Tests To the presenter at the ESTB 2011 Workshop: please, fill in the table (at best) with the important parameters needed for your tests

  10. SUMMARY • ILC BeamCal demands materials hardened for unprecedented levels of electromagnetic-induced radiation • 10-year doses will approach 1 GRad. • Not clear if hadrons in EM shower will play significant role  need to explore this • At 1 nA, 1 GRad takes a long time (60 hours); multiply time ~10 samples  really long time • More beam current (?) • Start with 100 MRad studies (already interesting)

  11. Backup

  12. Shower Max Results Photons with E > 100 MeV per electron, x 100 Photons with E > 10 MeV per electron, x10 Photons per electron Electrons, per GeV incident energy 1.0 2.0 3.0 12  Photon production ~independent of incident energy!

  13. G.P. Summers et al., IEEE Trans Nucl Sci 40, 1372 (1993) NIELe- Energy 2x10-2 0.5 MeV 5x10-2 2 MeV 1x10-1 10 MeV 2x10-1 200 MeV Damage coefficients less for p-type for Ee- < ~1GeV (two groups); note critical energy in W is ~10 MeV But: Are electrons the entire picture? 13

  14. 5.5 GeV Shower Profile “Pre” “Post” e+e- (x10) All  Remember: nuclear component is from photons in 10-500 MeV range. Fluence (particles per cm2) E > 100 MeV (x20) E > 10 MeV (x2) 14 Radius (cm)

  15. Fluence (e- and e+ per cm2) per incident 5.5 GeV electron (5cm pre-radiator 13 cm post-radiator with 1m separation) Center of irradiated area ¼ of area to be measured ¼ of rastoring area (0.5mm steps)

  16. 5.5 GeV Electrons After 18mm Tungsten Block Not amenable for uniform illumination of detector. Instead: split 18mm W between “pre” and “post” radiator separated by large distance Caution:nuclear production is ~isotropic  must happen dominantly in “post” radiator! Boundary of 1cm detector Fluence (particles per cm2) 16 Radius (cm)

  17. NIEL (Non-Ionizing Energy Loss) • Conventional wisdom: Damage proportional to Non- Ionizing Energy Loss (NIEL) of traversing particle • NIEL can be calculated (e.g. G.P. Summers et al., IEEE Trans Nucl Sci 40, 1372 [1993]) • At EcTungsten ~ 10 MeV, NIEL is 80 times worse for protons than electrons and • NIEL scaling may break down (even less damage from electrons/positrons) • NIEL rises quickly with decreasing (proton) energy, and fragments would likely be low energy •  Might small hadronic fractions dominate damage? 17

  18. BeamCal Incident Energy Distribution 2 4 6 8 10 e+/e- ENERGY (GEV) 18

  19. Wrap-up Worth exploring Si sensors (n-type, Czochralski?) Need to be conscious of possible hadronic content of EM showers Energy of e- beam not critical, but intensity is; for one week run require Ebeam(GeV) x Ibeam(nA) > 50 SLAC: Summer-fall 2011 ESA test beam with Ebeam(GeV) x Ibeam(nA) 17 – is it feasible to wait for this? 19

  20. Rates (Current) and Energy • Basic Idea: • Direct electron beam of moderate energy on Tungsten radiator; insert silicon sensor at shower max • For Si, 1 GRad is about 3 x 1016/cm2, or about 5 mili-Coulomb/cm2 • Reasonably intense moderate-energy electron or photon beam necessary What energy…? 20