100 likes | 247 Views
Door seal test set-up concepts. Generic Door seal concepts for personnel access and feed-through applications in the CUORE Radon barrier / Clean room assembly. Final design details will be customized to accomodate specific door seal cross-sections. For Carlo Bucci LNGS
E N D
Door seal test set-up concepts Generic Door seal concepts for personnel access and feed-through applications in the CUORE Radon barrier / Clean room assembly. Final design details will be customized to accomodate specific door seal cross-sections For Carlo Bucci LNGS Paolo Gorla LNGS Richard Kadel LBNL Robin Lafever LBNL
Comments: At the moment, there seems to be no special need for N2 ports in any of the test boxes.If such a need arises, they should be easy to retrofit.Note newer smaller boxes. Some details have been changed from the original concept, based on discussions with Leo Tatananni at the LNGS machine shop. He suggests 5mm Stainless Steel for the box construction, with all joints TIG welded. I concur.Details shown are generic and I encourage using local suppliers where possible, and will gladly modify design details if necessary to accommodate off-the-shelf solutions.Final details will be designed around specific seal cross-sections, Yet to be selected.Next steps might be to forward these concepts to Ezio Previtali and the Milano(?) Group for comments about the feasibility and proceedure for doing a suite of tests to proof Radon resistance of selected configurations and materials. CUORE Door seal test set-up Pressure Seal configuration CLOSURE DETAIL CUORE Door seal test set-up Pressure Seal configuration CLOSURE DETAIL Robin Lafever LBNL
CUORE Door seal test set-up GENERIC BOX Material preferences All 10mm thick Aluminum -welded or Steel -welded or Acrylic (plexiglas) –solvent welded Robin Lafever LBNL
CUORE Door seal test set-up Top shown removed Test Gasket specimen DeStaCo Clamp 91140 Doubler plate to allow blind-tapped holes for mounting screws Robin Lafever LBNL
CUORE Door seal test set-up Top shown installed Robin Lafever LBNL
CUORE Door seal test set-up REDUCED VOLUME Material: 5mm thick SS All joints TIG Welded Robin Lafever LBNL
CUORE Door seal test set-up Pressure Seal configuration Robin Lafever LBNL
CUORE Door seal test set-up Pressure Seal configuration Material: 5mm thick SS All joints TIG Welded Robin Lafever LBNL
CUORE Door seal test set-up Pressure Seal configuration CLOSURE DETAIL Robin Lafever LBNL
CUORE Door seal test set-up CUORE Door seal test set-up Pressure Seal configuration CLOSURE DETAIL Robin Lafever LBNL