1 / 27

Background Measurement: December 2011

Background Measurement: December 2011. Spring Test. Thomas E. Videbaek Stony Brook University, RHIG. Thomas K Hemmick Stony Brook University, RHIG. Outline:. Reminder: HBD Principle. Goals. December experiment: Run conditions Data Scintillator Data Neutron rates

nolen
Download Presentation

Background Measurement: December 2011

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Background Measurement:December 2011 Spring Test Thomas E. Videbaek Stony Brook University, RHIG Thomas K Hemmick Stony Brook University, RHIG SoLID Collaboration Meeting 2/3/2012

  2. Outline: • Reminder: HBD Principle. • Goals. • December experiment: • Run conditions • Data • Scintillator Data • Neutron rates • GEM detector rates and spectra • March test plans: • Rings • Tracks • EMC • TOF • Offline software SoLID Collaboration Meeting 2/3/2012

  3. g HV primary ionization photo electron charged particle or photon HV primary ionization e- HBD Principle Reverse Bias (HBD) Forward Bias Mesh CsI layer Triple GEM Readout Pads Readout Pads • BRIGHT! ~20 photo-electrons in 50 cm of gas: • Principle source of photons at LOW WAVELENGTH! • dN/dl ~ 1/l2 • QE falls linearly as l increases. • Single electron gain ~104(a bit limited by the CsI). • You can see a blob…single p.e. difficult. • More GEMs = higher gain…BUT there is a cost in hadron blindness.

  4. Target Ed ~0.1 kV/cm Hadron Blindness:UV photons vs charged particles • At slightly negative Ed, photoelectron detection efficiency is preserved whereas charge collection is largely suppressed. • Charge collected from ~150μ layer above top GEM AND the gaps between GEMs. • With n GEMs, reverse bias suppresses hadron gain from Gn to Gn-1

  5. Three Birds with One Stone • EIC & sPHENIX: • Develop CsI technology to measure rings. • Mirror technology. • Precision position measurement via charge division. • REQUIRES HIGHER GAIN! • SoLID • Threshold detector using mirror. • Less sensitive to neutron and low-E gammas. • Test Program: • December: Background measurement. • Spring: RINGS! SoLID Collaboration Meeting 2/3/2012

  6. December Goals: • How fast does a scintillator fire in the Hall? • What are the rates of neutrons (fast & slow)? • How quickly does our GEM detector fire? • Will we be able to see single photoelectrons? • What stack size will provide best conditions for running in March? • What is the degradation of hadron blindness for large numbers of GEMs? • Triple, Quadruple, Quintuple stacks. SoLID Collaboration Meeting 2/3/2012

  7. Simpler “November” Apparatus?? “DECEMBER” • CsIGemstack in CF44 • Pad readout (~50 channels) • Are THICK (1/2” SS) walls an issue? • Is this viable?

  8. Experimental Setup • High purity recirculating gas • ~1 ppm H2O & O2 • CAMAC DAQ • LeCroy High Voltage • GEM detector • Divider box allows for 'on the fly' stack size changes • Neutron Counters • BF310B + n  7Li + 4He • Bare counter (slow) • Wax counter (slow & fast) • Scintillators SoLID Collaboration Meeting 2/3/2012

  9. DAQ – dead simple • PC in the Hall • Remote desktop allows: • HV via serial port. • CAMAC via USB • USB CAMAC controller. • NIM Trigger: OR from the scintillators, three of the GEM pads, and either of the neutron counters. • Digitized trigger signals to provide a mask for the data. SoLID Collaboration Meeting 2/3/2012

  10. Run conditions in Hall A • Average beam current held around 1 microA for most of our runs • Some were taken at 20nA or 100nA. • Collection rates much slower, usually. • Depending upon the tune of the beam (either on target, hitting target holder, calorimeter run, etc.) background rates varied dramatically. • Anywhere from 1Hz to 1kHz. SoLID Collaboration Meeting 2/3/2012

  11. Scintillator Data • When we first turned on our phototubes, we saw7 million triggers in less than a minute. • Upon viewing data, could not parse the file. • Turned HV off phototubes for the rest of the runs. SoLID Collaboration Meeting 2/3/2012

  12. Neutron Data: Beam on Target Rate from typical on target run: Wax • Bare Neutron Counter shows few, if any, counts while beam is on target. Some runs show rates of ~0.6 Hz. • Average rate for Fast and Slow neutrons ~34.75 Hz. • Ratio of rates ~58. • Counter sensitivity: 1.9 cps per thermal neutron/cm2/sec SoLID Collaboration Meeting 2/3/2012 Rate from typical on traget run: Bare

  13. Neutron Data: Beam Off-Target Rate from a calorimeter run: Wax • Rate for Fast and Slow neutrons ~1.6 kHz. • During the tuning or calorimeter runs, the rates increase, but the ratio should remain constant. • Ratio of rates is ~35 on average. • Implies Slow neutrons are produced more during off target (i.e. striking collimators etc…) conditions. SoLID Collaboration Meeting 2/3/2012

  14. Neutron Rates • Wanted a plot of neutron rate vs. beam current, unfortunately we had a low number of records for low beam current. • Also lot of off target data. • Rough fit:~0.11 Hz/nA or ~0.06 therm-n/cm2/sec SoLID Collaboration Meeting 2/3/2012

  15. GEM Detector: Hadron Blindness Legend: Blue = +40 V Teal = +20 V Pink = 0 V Green = -20 V Red = -40 V • As the stack has few GEMs, you are able to achieve a better hadron blindness. • This is because ionization can occur in the gap between the first and second GEM. • For fewer GEMs we were unable to get small signals above the hardware threshold.  SoLID Collaboration Meeting 2/3/2012

  16. GEM Detector: Presence of MIPs • When the difference is taken between the forward-most and reverse-most bias, one should see MIPs. • Best for fewer GEMs via the Gn-1 principle. • Normally we expect ~15 p.e. for 1.5mm of CF4. • Here tracks are inclined ~17o above horizontal. • 15/sin(17) ~ 50….SWEET! SoLID Collaboration Meeting 2/3/2012

  17. GEM Detector: Threshold Rate • Rates of the different stacks as a threshold of primary electrons falls off rapidly. • For 5 stacks, rate ~0.1 Hz/nA with 0.5 p.e. threshold… SoLID Collaboration Meeting 2/3/2012

  18. GEM Detector: Neighbors • Finally, we looked at the response of trigger pads only when a neighboring pad fired as well. • Idea is that Cherenkov blob would fall on multiple pads more often than electron clouds from hadron. • Analysis not finished, but rates cut DRAMATICALLY! SoLID Collaboration Meeting 2/3/2012

  19. Spring Test: Point at Target. • “Beam” consists of scattered electrons & pions. • Particles must be collimated. • Need to “point” detector at target. • Slide jack post back&forth via remote control. SoLID Collaboration Meeting 2/3/2012

  20. Small Table Layout • All aboard! • Quintuple GEMstack (can always “shrink”). • Need trackers to know each particle’s trajectory. • PbGl is used to identify electrons (enough???) • Bore site laser of initial alignment. • Coarse pads in case scintillators fire too fast. • MRCP—why not? (TOF PID!!!) SoLID Collaboration Meeting 2/3/2012

  21. Cherenkov Optics • Optics defined by GEM size (Rring < 5 cm). • Rad-length for SoLID perfect fit for optics! • Should see 20 p.e. or more. • NOTE: Not all rings will be fully contained. SoLID Collaboration Meeting 2/3/2012

  22. VUV Mirror Interference Maximum • Require mirror reflectance DEEP in the VUV. • Ordinary MgF2 cutoff l<140nm. • Overcoat thickness = thin film reflection max! • Test Beam: Acton Optics • Future: Make our own 8’ diameter vessel SoLID Collaboration Meeting 2/3/2012

  23. Pad Segmentation • RING images produce POSITION CORRELATION! • Ambiguity for Compass (Cartesian) Coordinates • SOLN: New pad plane • ¼ rings in four quadrants • STAR-style strip-pixels. Pad Plane Arrives Monday SoLID Collaboration Meeting 2/3/2012

  24. DAQ: SRS (w/ cheats!) • MUST get aux detectors into data stream. • SRS does not work & play well with others. • SBU pad plane sends 8 input channels of APV25 cards to LEMO connectors. • Choosing the resistors & capallows any signal to coupleinto datastream. • MRCP: Use a TAC • Desire custom LEMOAPV25 card(s) SoLID Collaboration Meeting 2/3/2012

  25. Pattern Recognition • Require ONLINE Tracking (to find target). • HuijunGe writing “light environment”. • Must run “out of box”. • No dependences except root. • FRODO (son of AVATAR): • Singleton factory for context independent access. • STL vectors of simple objects: • Strips; PadStrips; Blobs; Clusters; • ALL objects can be drawn to root canvas (EVT DISPLAY) • URGENT: NEED TO UNDERSTAND SRS FILE FORMAT! SoLID Collaboration Meeting 2/3/2012

  26. MINIMUM: 1 day running -Magnet off -Magnet orientation=0 Rates SoLID Collaboration Meeting 2/3/2012

  27. Summary • Success depends upon multiple factors: • Sufficient beam time & conditions. • Reliable & Homogeneous DAQ • Multi-institutional efforts: • SBU, U.Va, J-Lab, Temple, Duke. • Online pattern recognition & tracking • Also depends upon: • Clean gas, high QE cathode, high/stable gain, accurate alignment, phase of the moon. • Schedule: • Last critical part (mirrors) arrive ~March 1. • Kondo & Kiad SBU @ this time. • Delivery to hall  Ides of March SoLID Collaboration Meeting 2/3/2012

More Related