An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ELECTRICAL COMPONENTS CHAPTER 3

  2. Circuit Protection

  3. Circuit Protection (Page C52 ) • Types of Fused Protection How to pull them

  4. Fuses (Page C52) • Auto-fuse (blade type and Color coded) • Mini-fuse • Maxi-fuse A. TEST HOLES B. REMOVAL

  5. Maxi-fuses C52 • Combination blade / cartridge • Protects main circuits • Safer than fusible link • Cover fewer circuits than a fusible link • Often in Power Distribution box

  6. Ceramic and Glass C52 & L53 • Rated by current failure level • Three letter code for type and size • Glass style replaces ceramic • Caution in pulling

  7. Two reasons for blowing Where do they blow? Why?

  8. New Circuits ? • What size of fuse should I install? • Use Watts law. Watts divided by volts Page L53

  9. FUSIBLE LINKS • Lighter gauge wire than main conductor • Covered with special insulation • Protect Main circuits • Usually under hood

  10. C54-55 L53-54 Fusible Links Repair • Location • Circuits protected • Insulation • Visual checks • Installing a new link • 4 wire sizes smaller (4 numbers larger) • Soldering

  11. Circuit Breaker C56 & L55 • Why circuit breakers • Styles • Deterioration

  12. TESTING CIRCUIT PROTECTION DEVICES • Must inspect closely • Type of failure determines cause • Best to use DVOM • Do not overload circuit by installing to large of fuse or tin foil • Connections must be tight • Do not use un-fused jumper wire

  13. Electrical Components

  14. Switches OPERATION Page C58-60 TESTING Page L57-58 • Controls electrical current (N.O. or N.C.) • Single-pole, single throw (SPST) • Momentary Switch • Single-pole, double throw switch (SPDT) • Ganged Switch

  15. Relays OPERATION Page C60-61 • Electromagnetic Switches (Relays) • Two Circuits • Control Circuit • Load Circuit • Magnetic field operates contacts • Late model relays are universal

  16. TESTING RELAYS Lab 59-60 • Can use several methods to test • Must Check both circuits • Be careful using test light if relay is operated by computer • Can bench test if needed • Some relays have schematic on them • Must be correct resistance

  17. SOLENOIDS C61 • Electromagnetic device with a iron core • Does mechanical work • Core is moveable and does work • Can test with DVOM

  18. C62-64 L61 STEPPED RESISTORS • Usually used to control fan motor speeds • Resistance is changed by control of switch • Controls current to change speeds • Thermal fuse

  19. OPERATION C62-64 TESTING LAB 62 Variable Resisters • Rheostats • Two terminals • Higher current • Potentiometer • Three terminals • Lower current • Many uses for variable types C62-63 & L62

  20. The three types of circuit defects are: • Shorts • Grounds • Opens • poor connections C75-78 L64-71

  21. TESTING FOR CIRCUIT DEFECTS • DVOM IS BEST TO USE! • Must know circuit operation before can diagnose problem • Must know how to use equipment and which equipment to use. LAB PAGE 64 TO 71

  22. Now, did he say, “Amps, Volts or Ohms”?