1 / 55

Lateral Design

Lateral Design. Lateral Material/Types. Drip tape Thin wall drip line Heavy wall drip line Polypipe with punch emitters Polypipe with sprays. Typical Layouts. More layouts. SDI. Lateral installation. SDI burial depth. Tape orientation One tape or more per bed Holes upward

nydia
Download Presentation

Lateral Design

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Lateral Design

  2. Lateral Material/Types • Drip tape • Thin wall drip line • Heavy wall drip line • Polypipewith punch emitters • Polypipe with sprays

  3. Typical Layouts

  4. More layouts

  5. SDI

  6. Lateral installation

  7. SDI burial depth

  8. Tape orientation • One tape or more per bed • Holes upward • Tape thickness • Trend toward thicker • Tape materials • Stretch vs. breakage

  9. Lateral Line Design • Important lateral characteristics • Flow rate • Location and spacing of manifolds • Inlet pressure • Pressure difference

  10. Standard requires • Pipe sizes for mains, submains, and laterals shall maintain subunit (zone) emission uniformity (EU) within recommended limits • Systems shall be designed to provide discharge to any applicator in an irrigation subunit or zone operated simultaneously such that they will not exceed a total variation of 20 percent of the design discharge rate.

  11. Start with average lateral

  12. Design objective • Limit the pressure differential to maintain the desired EU and flow variation • What effects the pressure differential • Lateral length and diameter • Economics longer and smaller • Manifold location • slope

  13. Allowable pressure loss (subunit) This applies to both the lateral and subunit. Most of the friction loss occurs in the first 40% of the lateral or manifold Ranges from 2 to 3 but generally considered to be 2.5 DPs =allowable pressure loss for subunit Pa = average emitter pressure Pn = minimum emitter pressure

  14. Emission Uniformity

  15. EU is related to Friction loss

  16. Example Given: CV=0.03, 3 emitters per plant, qa = .43gph Pa=15 psi, EU=92, x=0.57 Find: qn, Pn, and P

  17. Solution

  18. Practice problem

  19. Flow rate Where: l = Length of lateral, ft. (m). Se = spacing of emitters on the lateral, ft. (m). ne = number of emitters along the lateral. qa = average emitter flow rate, gph (L/h)

  20. Slope and topography

  21. Four Cases

  22. Lateral Flow flat slope

  23. Lateral Flow 2% downhill slope

  24. Lateral flow 2% uphill slope

  25. Lateral flow varied slope

  26. Manifold spacing • Spacing is a compromise between field geometry and lateral hydraulics • Lateral length is based on allowable pressure - head difference. • Have the same spacing throughout the field in all crops

  27. Manifold Location • More efficient to place in middle • two laterals extend in opposite directions from a common inlet point on a manifold, they are referred to as a pair of laterals. • Manifold placed to equalize flow rates on the uphill and downhill laterals

  28. Manifold placement

  29. Determine optimum lateral length • EU • Slope • Based on friction loss • limited to ½ the allowable pressure difference (ΔPs)

  30. Hydraulics • Limited lateral losses to 0.5DPs • Equation for estimating • Darcy-Weisbach (best) • Hazen-Williams • Watters-Keller (easiest, used in NRCS manuals)

  31. Hazen-Williams equation hf =friction loss (ft) F = multiple outlet factor Q = flow rate (gpm) C = friction coefficient D = inside diameter of the pipe (in) L = pipe length (ft)

  32. Watters-Keller equation hf = friction loss (ft) K = constant (.00133 for pipe < 5” .00100 for > 5”) F = multiple outlet factor L = pipe length (ft) Q = flow rate (gpm) D = inside pipe diameter (in)

  33. Multiple outlet factors

  34. Adjust length for barb and other minor losses

  35. Or Or use equation Where Fe= equivalent length of lateral, ft) K = 0.711 for English units) B = Barb diameter, in D = Lateral diameter, in

  36. Adjusted length L’ = adjusted lateral length (ft) L = lateral length (ft) Se = emitter spacing (ft) fe = barb loss (ft)

  37. Barb loss • More companies are giving a Kdfactor now days

  38. Example Given: lateral 1 diameter 0.50”, qave=1.5gpm,Barb diameter 0.10” lateral 2 diameter 0.50”, qave=1.5gpm, k=.25 Both laterals are 300’ long and emitter spacing is 4 ft Find: equivalent length for lateral 1 and hetotal for lateral 2

  39. Solution Lateral 1 Lateral 2

  40. Practice problem

  41. Procedure • Step 1 - Select a length calculate the friction loss • Step 2 – adjust length to achieve desired pressure difference ( 0.5DHs)

  42. Step 3 - adjust length to fit geometric conditions • Step 4 - Calculate final friction loss • Step 5 – Find inlet pressure • Step 6 – Find minimum pressure

  43. Next step is to determine Δh • Paired Lateral • Single Lateral – • Slope conditions • S > 0 • S = 0 • Slope Conditions • S < 0 and –S > friction slope

  44. Last condition • S < 0 and –S < Friction slope Which ever is greater

  45. Find minimum lateral pressure • Where S > 0 or S=0 • Where S < 0 and –S < Friction slope • Where S < 0 and –S > friction slope

More Related