1 / 63

Extended Office Cabling U-Box

Extended Office Cabling U-Box. Product Manager Roland Beeler 3.5.2007. Agenda. Product description Handling U as in universal/unique Product range Technical data Range of applications Competitors Get more Marketing measures. The U-Box. COMPACT FL XIBILITY.

oria
Download Presentation

Extended Office Cabling U-Box

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Extended Office CablingU-Box Product Manager Roland Beeler 3.5.2007

  2. Agenda • Product description • Handling • U as in universal/unique • Product range • Technical data • Range of applications • Competitors • Get more • Marketing measures

  3. The U-Box COMPACT FL XIBILITY

  4. Product Description

  5. Product Description One box many applications: • 4x45x45 • 3xFLF • 2x10 voice module • 8x data snap-in • 8x power snap-in • 4x45x45 Italia power • Blind • Cable passages for power and data • Other screen options Accessories: • A platform for data, communications and power • Easy planning • Compact size 6qty

  6. Product Description:Fronts Front 4x45x45

  7. Product Description:Fronts Italia power front 4x45x45 • Type Vela, Mosaic • Type Cross

  8. Product Description:Fronts Data snap-in front Keystone cutout for 19.5x14.9mm Voice front 2x10RJ45

  9. Product Description: Fronts Power 8x snap-in front, Wago, Wieland Blind front

  10. Product Description: Fronts Cable passage front • Cable gland 4xM20-25 Simple knock-outs for data and power cables • Knock-out for data and power cables • 5 levels for knock-outs 2-8 data cables

  11. Fronts 4x45x45 3xFLF Blind 8xdata snap-in 2x10 Voice 8xPower snap-in 4x45x45 Power Italia Cable passage Communication/data Generally all 45x45 formats Power

  12. Agenda • Product description • Handling • U as in universal/unique • Product range • Technical data • Range of applications • Competitors • Get more • Marketing measures

  13. Convenient and Quick Installation • Symmetric screen geometry = front is back and back is front • Greater flexibility • Convenient RJ 45 module installation • Can be assembled on both sides = high packing density • Symmetric screens = more flexibility • Easy handling • Convenient module installation • High packing density

  14. Basic Screw Lock • Quarter of a turn to close and open the box • Easy and quick cover installation • Clever screw lock • Quick installation • Additional screw opening for locking (optional) • Screw KA30x10

  15. One Connector – Many Applications • Without raising • Raised to compensate for unevenness • Protected against water, i.e. in airconditioned raised floors

  16. One Connector – Many Applications • Exterior mounting • Pre-terminated boxes, installation without having to remove cover • Stacking • Higher packing density

  17. One Connector – Many Applications • Staggered stacks • Labeling is guaranteed • One connector – more options • Series connector

  18. Cover • Lateral cable knock-outs • 2x5 levels for knock-outs for data and power cables • Screw opening for additional security stacking • Screw KA 30x10 • Lateral entry, greater flexibility • Labeling field for example for P-Touch 13x185 • Stacking recess

  19. Base • Cable gland M20 • Specified integrated mounting, two types of terminal blocks • Controlled strain relief 8x for data cables • Cable tie or Velcro tape • R&M recommends Velcro tape • Recess for better wiring • Dimension diagram for holes 215mm by160mm • Radius limiter mounting for FO, KA 35x10mm

  20. Base • Mounting holes are symmetrically constructed • Tubes for high loads • Mounting e.g. for track or DIN rail • 90° rotation in case of miss-drilling • Secure strain relief • Universal mounting • Terminal block mounting • Spacing holder for voice harmonica • Screw KA30x8 • Prepared recess for dust cover pre-assembly

  21. Base Separation Cover • Standardscompliance separation cover, separating power and data • EN 50174-2:2000 • Transparent cover, control wire guide • Recess for floor mounting • Standardscomplianceseparation

  22. Base FO • Radius limiter for break-out solutions e.g. Varioline • LC duplex connection modules, SC-RJ • FO break-out solution

  23. FO Solution

  24. Agenda • Product description • Handling • U as in universal/unique • Product range • Technical data • Range of applications • Competitors • Get more • Marketing measures

  25. Lateral Entry = High Packing Density • Maintaining cable radii

  26. Data and Power U-Box for Two Workstations Solution for two workstations • Two medias in one box

  27. U-Box as in Universal Data Power Voice distributor Kupfer 45x45 Snap-In FO Home wiring

  28. Are High Loads Feasible with Plastic? • High load at least min 200 kg • High stability PC Lexan 940 • Minor distortion • Meets the highest requirements – EN 60670-1

  29. Fire Load • Low fire load V-0 • Filament test at 960º • Halogen free • Meets highest requirements for public buildings • Lexan 940, UL listed 94V-0 • Low fire load

  30. Agenda • Product description • Handling • U as in universal/unique • Product range • Technical data • Range of applications • Competitors • Get more • Marketing measures

  31. Product range • U-Box housing with front cable passage • Box with base, cover, cable passage screen, 6 connectors 1qty R317073 1qty R317082 • Empty U-Box housing • Box with floor, cover, 6 connectors • Front 4x45x45 • For all installations with 45x45 installation rack 10qty R317074

  32. Product range • Power Italia front 4x45x45 • For mosaic outlets Italia 5qty R317091 R317075 10qty • Front 3xFLF • For all installations with 54x32mm • FLF installation track • Front 8xRJ45 snap-in • For RJ45 snap-in connection modules 10qty R317076

  33. Product range • Front 2x10RJ45 voice modules with 4xKA30x6mm • For 10RJ45 connection modules 5qty R317078 R317077 10qty • Front 8x power snap-in • For snap-in connector • Wago, Wieland • Blind front • For specialized applications R317079 1qty

  34. Product range • Cable passage front • For 4x cable gland M20-M25 • and 2x data passages with 5 levels 10qty R317080 1qty R317081 • Separation cover • Internal cover to separate power and data 1qty • Plug-in terminal strip • Plug-in terminals 5x2.5mm2 • Screwed terminal strip • Screw terminals 5x2.5mm2 R317083 1qty R317084

  35. Agenda • Product description • Handling • U as in universal/unique • Product range • Technical data • Range of applications • Competitors • Get more • Marketing measures

  36. Data Sheet • Standards • Main standard 60670-1 • IEC 60670-22 during operation • IEC 60670-23 Ed.1 during installation • IEC 60884-1 Ed.3 assembled version • EN 50174-2:2000 separation of data and power • CE tested • Size 210x210x57mm • Load at least min 200 kg, EN 60670-1 • Fire load V-O, halogen free • Dust cover IP20 • Filament test at 960º • Material PC Lexan 940 • UL listed, 94V-0 • Color: anthracite RAL 7016

  37. Agenda • Product description • Handling • U as in universal/unique • Product range • Technical data • Range of applications • Competitors • Get more • Marketing measures

  38. = WA 2 connector solution WA WA 1 2 FD MUTO WA 3 WA 3 connector solution WA DB DB DB CP cable cat. 6 1 FD CP 2 ISO 11801, EN 50173-1:2002 Concepts in Horizontal Cabling

  39. Use in Raised Floors Freenet-System with Muto

  40. Use in Raised Floors Freenet-System mit Muto Power-Daten

  41. CP-Kabel xm max 90 m A B D Permanent link CP Length Model for 4-Connector Channel ISO 11801, EN 50173-1:2002 (A+B+CP cable+D) x 1.5 STP, 1.2 UTP + H fixed cable, patch cord≤ 100 m Factor 1.0 for solid conductors, factor 1.5 for flexible conductors Calculation sample for channel length: [(A5m)+(B3m)+(CP cable 5m)+(D1m)]=14m x 1.5=21m + fixed cable 79m=100m Length model for 4-connectors is only feasible with powerful modules

  42. Use in Raised Floors Freenet with CP-Muto FD Changing 40% of APs 12 cubic meters per AP According to BAG Standards help to bring order to the technical infrastructure, (ISO 11801, EN 50173-1:2002)

  43. Consolidation Point (CP) • Easier planning made possible • A furnishing plan is not necessary • Installation is possible in two phases • Phase 1 basic installation • Phase 2 finishing • Improved work distribution • Uniform patch cord length • Installation unrelated to tenant, investment security

  44. Use in Raised Floors Freenet system with CP

  45. Use in Raised Floors with RCO Power • Connector-ready box • No time wasted on construction site • Quick installation • No line interruption • Looping unnecessary • Flexible cabling • Conversion of workstation, cabling also goes • Easy expansion at any point • Plug and work philosophy

  46. Use in Ceilings Freenet system with CP

  47. Use in wall mounted Freenet system with Muto power and data

  48. Use in wall mountedVoice Distributor

  49. Voice Application

  50. HWS «light»

More Related