Changes in FiDeL parameters, pending issues and cross-checks for LHC 2012

Changes in FiDeL parameters, pending issues and cross-checks for LHC 2012. Per Hagen (TE/MSC) FiDeL Team 26.03.2012. Changes in FiDeL parameters for 2012. Correction of some harmonics per circuit MQXB b6 circuit values were random junk (probably a wrong Excel copy & paste)

oro
Download Presentation

Changes in FiDeL parameters, pending issues and cross-checks for LHC 2012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Changes in FiDeL parameters,pending issues and cross-checks for LHC 2012 Per Hagen (TE/MSC) FiDeL Team26.03.2012

  2. Changes in FiDeL parameters for 2012 • Correction of some harmonics per circuit • MQXB b6 circuit values were random junk (probably a wrong Excel copy & paste) • MQXB2.R1 .R2 .R5 a4, b3, b5 wrongly rotated (due to a false assumption in Excel sheet) • Guilty: Per • Discovered when fine-checking circuit versus magnets(in the context of the triplet correction for 2012 final squeeze)

  3. Changes in FiDeL parameters for 2012 • Reducing number of fitting constants to match what LSA can cope with (per circuit) • MBX b3: DCMAG mu now expressed at 300A, like TF • MBX b5: DCMAG mu and RESMAG rho now expressed at 300A • GM_MQXB b6 : DCMAG-I_inj_ref for b6 equal to TF. Rescaled DCMAG-mu to match TF. Changed Ic to match TF (no rescaling possible)

  4. Pending issues in FiDeL parameters! • Massimo Giovannozzi draw my attention to some strange old inconsistency between harmonics for triplets which exists since the first FiDeL parameter set • Discovered when comparing old WISE “collision” data (using “high-field” data extracted from database) with current FiDeL data • Some MQXA harmonics appear rotated: B'(odd) = -B(odd), A'(odd) = -A(odd) for Q3 in tunnel (not all!) • Compatible with “upside-down” rotation • Q1.L8 very different all harmonics • Q1.R2 b6 different • I never thought of making a cross-check between old WISE data and FiDeL Inconvenient Truth

  5. LSA cross-checks for 2012 • LSA beam processes checked • PRECYCLE_4TeV_V1 • RAMP_4TeV_2012_V1 • RAMP_4TeV_MCS_2012_V1 • SQUEEZE_4TeV_2012_V1 • RAMPDOWN_4TeV_V1 • What has been checked • “P2N” : Power Converter limits not exceeded • “P2R” : Pre-cycle versus ramp cycle in “harmony” • “An/Bn”: Subset of FiDeL multipoles used in LSA beam processes • “K” : Optics strengths agree with optics files; constant or F(beta*) • “I” : FiDeL circuit currents agree with K-values • What has NOT been checked • MB b3 and b5 decay during injection (no LSA data) • Arc correctors which strengths are entirely managed by LSA (depends upon optics algorithm not in WISE) • Chromaticity correction during squeeze (sextupole strengths not published in optics squeeze files) • Strengths of optics incorporated in LSA from run-time (orbit & bumps, octupoles)

  6. Results from LSA cross-checks for 2012 • Hard to find issues (wasted time?!) • Pre-cycle • As usual wrong I_MIN in P2N for RD34.LR3. 40A instead of 18A. ACC_SETTINGS_DB does not reflect reality! • Pre-cycle versus ramp (pre-cycle = pre-cycle or ramp-down after physics) • These circuits should have max current increased in pre-cycle to match ramp-down: MQXA, MQXB, RCD, RQF, RQD • RCS should have max current increased in ramp-down to match pre-cycle • These circuits should have max current increased in both pre-cycle and ramp-down to match max current: RD1 cold, RD2 cold, RD3 cold, RD4 cold, probably RMSD, RQ5.L6, RQ5.R6, RQ6.L3, RQ6.L7, RQ6.R3, RQ6.R7

  7. Results from LSA cross-checks for 2012 • Squeeze • RCB K never correspond to official squeeze optics • Some matched optics points not used (just an observation) • Ramp • RCD.A78B1, RCDA78B2 : IMAX exceeded by a few mA • RCBXH1.L1 has only a positive cycle. Expect + and - cycles as for 2011 • Wrong sign found for current in RCBXH3.L8 (polarity wrong in power converter or wiring)

  8. MB b3 / b5 correction • Changes in powering history (2012 versus 2011): • Flat-top current increased: 6000 A -> 6740 A • But as we agreed on disabling FiDeL MB b3 energy scaling of amplitude in 2011: MB b3 snapback unchanged • MB b5 • 10% different from WISE during first 30 seconds (see next slide) • after that perfect agreement • WISE has currently MB b5 energy scaling of amplitude disabled (as for MB b3). Right or wrong?

  9. Ongoing cross-check activity • Correction of IP optics using triplet correctors • Errors in triplets and D1 important when IPs -> fully squeezed • Depends upon optics algorithm not in WISE (LHC project note 349) so do it from scratch • Reference implementation in Fortran by SF • Limited success yet for myself (I used thick lens instead of thin lens) and the algorithm is very sensitive to changes in betatron functions • In this context the question about inconsistent values for triplet harmonics, old WISE versus FiDeL has been raised (mentioned earlier in presentation)