TEST INCIDENT REPORT 9 July 2018. Test Title: Test Project: SSD-PPTA-002 Interoperability with Firebird UAV TIR #: 46/JRATS/002-01/Critical Test Agency: Test Sponsor: PM, JRATS 46 Test Wing Eglin AFB, FL Model: JUGV, PPTA #4 Serial no: PPTA01-0004

parley
Download Presentation

TEST INCIDENT REPORT 9 July 2018

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TEST INCIDENT REPORT 9 July 2018 Test Title: Test Project: SSD-PPTA-002 Interoperability with Firebird UAV TIR #: 46/JRATS/002-01/Critical Test Agency: Test Sponsor: PM, JRATS 46 Test Wing Eglin AFB, FL Model: JUGV, PPTA #4 Serial no: PPTA01-0004 Mfr: Prime Contractor ID Contract #: Post MS B R&D-JRATS-01/002 Incident Data Title: Aimpoint error Date/Time: 7/8/18 1705 EST Incident class: Major Chargeability: Hardware/Software Observed During: Operation Incident status: Preliminary Action: Data analysis Categories: Engr, RAM, SW Test Environment: Hilly Cross Country Conditions: Day, bright, sunny light wind Maintenance Data Diagnostic manhours: Level used: Unit Active maint clockhours: Component: Engine Diagnostic manhours: Level used: Unit Active maint manhours: Component: Battery Diagnostic manhours: Level used: Unit Active maint manhours: Component:Transmission Diagnostic manhours: Level used: Unit Active maint manhours: Component: Controller Calculated MTBM: Engine(80); Battery (2000); Transmission (400); Controller (500) Calculated MMT: Engine(8); Battery (2); Transmission (10); Controller (3) Incident/Maintenance Description Test article required drive train maintenance enroute to designated target location. The missile used an erroneous aim point and attacked the JUGV test article instead of the target. It is not certain yet whether the JUGV provided an initial incorrect aimpoint or whether the correct aimpoint was changed during data transfer along the JUGV-JCCS-Firebird-Wildfire data chain. Corrective Action CA status: Active CA start:TBD CA end:TBD Version 3.0, 1-14-14

More Related