INDOT Culvert Sizing Policy Purdue Road School March 9, 2011

INDOT Culvert Sizing Policy Purdue Road School March 9, 2011. Your Presenters:. John Bartolo, PE & Crystal Weaver, PE INDOT Office of Hydraulics. The Goal for Policy is a Clear Understanding!. Design Storm Frequency. Allowable Headwater New Alignment. 0.14 ft. Maximum Backwater

patty
Download Presentation

INDOT Culvert Sizing Policy Purdue Road School March 9, 2011

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. INDOT Culvert Sizing Policy Purdue Road School March 9, 2011

  2. Your Presenters: John Bartolo, PE & Crystal Weaver, PE INDOT Office of Hydraulics

  3. The Goal for Policy is a Clear Understanding!

  4. Design Storm Frequency

  5. Allowable Headwater New Alignment • 0.14 ft. Maximum Backwater • Special Cases: • Backwater Dissipates 0.14 ft. or Less at R/W • Backwater is Contained in the Channel • Remember to Check Outlet Velocity! • Flood easements are purchased • Very rare and only on large projects

  6. Allowable HeadwaterReplacing an Existing Culvert • Match or Reduce Existing Backwater • Exception: • Existing Backwater Exceeds 1 ft.

  7. Allowable HeadwaterOther Constraints • Grade of Adjacent Driveways • Finished Floor Elevation of Adjacent Buildings • Elevation of Surrounding Crop Land

  8. Allowable HeadwaterOther Constraints

  9. Roadway Serviceability • For a Q100 Design Storm • 2 ft. Below Edge of Pavement • For Design Storms Less Than Q100 • Headwater Can Not Exceed Edge of Pavement

  10. Maximum Outlet Velocity • Revetment Riprap < 6.5 ft/s • Class 1 Riprap > 6.5 ft/s < 10 ft/s • Class 2 Riprap > 10 ft/s < 13 ft/s • Energy Dissipator > 13 ft/s • See Chapter 34 in the Indiana Design Manual

  11. Minimum Outlet Velocity • Typical Minimum Outlet Velocity • 3 ft/s

  12. Do Not Consider Storage at the Culvert

  13. Priority System • Trial 1 - Single Circular Pipe • Trial 2 - Single Deformed Pipe • Trial 3 - Single Specialty Structure • Trial 4 - Multiple Circular Pipes • Trial 5 - Multiple Deformed Pipes • Trial 6 - Multiple Specialty Structures

  14. Pipe Culvert Interior Designation • Smooth Interior: • Manning’s n = 0.012 • Corrugated Interior: • Manning’s n = 0.024

  15. Minimum Culvert Size

  16. Culvert Extension Process • Match Existing Culvert Size and Type • Perform Appropriate Hydraulic Analysis

  17. Culvert SumpingThree Sided Structures • Sump structure • 18 inches for sand • 12 inches for other soils • 3 inches for rock or till • Structure should not increase in size • See standard drawing for stream bed and scour information

  18. Culvert SumpingBoxes and Pipes

  19. Culvert SumpingBoxes and Pipes • Structure may increase in size, if sump is more than 3 inches • Hydraulic modeling may be needed to check capacity.

  20. Approved Design Methods • Computer Method • FHWA Program HY-8 • Hand Method • Nomographs From FHWA Publication HDS #5 “Hydraulic Design of Highway Culverts” • Available as a Printed Manual, on CD ROM or online

  21. Design Responsibility • All Types of Projects • Consultant Will Size the Culvert(s) • INDOT Hydraulics Will Review Computations

  22. Where Do I Get More Information? • INDOT Design Manual Part IV Hydrology and Hydraulics • FHWA Hydraulics Home Page • Hydraulics Engineering Publication List • Hydraulics Engineering Software Reference List • www.fhwa.dot.gov/engineering/hydraulics/

  23. Questions www.fhwa.dot.gov/engineering/hydraulics/